• Shopping Cart
    There are no items in your cart

IEC 60335-2-104:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Household and similar electrical appliances - Safety - Part 2-104: Particular requirements for appliances to recover and/or recycle refrigerant from air conditioning and refrigeration equipment

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

31-12-2021

Language(s)

English, English - French

Published date

15-01-2003

€280.71
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General requirement
5 General conditions for the tests
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at operating
   temperature
14 Transient overvoltages
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers and associated
   circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation
30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
Annexes
Annex AA (normative) Vacuum levels
Annex BB (normative) Particulate used in standard
         contaminated refrigerant
Annex CC (normative) Compatibility requirements
Annex DD (normative) Requirements for swelling oil
Bibliography
Figures
Tables

Deals with the safety of electrical appliances to recover and/or recycle refrigerant from air conditioning and refrigeration equipment incorporating open drive or motor-compressors. The maximum rated voltage being not more than 250V for single phase appliances and 600V for all other appliances.

Committee
TC 61/SC 61D
DevelopmentNote
To be used in conjunction with IEC 60335-1. (01/2003) Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
43
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
GOST IEC 60335-2-104 : 2013 Identical

I.S. EN 378-4:2016 REFRIGERATING SYSTEMS AND HEAT PUMPS - SAFETY AND ENVIRONMENTAL REQUIREMENTS - PART 4: OPERATION, MAINTENANCE, REPAIR AND RECOVERY
BS EN 378-4:2016 Refrigerating systems and heat pumps. Safety and environmental requirements Operation, maintenance, repair and recovery
13/30291780 DC : 0 BS EN 378-4 - REFRIGERATING SYSTEMS AND HEAT PUMPS - SAFETY AND ENVIRONMENTAL REQUIREMENTS - PART 4: OPERATION, MAINTENANCE, REPAIR AND RECOVERY
UNE-EN 378-4:2017 Refrigerating systems and heat pumps - Safety and environmental requirements - Part 4: Operation, maintenance, repair and recovery
EN 378-4:2016 Refrigerating systems and heat pumps - Safety and environmental requirements - Part 4: Operation, maintenance, repair and recovery
PREN 378-4 : DRAFT 2013 REFRIGERATING SYSTEMS AND HEAT PUMPS - SAFETY AND ENVIRONMENTAL REQUIREMENTS - PART 4: OPERATION, MAINTENANCE, REPAIR AND RECOVERY
ISO 5149-4:2014 Refrigerating systems and heat pumps — Safety and environmental requirements — Part 4: Operation, maintenance, repair and recovery

CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60252:1993 A.C. motor capacitors
IEC 60320-1:2015 Appliance couplers for household and similar general purposes - Part 1: General requirements
IEC 60238:2016+AMD1:2017 CSV Edison screw lampholders
IEC 60738-1:2006+AMD1:2009 CSV Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60950:1999 Safety of information technology equipment
ISO 5149:1993 Mechanical refrigerating systems used for cooling and heating Safety requirements
CISPR 14-2:2015 RLV Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
IEC 60320-2-3:1998+AMD1:2004 CSV Appliance couplers for household and similar general purposes - Part 2-3: Appliance couplers with a degree of protection higher than IPX0
ISO 1463:2003 Metallic and oxide coatings Measurement of coating thickness Microscopical method
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 60695-2-13:2010+AMD1:2014 CSV Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 60249-2-4:1987 Base materials for printed circuits. Part 2: Specifications. Specification No. 4: Epoxide woven glass fabric copper-clad laminated sheet, general purpose grade
IEC 60249-2-5:1987 Base materials for printed circuits. Part 2: Specifications. Specification No. 5: Epoxide woven glass fabric copper-clad laminated sheet of defined flammability (vertical burning test)
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60051-2:1984 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 2: Special requirements for ammeters and voltmeters
IEC 61180-2:1994 High-voltage test techniques for low-voltage equipment - Part 2: Test equipment
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
IEC 60335-2-34:2012+AMD1:2015+AMD2:2016 CSV Household and similar electrical appliances - Safety - Part 2-34:Particular requirements for motor-compressors
IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
IEC 61643-1:2005 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 9772:2012 Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame
IEC 61058-1:2016 Switches for appliances - Part 1: General requirements
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC 60061-1:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
IEC 60906-1:2009 IEC system of plugs and socket-outlets for household and similar purposes - Part 1: Plugs and socket-outlets 16 A 250 V a.c.
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
ISO 2178:2016 Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method
IEC 60335-2-29:2016 Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60998-2-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
IEC 60990:2016 Methods of measurement of touch current and protective conductor current
IEC 60730-1:2013+AMD1:2015 CSV Automatic electrical controls - Part 1: General requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.