IEC 61000-5-7:2001
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
12-01-2001
FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 General
4 Definitions
5 Shielding performance designations
6 General test approach
7 Testing requirements
7.1 Climatic conditions
7.2 Test samples
7.3 Analysis requirements
7.4 Test frequency selection
7.5 Test matrix definition
7.6 Test equipment requirements
7.7 Safety requirements
7.8 Test plan requirements
7.9 Test performance
7.10 Test conclusions
7.11 Test documentation
8 Classification
Annex A (informative) Some issues for selection of
enclosure electromagnetic protection requirements
Annex B (informative) Summary of responsibilities of
relevant end-product technical committees
Annex C (informative) Other test methods - TEM cells
and striplines
Annex D (informative) Antennas
Bibliography
Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.
Committee |
TC 77/SC 77C
|
DevelopmentNote |
Stability date: 2018. (11/2017)
|
DocumentType |
Standard
|
Pages |
51
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NEN EN IEC 61000-5-7 : 2001 | Identical |
I.S. EN 61000-5-7:2001 | Identical |
PN EN 61000-5-7 : 2005 | Identical |
SAC GB/T 30556-7 : 2014 | Identical |
SN EN 61000-5-7 : 2001 | Identical |
DIN EN 61000-5-7 : 2001 | Identical |
VDE 0847-5-7 : 2001 | Identical |
BS EN 61000-5-7:2001 | Identical |
CEI EN 61000-5-7 : 2003 | Identical |
EN 61000-5-7:2001 | Identical |
NF EN 61000-5-7 : 2001 | Identical |
UNE-EN 61000-5-7:2002 | Identical |
BS EN 61587-3:2013 | Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Electromagnetic shielding performance tests for cabinets and subracks |
09/30194273 DC : 0 | BS EN 62208 - EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS |
CEI EN 61587-3 : 2014 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS |
13/30286075 DC : 0 | BS EN 61000-4-36 ED 1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-36: TESTING AND MEASUREMENT TECHNIQUES - IEMI IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 62208:2011 | Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements |
PD IEC/TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI |
11/30254082 DC : 0 | BS EN 61587-3 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS |
BS EN 62208:2011 | Empty enclosures for low-voltage switchgear and controlgear assemblies. General requirements |
IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences |
CEI EN 62208 : 2012 | EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS |
IEC TS 61000-5-9:2009 | Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM |
IEEE 299.1-2013 | IEEE Standard Method for Measuring the Shielding Effectiveness of Enclosures and Boxes Having all Dimensions between 0.1 m and 2 m |
DD IEC/TS 61000-5-9:2009 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM |
UNE-EN 62208:2012 | Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements |
I.S. EN 61000-4-21:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-21: TESTING AND MEASUREMENT TECHNIQUES - REVERBERATION CHAMBER TEST METHODS |
BS EN 61000-4-21:2011 | Electromagnetic compatibility (EMC) Testing and measurement techniques. Reverberation chamber test methods |
I.S. EN 62208:2011 | EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS (IEC 62208:2011) |
IEC TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI |
IEC 61587-3:2013 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks |
IEC 62208:2011 | Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements |
PD IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC). Installation and mitigation guidelines Mitigation of external EM influences |
92/03769 DC : DRAFT NOV 1992 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5: INSTALLATION AND MITIGATION GUIDELINES - SECTION 3: CABLING AND WIRING |
I.S. EN 61587-3:2013 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS (IEC 61587-3:2013 (EQV)) |
IEC 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
EN 61587-3:2013 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks |
EN 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 61000-4-23:2016 | Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.