IEC 60598-2-3:2002+AMD1:2011 CSV
Current
The latest, up-to-date edition.
Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
17-11-2011
Foreword
3.1 Scope
3.2 General test requirements
3.3 Definitions
3.4 Classification of luminaires
3.5 Marking
3.6 Construction
3.7 Creepage distances and clearances
3.8 Provision for earthing
3.9 Terminals
3.10 External and internal wiring
3.11 Protection against electric shock
3.12 Endurance tests and thermal tests
3.13 Resistance to dust and moisture
3.14 Insulation resistance and electric strength
3.15 Resistance to heat, fire and tracking
Annex A (informative) Drag coefficient measurement
Annex B (normative) Schedule of amended clauses containing
more serious/critical requirements which require
products to be retested
IEC 60598-2-3:2002+A1:2011 specifies requirements for:
- luminaires for road, street lighting and other public outdoor lighting applications;
- tunnel lighting;
- column-integrated luminaires with a minimum total height above normal ground level of 2,5 m;
- and for use with electrical lighting sources on supply voltages not exceeding 1 000 V.
This publication is to be read in conjunction with IEC 60598-1:2008.
This consolidated version consists of the third edition (2002) and its amendment 1 (2011) and has been prepared for user convenience. Therefore, no need to order amendment in addition to this publication.
Committee |
TC 34/SC 34D
|
DevelopmentNote |
To be read in conjunction with IEC 60598-1. (11/2011) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60598-2-3 : 2003 AMD 1 2011 | Identical |
GOST IEC 60598-2-3 : 2012 | Identical |
NEN EN IEC 60598-2-3 : 2003 AMD 1 2011 | Identical |
I.S. EN 60598-2-3:2005 | Identical |
PN EN 60598-2-3 : 2006 AMD 1 2012 | Identical |
SAC GB 7000-203 : 2014 | Identical |
SN EN 60598-2-3 : 2003 | Identical |
DIN EN 60598-2-3 : 2011 | Identical |
VDE 0711-2-3 : 2011 | Identical |
VDE 0711-203 : 96 AMD 1 97 | Identical |
EN 60598-2-3:2003/A1:2011 | Identical |
UNE-EN 60598-2-3:2003 | Identical |
UNE 20447-2-3:1986 | Identical |
NEN 10598-2-3 : 94 AMD 1 1997 | Identical |
BS 4533-102.3(1981) : AMD 4650 | Identical |
EN 62722-2-1:2016 | Luminaire performance - Part 2-1: Particular requirements for LED luminaires |
DD CEN/TS 14383-3:2005 | Prevention of crime. Urban planning and building design Dwellings |
S.R. CEN/TS 14383-3:2005 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS |
UNE-EN 62722-2-1:2016 | Luminaire performance - Part 2-1: Particular requirements for LED luminaires |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
CCS GUIDELINE E-08 : 2017 | LUMINAIRES |
S.R. CEN TR 14383-8:2009 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 8: PROTECTION OF BUILDINGS AND SITES AGAINST CRIMINAL ATTACKS WITH VEHICLES |
EN 60598-1:2015/A1:2018 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNI CEN/TS 14383-3 : 2006 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS |
UNE-CEN/TR 14383-8:2011 IN | Prevention of crime - Urban planning and building design - Part 8: Protection of buildings and sites against criminal attacks with vehicles |
BS EN 60598-1:2015 | Luminaires General requirements and tests |
CEN/TR 14383-8:2009 | Prevention of crime - Urban planning and building design - Part 8: Protection of buildings and sites against criminal attacks with vehicles |
I.S. EN 60598-1:2015 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
I.S. EN 62722-2-1:2016 | LUMINAIRE PERFORMANCE - PART 2-1: PARTICULAR REQUIREMENTS FOR LED LUMINAIRES |
UNE-EN 60598-1:2015 | Luminaires - Part 1: General requirements and tests |
12/30266672 DC : 0 | BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 62722-2-1:2016 | Luminaire performance Particular requirements for LED luminaires |
UNE-CEN/TS 14383-3:2011 EX | Prevention of crime - Urban planning and building design - Part 3: Dwellings |
CEN/TS 14383-3:2005 | Prevention of crime - Urban planning and building design - Part 3: Dwellings |
CSA E61347.1 :2003 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
CSA E61347.1 : 2003 : R2013 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
CSA E60598.1 : 2016 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
ISO 4354:2009 | Wind actions on structures |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60364-7-714:2011 | Low-voltage electrical installations - Part 7-714: Requirements for special installations or locations - External lighting installations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.