IEC 60866:1987
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
23-08-2007
IEC 62127-1:2007+AMD1:2013 CSV
IEC 62127-2:2007+AMD1:2013+AMD2:2017 CSV
IEC 62127-3:2007+AMD1:2013 CSV
English - French
15-05-1987
Contents
Foreword
Preface
List of Symbols
Clause
1. Scope
2. Object
3. Definitions
3.1 Free field
3.2 Far field
3.3 Acoustic centre
3.4 Hydrophone (or receiver)
3.5 Reversible transducer
3.6 Reciprocal transducer
3.7 Open-circuit voltage at a hydrophone
3.8 Free-field sensitivity of a hydrophone
3.9 Free-field sensitivity level
3.10 Transmitting response to current of a projector
3.11 Reciprocity coefficient
3.12 Directional response of a hydrophone
3.13 End-of-cable leakage resistance
3.14 Mechanical Q of hydrophone element
4. General introduction
4.1 Choice of measurement method
4.2 Basis of recommendations
4.3 Effect of the finite size of hydrophones
4.4 Hydrophone calibration
5. Hydrophone characteristics
5.1 Sensitivity
5.2 Directivity
5.3 Electrical characteristics
5.4 Mechanical characteristics
6. Specification of performance of a hydrophone
6.1 Free-field voltage sensitivity
6.2 Directivity
6.3 Electrical aspects
6.4 Mechanical and environmental aspects
7. Hydrophone calibration
7.1 Reciprocity techniques
7.2 Principle of the two-transducer reciprocity method
7.3 Calibration measurement conditions
7.4 Experimental method
7.5 Calculation of results
7.6 Accuracy
Appendix A - Rationale for the reciprocity procedure
Appendix B - Plane wave reciprocity
Appendix C - Details of the recommended experimental
procedures
Appendix D - Evaluation of the correction factor, k
Appendix E - Bibliography
Figures
Relates to hydrophones, employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic medical equipment operating in the frequency range 0.5 MHz to 15 MHz. Covers the design and performance requirements of standard hydrophones and the data required to specify their characteristics, and defines a standard method for the measurement of the sensitivity of such hydrophones.Defines the performance characteristics that are required of hydrophones intended for use in a specified range of applications over the frequency band from 0.5 MHz to 15 MHz, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for the specification of the performance of these hydrophones. Describes a standardized procedure for their calibration.
DevelopmentNote |
Also numbered as BS 7041(1989) (09/2005)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN 10866 : 1988 | Identical |
I.S. EN 61102:1994 | MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ |
CEI EN 60565 : 2007 | UNDERWATER ACOUSTICS - HYDROPHONES - CALIBRATION IN THE FREQUENCY RANGE 0,01 HZ TO 1 MHZ |
04/30115966 DC : DRAFT JUL 2004 | |
I.S. EN 60565:2007 | UNDERWATER ACOUSTICS - HYDROPHONES - CALIBRATION IN THE FREQUENCY RANGE 0,01 HZ TO 1 MHZ |
I.S. EN 61846:1999 | ULTRASONICS - PRESSURE PULSE LITHOTRIPTERS - CHARACTERISTICS OF FIELDS |
EN 62092:2001 | Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
EN 61846:1998 | Ultrasonics - Pressure pulse lithotripters - Characteristics of fields |
EN 60500:2017 | Underwater acoustics - Hydrophones - Properties of hydrophones in the frequency range 1 Hz to 500 kHz |
BS EN 61102:1994 | Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz |
IEC 60500:2017 | Underwater acoustics - Hydrophones - Properties of hydrophones in the frequency range 1 Hz to 500 kHz |
IEC 61101:1991 | The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0.5 MHz to 15 MHz |
BS EN 60500:2017 | Underwater acoustics. Hydrophones. Properties of hydrophones in the frequency range 1 Hz to 500 kHz |
I.S. EN 61266:1997 | ULTRASONICS - HAND-HELD PROBE DOPPLER FOETAL HEARTBEAT DETECTORS - PERFORMANCE REQUIREMENTS AND METHODS OF MEASUREMENT AND REPORTING |
07/30161032 DC : 0 | BS EN 61391-2 - ULTRASONICS - PULSE ECHO SCANNERS - PART 2: TECHNIQUES FOR MEASUREMENT OF MAXIMUM DEPTH OF VISUALIZATION AND THE DISPLAYED DYNAMIC RANGE |
BS EN 62092:2002 | Ultrasonics. Hydrophones. Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
PD IEC/TS 62903:2018 | Ultrasonics. Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method |
I.S. EN 61101:1994 | THE ABSOLUTE CALIBRATION OF HYDROPHONES USING THE PLANAR SCANNING TECHNIQUE IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ |
IEC TR 62649:2010 | Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices |
CEI EN 61847 : 1999 | ULTRASONICS - SURGICAL SYSTEMS - MEASUREMENT AND DECLARATION OF THE BASIC OUTPUT CHARACTERISTICS |
IEC TS 62903:2018 | Ultrasonics - Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method |
I.S. EN 60500:2017 | UNDERWATER ACOUSTICS - HYDROPHONES - PROPERTIES OF HYDROPHONES IN THE FREQUENCY RANGE 1 HZ TO 500 KHZ |
BS EN 61846:1999 | Ultrasonics. Pressure pulse lithotripters. Characteristics of fields |
BS EN 61847:1998 | Ultrasonics. Surgical systems. Measurement and declaration of the basic output characteristics |
CEI EN 61846 : 1999 | ULTRASONICS - PRESSURE PULSE LITHOTRIPTERS - CHARACTERISTICS OF FIELDS |
05/30141146 DC : DRAFT OCT 2005 | |
CEI EN 61266 : 1998 | ULTRASONICS - HAND-HELD PROBE DOPPLER FOETAL HEARTBEAT DETECTORS - PERFORMANCE REQUIREMENTS AND METHODS OF MEASUREMENT AND REPORTING |
IEC 60565:2006 | Underwater acoustics - Hydrophones - Calibration in the frequency range 0,01 Hz to 1 MHz |
IEC 61846:1998 | Ultrasonics - Pressure pulse lithotripters - Characteristics of fields |
IEC 61266:1994 | Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting |
BS EN 60565:2007 | Underwater acoustics. Hydrophones. Calibration in the frequency range 0,01 Hz to 1 MHz |
BS EN 61101:1994 | Specification for absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz |
IEC 62092:2001 | Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
EN 60565:2007 | Underwater acoustics - Hydrophones - Calibration in the frequency range 0,01 Hz to 1 MHz |
EN 61266:1995 | Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting |
EN 61102:1993/A1:1994 | MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ |
EN 61101:1993 | The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.