IEC 61243-3:2014
Current
The latest, up-to-date edition.
Live working - Voltage detectors - Part 3: Two-pole low-voltage type
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
09-10-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Tests
6 Conformity testing
7 Modifications
Annex A (informative) - Differences with
IEC 61010 series
Annex B (normative) - Supplementary functions: Phase
indication - Rotating field indication -
Continuity check
Annex C (normative) - Instructions for use
Annex D (normative) - General type test procedure
Annex E (normative) - Classification of defects and
associated requirements and tests
Annex F (informative) - In-service care and use
Annex G (informative) - Voltage detectors and the presence
of interference voltages
Bibliography
IEC 61243-3:2014 is applicable to hand-held two-pole voltage detectors with their accessories (crocodile clips and detachable leads) to be used in contact with parts of electrical systems for a.c. voltages not exceeding 1 000 V at nominal frequencies between 16 2/3 Hz and up to 500 Hz, and/or for d.c. voltages not exceeding 1 500 V. Contact electrode extensions are not covered by this standard. Voltage detectors covered by this standard are intended to be used under dry and humid conditions, both indoor and outdoor. They are not intended to be used under rain conditions. Voltage detectors covered by this standard are not intended to be used for continuous operation. Voltage detectors covered by this standard are intended to be used up to 2 000 m above sea level. This standard also includes provisions for the following supplementary functions when available:
- phase indication;
- rotating field indication;
- and continuity check. Other supplementary functions are not covered by this standard. Voltage detectors covered by this standard are not considered as measuring devices. Relevant safety requirements for measuring devices are included in IEC 61010 series. This third edition cancels and replaces the second edition published in 2009. It is a technical revision which includes the following significant technical changes with respect to the previous edition:
- requirement and test to manage interference voltages at power frequencies;
- and informative annex on voltage detectors and the presence of interference voltages.
The contents of the corrigendum of January 2015 and May 2015 have been included in this copy.
Committee |
TC 78
|
DevelopmentNote |
Stability date: 2020. (10/2014) COR 2 applies to the French text only. (05/2015)
|
DocumentType |
Standard
|
Pages |
152
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
OVE/ONORM EN 61243-3 : 2015 | Identical |
NF EN 61243-3 : 2015 | Identical |
GOST IEC 61243-3 : 2014 | Identical |
NBN EN 61243-3 : 2015 COR 2 2015 | Identical |
NEN EN IEC 61243-3 : 2014 C1 2015 | Identical |
PN EN 61243-3 : 2015 AC 1 2015 | Identical |
EN 61243-3:2014 | Identical |
NEN-EN-IEC 61243-3:2014 | Identical |
PN-EN 61243-3:2015-04 | Identical |
UNE-EN 61243-3:2015 | Identical |
BS EN 61243-3:2014 | Identical |
CEI EN 61243-3 : 2015 | Identical |
EN 61243-3:2014/AC:2015 | Identical |
IS 16619 : Part 3 : 2021 | Identical |
VDE 0682-401 : 2015 | Identical |
SN EN 61243-3:2014 | Identical |
DIN EN 61243-3 : 2015 | Identical |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 :2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
15/30320941 DC : 0 | PD IEC/TR 61243-6 ED1.0 LIVE WORKING - VOLTAGE DETECTORS - PART 6: GUIDELINES ON NON-CONTACT VOLTAGE DETECTORS (NCVD) FOR USE AT NOMINAL VOLTAGES ABOVE 1 KV A.C. |
IEC TR 61243-6:2017 | Live working - Voltage detectors - Part 6: Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 : 2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
08/30191891 DC : DRAFT OCT 2008 | BS EN 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CAN/CSA-C22.2 NO. 61010-1-12 (R2017) | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (Tri-national standard, with UL 61010-1 and ANSI/ISA-61010-1 (82.02.01) |
UNE-EN 61010-1:2011 | Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 1: General requirements |
ISA 61010-1 : 2008 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 61010-1:2010 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
PD IEC/TS 62850:2013 | Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements for equipment intended to be used in educational establishments by children |
IEC TS 62850:2013 | Safety requirements for electrical equipment for measurement, control, and laboratory use - General requirements for equipment intended to be used in educational establishments by children |
PD IEC/TR 61243-6:2017 | Live working. Voltage detectors Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC |
CSA C22.2 No. 61010.1 : 2012 : FR | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61010.1 :2012 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
I.S. EN 61010-1:2010/A1:2019 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 :2016 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 : 2016 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
I.S. HD 637:1999 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 61477:2009 | Live working - Minimum requirements for the utilization of tools, devices and equipment |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
ISO 354:2003 | Acoustics — Measurement of sound absorption in a reverberation room |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60743:2013 | Live working - Terminology for tools, devices and equipment |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60721-2-1:2013 | Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity |
IEC 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 286-1:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 1: Basis of tolerances, deviations and fits |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 61318:2007 | Live working - Conformity assessment applicable to tools, devices and equipment |
ISO 286-2:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 61010-031:2015 RLV | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test |
IEC 60050-651:2014 | International Electrotechnical Vocabulary (IEV) - Part 651: Live working |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 61557-7:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 3745:2012 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.