IEC 60730-2-3:2006
Current
The latest, up-to-date edition.
Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
11-10-2006
FOREWORD
1 Scope and normative references
2 Definitions
3 General requirements
4 General notes on tests
5 Rating
6 Classification
7 Information
8 Protection against electric shock
9 Provision for protective earthing
10 Terminals and terminations
11 Constructional requirements
12 Moisture and dust resistance
13 Electric strength and insulation resistance
14 Heating
15 Manufacturing deviation and drift
16 Environmental stress
17 Overload, endurance and limited short-circuit
18 Mechanical strength
19 Threaded parts and connections
20 Creepage distances, clearances and distances through
solid insulation
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
23 Electromagnetic compatibility (EMC) requirements - emission
24 Components
25 Normal operation
26 Electromagnetic compatibility (EMC) requirements - immunity
27 Abnormal operation
28 Guidance on the use of electronic disconnection
Annexes
Annex C (normative) Cotton used for mercury switch test
Annex E (normative) Circuit for measuring leakage current
This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1.
Committee |
TC 72
|
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
29
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CSA E60730-2-3:20 | Identical |
NF EN 60730-2-3 : 2008 | Identical |
GOST IEC 60730-2-3 : 2014 | Identical |
SN EN 60730-2-3 : 1993 AMD 11 2005 | Identical |
VDE 0631-2-3 : 2008-06 | Identical |
DIN EN 60730-2-3 : 2008-06 | Identical |
UNE-EN 60730-2-3:2008 | Identical |
CEI EN 60730-2-3 : 2008 | Identical |
NEN EN 60730-2-3 : 1994 | Identical |
BS EN 60922:1997 | Auxiliaries for lamps. Ballasts for discharge lamps (excluding tubular fluorescent lamps). General and safety requirements |
DIN EN 60922 : 1997 | AUXILIARIES FOR LAMPS - BALLASTS FOR DISCHARGE LAMPS (EXCLUDING TUBULAR FLUORESCENT LAMPS) - GENERAL AND SAFETY REQUIREMENTS |
I.S. EN 61347-1:2015 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
11/30252196 DC : 0 | BS EN 61347-1:2008 + A2 - LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
BS EN 61347-1:2015 | Lamp controlgear General and safety requirements |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
DIN EN 60928 : 2000 | AUXILIARIES FOR LAMPS - A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
IEC 61046:1993 | D.C. or a.c. supplied electronic step-down convertors for filament lamps - General and safety requirements |
DIN EN 61046 : 1995 AMD 1 1997 | D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
VDE 0712-22 : 2000 | AUXILIARIES FOR LAMPS - A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
I.S. EN 61347-2-1:2004 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) |
UNE-EN 61347-1:2016 | Lamp controlgear - Part 1: General and safety requirements |
04/300396 DC : DRAFT JAN 2004 | IEC 61347-1 A2 ED.1 - LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
CEI EN 61347-1 : 2016 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
BS EN 60920:1991 | Ballasts for tubular fluorescent lamps. General and safety requirements |
IEC 60928:1995+AMD1:1999 CSV | Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - General and safety requirements |
IEC 60922:1997 | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
PD CLC/TR 50455:2008 | List of interpretations on the EN 60730 series \'Automatic electrical controls for household and similar use\' |
DIN EN 60920 : 1993 AMD 11 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
CLC/TR 50455:2008 | List of interpretations on the EN 60730 series "Automatic electrical controls for household and similar use" |
S.R. CLC/TR 50455:2008 | LIST OF INTERPRETATIONS ON THE EN 60730 SERIES "AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE" |
EN 61046:1994/A1:1996 | D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTERS FOR FILAMENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
EN 60928:1995/A1:1999 | AUXILIARIES FOR LAMPS - A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
EN 60922:1997 | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements |
EN 61347-2-1:2001/A2:2014 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) (IEC 61347-2-1:2000/A2:2013) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.