IEC 60866:1987

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

23-08-2007

Language(s)

English - French

Published date

15-05-1987

€197.53
Excluding VAT

Contents
Foreword
Preface
List of Symbols
Clause
1. Scope
2. Object
3. Definitions
    3.1 Free field
    3.2 Far field
    3.3 Acoustic centre
    3.4 Hydrophone (or receiver)
    3.5 Reversible transducer
    3.6 Reciprocal transducer
    3.7 Open-circuit voltage at a hydrophone
    3.8 Free-field sensitivity of a hydrophone
    3.9 Free-field sensitivity level
    3.10 Transmitting response to current of a projector
    3.11 Reciprocity coefficient
    3.12 Directional response of a hydrophone
    3.13 End-of-cable leakage resistance
    3.14 Mechanical Q of hydrophone element
4. General introduction
    4.1 Choice of measurement method
    4.2 Basis of recommendations
    4.3 Effect of the finite size of hydrophones
    4.4 Hydrophone calibration
5. Hydrophone characteristics
    5.1 Sensitivity
    5.2 Directivity
    5.3 Electrical characteristics
    5.4 Mechanical characteristics
6. Specification of performance of a hydrophone
    6.1 Free-field voltage sensitivity
    6.2 Directivity
    6.3 Electrical aspects
    6.4 Mechanical and environmental aspects
7. Hydrophone calibration
    7.1 Reciprocity techniques
    7.2 Principle of the two-transducer reciprocity method
    7.3 Calibration measurement conditions
    7.4 Experimental method
    7.5 Calculation of results
    7.6 Accuracy
Appendix A - Rationale for the reciprocity procedure
Appendix B - Plane wave reciprocity
Appendix C - Details of the recommended experimental
             procedures
Appendix D - Evaluation of the correction factor, k
Appendix E - Bibliography
Figures

Relates to hydrophones, employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic medical equipment operating in the frequency range 0.5 MHz to 15 MHz. Covers the design and performance requirements of standard hydrophones and the data required to specify their characteristics, and defines a standard method for the measurement of the sensitivity of such hydrophones.Defines the performance characteristics that are required of hydrophones intended for use in a specified range of applications over the frequency band from 0.5 MHz to 15 MHz, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for the specification of the performance of these hydrophones. Describes a standardized procedure for their calibration.

DevelopmentNote
Also numbered as BS 7041(1989) (09/2005)
DocumentType
Standard
Pages
58
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
NEN 10866 : 1988 Identical

I.S. EN 61102:1994 MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ
CEI EN 60565 : 2007 UNDERWATER ACOUSTICS - HYDROPHONES - CALIBRATION IN THE FREQUENCY RANGE 0,01 HZ TO 1 MHZ
04/30115966 DC : DRAFT JUL 2004
I.S. EN 60565:2007 UNDERWATER ACOUSTICS - HYDROPHONES - CALIBRATION IN THE FREQUENCY RANGE 0,01 HZ TO 1 MHZ
I.S. EN 61846:1999 ULTRASONICS - PRESSURE PULSE LITHOTRIPTERS - CHARACTERISTICS OF FIELDS
EN 62092:2001 Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz
EN 61846:1998 Ultrasonics - Pressure pulse lithotripters - Characteristics of fields
EN 60500:2017 Underwater acoustics - Hydrophones - Properties of hydrophones in the frequency range 1 Hz to 500 kHz
BS EN 61102:1994 Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz
IEC 60500:2017 Underwater acoustics - Hydrophones - Properties of hydrophones in the frequency range 1 Hz to 500 kHz
IEC 61101:1991 The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0.5 MHz to 15 MHz
BS EN 60500:2017 Underwater acoustics. Hydrophones. Properties of hydrophones in the frequency range 1 Hz to 500 kHz
I.S. EN 61266:1997 ULTRASONICS - HAND-HELD PROBE DOPPLER FOETAL HEARTBEAT DETECTORS - PERFORMANCE REQUIREMENTS AND METHODS OF MEASUREMENT AND REPORTING
07/30161032 DC : 0 BS EN 61391-2 - ULTRASONICS - PULSE ECHO SCANNERS - PART 2: TECHNIQUES FOR MEASUREMENT OF MAXIMUM DEPTH OF VISUALIZATION AND THE DISPLAYED DYNAMIC RANGE
BS EN 62092:2002 Ultrasonics. Hydrophones. Characteristics and calibration in the frequency range from 15 MHz to 40 MHz
PD IEC/TS 62903:2018 Ultrasonics. Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method
I.S. EN 61101:1994 THE ABSOLUTE CALIBRATION OF HYDROPHONES USING THE PLANAR SCANNING TECHNIQUE IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ
IEC TR 62649:2010 Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices
CEI EN 61847 : 1999 ULTRASONICS - SURGICAL SYSTEMS - MEASUREMENT AND DECLARATION OF THE BASIC OUTPUT CHARACTERISTICS
IEC TS 62903:2018 Ultrasonics - Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method
I.S. EN 60500:2017 UNDERWATER ACOUSTICS - HYDROPHONES - PROPERTIES OF HYDROPHONES IN THE FREQUENCY RANGE 1 HZ TO 500 KHZ
BS EN 61846:1999 Ultrasonics. Pressure pulse lithotripters. Characteristics of fields
BS EN 61847:1998 Ultrasonics. Surgical systems. Measurement and declaration of the basic output characteristics
CEI EN 61846 : 1999 ULTRASONICS - PRESSURE PULSE LITHOTRIPTERS - CHARACTERISTICS OF FIELDS
05/30141146 DC : DRAFT OCT 2005
CEI EN 61266 : 1998 ULTRASONICS - HAND-HELD PROBE DOPPLER FOETAL HEARTBEAT DETECTORS - PERFORMANCE REQUIREMENTS AND METHODS OF MEASUREMENT AND REPORTING
IEC 60565:2006 Underwater acoustics - Hydrophones - Calibration in the frequency range 0,01 Hz to 1 MHz
IEC 61846:1998 Ultrasonics - Pressure pulse lithotripters - Characteristics of fields
IEC 61266:1994 Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting
BS EN 60565:2007 Underwater acoustics. Hydrophones. Calibration in the frequency range 0,01 Hz to 1 MHz
BS EN 61101:1994 Specification for absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz
IEC 62092:2001 Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz
EN 60565:2007 Underwater acoustics - Hydrophones - Calibration in the frequency range 0,01 Hz to 1 MHz
EN 61266:1995 Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting
EN 61102:1993/A1:1994 MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ
EN 61101:1993 The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.