• EN 62208:2011

    Current The latest, up-to-date edition.

    EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS (IEC 62208:2011)

    Available format(s): 

    Language(s): 

    Published date:  28-10-2011

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Classification
    5 EMC requirements
    6 Information to be given regarding the enclosure
    7 Service conditions
    8 Design and construction
    9 Type tests
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Pertains to empty enclosures, prior to the incorporation of switchgear and controlgear components by the user, as supplied by the enclosure manufacturer.

    General Product Information - (Show below) - (Hide below)

    Committee SR 121B
    Development Note Supersedes EN 50298 (01/2004)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 61439-1:2011 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011)
    S.R. HD 60364-5-53:2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    I.S. EN 61439-1:2011 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011)
    UNE-EN 61439-1:2012 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    UNE-HD 60364-5-53:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear
    HD 60364-5-53:2015/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 61000-5-7 : 2001 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5-7: INSTALLATION AND MITIGATION GUIDELINES - DEGREES OF PROTECTION BY ENCLOSURES AGAINST ELECTROMAGNETIC DISTURBANCES (EM CODE)
    EN 62262:2002 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES FOR ELECTRICAL EQUIPMENT AGAINST EXTERNAL MECHANICAL IMPACTS (IK CODE)
    EN 60085:2008 ELECTRICAL INSULATION - THERMAL EVALUATION AND DESIGNATION
    EN 60068-2-2:2007 ENVIRONMENTAL TESTING - PART 2-2: TESTS - TEST B: DRY HEAT
    EN 61439-1:2011 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (IEC 61439-1:2011)
    ISO 11469:2016 Plastics Generic identification and marking of plastics products
    IEC 60068-2-11:1981 ENVIRONMENTAL TESTING - TEST KA: SALT MIST
    EN ISO 2409:2013 PAINTS AND VARNISHES - CROSS-CUT TEST (ISO 2409:2013)
    EN ISO 178:2010/A1:2013 PLASTICS - DETERMINATION OF FLEXURAL PROPERTIES (ISO 178:2010/AMD 1:2013)
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    EN ISO 11469:2016 PLASTICS - GENERIC IDENTIFICATION AND MARKING OF PLASTICS PRODUCTS (ISO 11469:2016)
    IEC 60085:2007 ELECTRICAL INSULATION - THERMAL EVALUATION AND DESIGNATION
    ISO 4628-3:2016 Paints and varnishes Evaluation of degradation of coatings Designation of quantity and size of defects, and of intensity of uniform changes in appearance Part 3: Assessment of degree of rusting
    EN ISO 4628-3:2016 PAINTS AND VARNISHES - EVALUATION OF DEGRADATION OF COATINGS - DESIGNATION OF QUANTITY AND SIZE OF DEFECTS, AND OF INTENSITY OF UNIFORM CHANGES IN APPEARANCE - PART 3: ASSESSMENT OF DEGREE OF RUSTING (ISO 4628-3:2016)
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 60695-2-10:2013 FIRE HAZARD TESTING - PART 2-10: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE APPARATUS AND COMMON TEST PROCEDURE (IEC 60695-2-10:2013)
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
    CLC/TR 60890:2002 A METHOD OF TEMPERATURE-RISE ASSESSMENT BY EXTRAPOLATION FOR PARTIALLY TYPE-TESTED ASSEMBLIES (PTTA) OF LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR
    ISO 4892-2:2013 Plastics Methods of exposure to laboratory light sources Part 2: Xenon-arc lamps
    IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    EN 60068-2-11 : 1999 ENVIRONMENTAL TESTING - TESTS - TEST KA-SALT MIST
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN 60068-2-30:2005 ENVIRONMENTAL TESTING - PART 2-30: TESTS - TEST DB: DAMP HEAT, CYCLIC (12 H + 12 H CYCLE)
    ISO 2409:2013 Paints and varnishes Cross-cut test
    IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
    ISO 178:2010 Plastics Determination of flexural properties
    EN ISO 4892-2:2013 PLASTICS - METHODS OF EXPOSURE TO LABORATORY LIGHT SOURCES - PART 2: XENON-ARC LAMPS (ISO 4892-2:2013)
    IEC 61000-5-7:2001 Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code)
    IEC TR 60890:2014 A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation
    EN 60695-2-11:2014 FIRE HAZARD TESTING - PART 2-11: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY TEST METHOD FOR END-PRODUCTS (GWEPT) (IEC 60695-2-11:2014)
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective