FOREWORD
INTRODUCTION
715 Extra-low-voltage lighting installations
715.1 Scope
715.2 Normative references
715.4 Protection for safety
715.41 Protection against electric shock
715.414 Protective measure: extra-low-voltage provided
            by SELV and PELV
715.42 Protection against thermal effects
715.422.3 Locations with risks of fire due to the nature
            of processed or stored materials
715.422.106 Fire risk of transformers/convertors
715.422.107 Fire risk due to short-circuit
715.43 Protection against overcurrent
715.430.104 Protection against overcurrent in ELV lighting
            installations
715.5 Selection and erection of electrical equipment
715.52 Wiring systems
715.521 Types of wiring system
715.521.106 Bare conductors
715.521.107 Suspended systems
715.523 Current-carrying capacities
715.524 Cross-sectional areas of conductors
715.525 Voltage drop in consumers' installations
715.53 Isolation, switching and control
715.530.3 General and common requirements
715.536 Isolation and switching
Annex A (informative) - List of notes concerning certain
        countries
Bibliography

IEC 60364-5-55:2011 The particular requirements apply to extra-low-voltage lighting installations supplied from sources with a maximum rated voltage of 50 V a.c. or 120 V d.c. For the definition of an extra-low voltage lighting system reference should be made to IEC 60598-2-23. This second edition cancels and replaces the first edition, published in 1999, and constitutes a technical revision. The major technical changes with respect to the previous edition are:
- the clause numbering is aligned with the present structure of IEC 60364;
- references to LED modules and their particular installation requirements have been introduced;
- and requirements for cross-sectional area of conductors are modified.

Committee
TC 64
DevelopmentNote
Stability Date: 2021. (10/2012)
DocumentType
Standard
Pages
24
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
JIS C 0364-7-715:2002 Identical
DIN VDE 0100-715 : 2014-02 Identical
VDE 0100-715 : 2014-02 Identical
UNE-HD 60364-7-715:2013 Identical
UNE 20460-7-715:2006 Identical

EN 62838:2016/AC:2017-11 LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS
HD 60364-5-52:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
I.S. EN 62838:2016 LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS
IEC 61991:2000 Railway applications - Rolling stock - Protective provisions against electrical hazards
IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
I.S. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
13/30281739 DC : 0 BS EN 62838 - SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATION
S.R. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
BS EN 62838:2016 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. Safety specifications
BS EN 50491-3:2009 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) Electrical safety requirements
UNE-EN 62838:2016 LEDsi lamps for general lighting services with supply voltages not exceeding 50 v a.c. r.m.s. or 120 v ripple free D.C. - Safety specifications
UNE-EN 50491-3:2010 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements
I.S. EN 50491-3:2009 GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 3: ELECTRICAL SAFETY REQUIREMENTS
EN 50491-3:2009 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements
UNE-HD 60364-5-52:2014 Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
IEC 60598-2-23:1996+AMD1:2000 CSV Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps
IEC 61347-2-13:2014+AMD1:2016 CSV Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
IEC 60570:2003+AMD1:2017 CSV Electrical supply track systems for luminaires
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
IEC 61347-2-2:2011 Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment
AS/NZS 62838:2020 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. - Safety specifications (IEC 62838:2015 (ED.1.0)/COR1:2017, MOD)
IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
IEC 60998-2-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.