• Shopping Cart
    There are no items in your cart

IEC 60889:1987

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Hard-drawn aluminium wire for overhead line conductors

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

04-03-2022

Language(s)

English - French, English, French, Spanish, Castilian

Published date

30-11-1987

€20.79
Excluding VAT

FOREWORD
PREFACE
1 Scope
2 Values for hard-drawn aluminium wire
3 Material
4 Freedom from defects
5 Diameter and tolerance on diameter
6 Length and tolerance on length
7 Joints
8 Sampling
9 Place of testing
10 Mechanical tests
11 Resistivity tests
12 Certificate of compliance

Applies to hand-drawn aluminium wires for the manufacture of stranded conductors for overhead power transmission purposes. Specifies the mechanical and electrical properties of wires in the diameter rank 1.25 mm to 5.00 mm. This publication supersedes IEC 60111 (1983).

DevelopmentNote
Supersedes IEC 60111 (03/2001) Also numbered as BS EN 60889. (12/2005) Stability date: 2019. (09/2017)
DocumentType
Standard
Pages
9
PublisherName
International Electrotechnical Committee
Status
Superseded
Supersedes

Standards Relationship
NF EN 60889 : 1998 Identical
NFC 34 111 : 1993 Similar to
HD 532 : 200S1 Identical
NEN NPR 1019899 : 1989 Identical
NEN 10889 : 1997 Identical
I.S. EN 60889:1999 Identical
PN EN 60889 : 2002 Identical
SAC GB/T 17048 : 1997 Identical
SN EN 60889 : 1997 Identical
UNE-EN 60889:1997 Identical
CEI EN 60889 : 1997 Identical
EN 60889:1997 Identical
DIN EN 60889:1997-08 Identical
UNE 21014:1992 Identical
BS 7365:1990 Identical

I.S. EN 60794-4-10:2014 OPTICAL FIBRE CABLES - PART 4-10: FAMILY SPECIFICATION - OPTICAL GROUND WIRES (OPGW) ALONG ELECTRICAL POWER LINES
97/202499 DC : 0
02/205756 DC : DRAFT MAY 2002 IEC 60794-4. ED 2.0 - OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES
BS EN 62420:2008 Concentric lay stranded overhead electrical conductors containing one or more gap(s)
BS EN 60794-4-10:2014 Optical fibre cables Family specification. Optical ground wires (OPGW) along electrical power lines
PREN 50540 : DRAFT 2009 ALUMINIUM CONDUCTORS STEEL SUPPORTED (ACSS) FOR OVERHEAD LINES
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
CEI EN 62420 : 2009 CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S)
EN 60794-4:2003 Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines
EN 50540:2010 Conductors for overhead lines - Aluminium Conductors Steel Supported (ACSS)
BS EN 50540:2010 Conductors for overhead lines. Aluminium conductors steel supported (ACSS)
11/30215604 DC : 0 BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
CEI EN 62219 : 2002 OVERHEAD ELECTRICAL CONDUCTORS - FORMED WIRE, CONCENTRIC LAY, STRANDED CONDUCTORS
BS IEC 60287-1-1 : 2006 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL
I.S. EN 62420:2008 CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S)
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
IEC 60794-4:2003 Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
06/30156083 DC : DRAFT SEP 2006 BS EN 62420 - CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR GAP(S)
UNE-EN 50540:2010 Conductors for overhead lines - Aluminium Conductors Steel Supported (ACSS)
I.S. EN 60794-4:2003 OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES
CEI 20-21/1-1 : 2007 ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 1-1: CURRENT RATING EQUATIONS (100% LOAD FACTOR) AND CALCULATION OF LOSSES - GENERAL
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS 7769-1.1:1997 Electric cables. Calculation of the current rating. Current rating equations (100% load factor) and calculation of losses General
NF EN 62420 : 2011 CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S)
09/30208778 DC : 0 BS EN 50540 - ALUMINIUM CONDUCTORS STEEL SUPPORTED (ACSS) FOR OVERHEAD LINES
05/30131909 DC : DRAFT APR 2005
NF EN 62004 : 2009 THERMAL-RESISTANT ALUMINIUM ALLOY WIRE FOR OVERHEAD LINE CONDUCTOR
IEC 60287-1-1:2006+AMD1:2014 CSV Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General
IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC 60794-4-10:2014 Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrical power lines
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC 62420:2008 Concentric lay stranded overhead electrical conductors containing one or more gap(s)
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
EN 60794-4-10:2014 Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrical power lines
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
15/30320892 DC : 0 BS EN 60794-4 - OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
BS EN 62004:2009 Thermal-resistant aluminium alloy wire for overhead line conductor
CEI 301-1 : 1997 ELECTRIC DRIVES - DICTIONARY
I.S. EN 62004:2009 THERMAL RESISTANT ALUMINIUM ALLOY WIRE FOR OVERHEAD LINE CONDUCTOR
13/30292534 DC : 0 BS EN 60794-4-10 ED 2.0 - OPTICAL FIBRE CABLES - PART 4-10: FAMILY SPECIFICATION - OPGW (OPTICAL GROUND WIRES) ALONG ELECTRICAL POWER LINES
BS EN 62219:2002 Overhead electrical conductors. Formed wire, concentric lay, stranded conductors
I.S. EN 62219:2002 OVERHEAD ELECTRICAL CONDUCTORS - FORMED WIRE, CONCENTRIC LAY, STRANDED CONDUCTORS
BS EN 60794-4:2003 Optical fibre cables Sectional specification. Aerial optical cables along electrical power lines
NF EN 60794-4 : 2004 OPTICAL FIBER CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES
I.S. EN 50540:2010 CONDUCTORS FOR OVERHEAD LINES - ALUMINIUM CONDUCTORS STEEL SUPPORTED (ACSS)
UNE 21144-1-1:2012 Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General
IEC 62004:2007 Thermal-resistant aluminium alloy wire for overhead line conductor
ASTM B 889 : 1998 Standard Specification for Solid Hard-Drawn Aluminum Wire for Electrical Purposes (Withdrawn 2003)
IEC 62219:2002 Overhead electrical conductors - Formed wire, concentric lay, stranded conductors
EN 62004:2009 Thermal-resistant aluminium alloy wire for overhead line conductor
EN 62219:2002 Overhead electrical conductors - Formed wire, concentric lay, stranded conductors
EN 62420:2008 Concentric lay stranded overhead electrical conductors containing one or more gap(s)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.