IEC 60364-7-713:2013
Current
The latest, up-to-date edition.
Low-voltage electrical installations - Part 7-713: Requirements for special installations or locations - Furniture
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
06-02-2013
FOREWORD
INTRODUCTION
713 Furniture
713.1 Scope
713.2 Normative references
713.3 Terms and definitions
713.41 Protection for safety - Protection against
electric shock
713.415 Additional protection
713.52 Selection and erection of electrical equipment -
Wiring systems
713.55 Selection and erection of electrical equipment -
Other equipment
Annex A (informative) - List of notes concerning
certain countries
Bibliography
IEC 60364-7-713:2013 applies to the wiring system of furniture (and similar fitments) which is connected to the electrical installation. Examples are beds, cupboards, desks and shop display cases, in which electrical equipment such as luminaires, installation couplers according to IEC 61535, socket-outlets, switching devices and wiring systems are installed. This second edition cancels and replaces the first edition, published in 1996, and constitutes a technical revision. This edition includes changes to the scope: the requirements of Part 7-713 now apply to electrical equipment of furniture connected to a supply with a nominal voltage UO not exceeding 230 V and a total load current not exceeding 32 A, including three-phase 32 A supplies. This new edition makes reference to Part 4-41 additional protection and requires that the fixed circuit is protected by an RCD with a rated residual operating current not exceeding 30 mA.
Committee |
TC 64
|
DevelopmentNote |
Stability Date: 2020. (02/2013)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS C 0364-7-713:1999 | Identical |
UNE-IEC 60364-7-713:2015 | Identical |
PN IEC 60364-7-713 : 2017 | Identical |
NEN 1010-7 : 2000 AMD 3 2005 | Identical |
UNE 20460-7-713:2002 | Identical |
EN 61535:2009/A1:2013 | INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS (IEC 61535:2009/A1:2012) |
BS EN 61535 : 2009 | INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS |
I.S. EN 61535:2009 | INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS (IEC 61535:2009 (EQV)) |
IEC 61024-1-2:1998 | Protection of structures against lightning - Part 1-2: General principles - Guide B - Design, installation, maintenance and inspection of lightning protection systems |
IEC 61991:2000 | Railway applications - Rolling stock - Protective provisions against electrical hazards |
UNE-EN 61535:2010 | Installation couplers intended for permanent connection in fixed installations |
CSA ISO/IEC 18010 :2004 | INFORMATION TECHNOLOGY - PATHWAYS AND SPACES FOR CUSTOMER PREMISES CABLING |
IEC 61535:2009+AMD1:2012 CSV | Installation couplers intended for permanent connection in fixedinstallations |
CSA ISO/IEC 18010 : 2004 : INC : AMD 1 : 2006 : R2012 | INFORMATION TECHNOLOGY - PATHWAYS AND SPACES FOR CUSTOMER PREMISES CABLING |
ISO/IEC 18010:2002 | Information technology Pathways and spaces for customer premises cabling |
18/30364809 DC : DRAFT MAR 2018 | BS EN 61535 - INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS |
IEC 60245-1:2003+AMD1:2007 CSV | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements |
IEC 60670-1:2015 | Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements |
IEC 60227-3:1993+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring |
IEC 60364-7-701:2006 | Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower |
IEC 60245-4:2011 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables |
IEC 61535:2009+AMD1:2012 CSV | Installation couplers intended for permanent connection in fixedinstallations |
IEC 62440:2008 | Electric cables with a rated voltage not exceeding 450/750 V - Guide to use |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.