IEC 61745:2017
Current
The latest, up-to-date edition.
End-face image analysis procedure for the calibration of optical fibre geometry test sets
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
28-07-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General information and preparation for calibration
5 Calibration
6 Evaluation of uncertainties
7 Documentation
Annex A (normative) - Mathematical basis for
measurement uncertainty calculations
Annex B (informative) - Derivation of calibration
factors
Annex C (informative) - Examples for the determination
of calibration factors
Annex D (informative) - Calculation of uncertainties
Annex E (informative) - Worked examples for the
determination of uncertainties
Annex F (informative) - Generation of working standards
Annex G (informative) - Estimation of uncertainty in the
measurement of core/cladding concentricity error
Annex H (informative) - Estimation of uncertainty in the
measurement of non-circularity
Bibliography
IEC 61745:2017 describes the calibration of test sets that perform end-face image analysis, also known as "near-field" or "grey-scale" analysis. The principles, however, can be applied to test sets of a different type. The procedures outlined are performed by calibration laboratories and by the manufacturers or users of geometry test sets, for the purpose of calibrating geometry test sets and for evaluating the uncertainties in measurements made on calibrated test sets. The calibration of fibre coating or cable measurement test sets is not covered by this document. This second edition cancels and replaces the first edition, published in 1998, and constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:
a) removal of the limitation of single mode optical fibre geometry test sets to include multimode;
b) addition of a new annex as mathematical basis.
Keywords: end-face image analysis, optical fibre geometry test sets
Committee |
TC 86
|
DevelopmentNote |
Stability Date: 2024. (08/2017)
|
DocumentType |
Standard
|
Pages |
81
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS EN 61745:2017 | Identical |
EN 61745:2017 | Identical |
NEN EN IEC 61745 : 2017 | Identical |
JIS C 6828:2019 | Identical |
UNE-EN 61745:2017 | Identical |
CEI EN 61745:2018 | Identical |
NEN IEC 61745 : 1999 | Identical |
NF EN 61745 : 2018 | Identical |
BIS IS 16285 : 2014 | Identical |
PN EN 61745 : 2018 | Identical |
BS IEC 61745:1998 | Identical |
PNE-prEN 61745:2017 | Identical |
BS EN 61280-1-4:2010 | Fibre optic communication subsystem test procedures General communication subsystems. Light source encircled flux measurement method |
CSA ISO/IEC 14763-3 : 2015 | INFORMATION TECHNOLOGY - IMPLEMENTATION AND OPERATION OF CUSTOMER PREMISES CABLING - PART 3: TESTING OF OPTICAL FIBRE CABLING |
08/30179858 DC : DRAFT MAR 2008 | BS EN 61280-1-4 - FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 1-4: GENERAL COMMUNICATION SUBSYSTEMS - LIGHT SOURCE ENCIRCLED FLUX MEASUREMENT METHOD |
09/30203828 DC : 0 | BS EN 62614 - LAUNCH CONDITION REQUIREMENTS FOR MEASURING MULTIMODE ATTENUATION |
CEI EN 62496-2 : 1ED 2017 | OPTICAL CIRCUIT BOARDS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2: GENERAL GUIDANCE FOR DEFINITION OF MEASUREMENT CONDITIONS FOR OPTICAL CHARACTERISTICS OF OPTICAL CIRCUIT BOARDS |
IEC 62496-2:2017 | Optical circuit boards - Basic test and measurement procedures - Part 2: General guidance for definition of measurement conditions for optical characteristics of optical circuit boards |
I.S. EN 61280-4-2:2014 | FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLE-MODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
CEI EN 62614 : 2012 | FIBRE OPTICS - LAUNCH CONDITION REQUIREMENTS FOR MEASURING MULTIMODE ATTENUATION |
EN 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
EN 61280-4-1:2009 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
EN 61280-1-4:2010 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
BS EN 60793-1-20:2014 | Optical fibres Measurement methods and test procedures. Fibre geometry |
IEC TR 61282-11:2012 | Fibre optic communication system design guides - Part 11: Multimode launch conditions |
I.S. EN 61300-3-53:2015 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-53: EXAMINATIONS AND MEASUREMENTS - ENCIRCLED ANGULAR FLUX (EAF) MEASUREMENT METHOD BASED ON TWO-DIMENSIONAL FAR FIELD DATA FROM STEP INDEX MULTIMODE WAVEGUIDE (INCLUDING FIBRE) |
BS ISO/IEC 14763-3 : 2006 | INFORMATION TECHNOLOGY - IMPLEMENTATION AND OPERATION OF CUSTOMER PREMISES CABLING - PART 3: TESTING OF OPTICAL FIBRE CABLING |
ISO/IEC 14763-3:2014 | Information technology — Implementation and operation of customer premises cabling — Part 3: Testing of optical fibre cabling |
IEC TR 62614-2:2015 | Fibre optics - Multimode launch conditions - Part 2: Determination of launch condition requirements for measuring multimode attenuation |
IEC 61280-4-1:2009 | Fibre-optic communication subsystem test procedures - Part 4-1: Installed cable plant - Multimode attenuation measurement |
EN 61300-3-53:2015 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-53: Examinations and measurements - Encircled angular flux (EAF) measurement method based on two-dimensional far field data from step index multimode waveguide (including fibre) |
BS EN 61280-4-2:2014 | Fibre-optic communication subsystem test procedures Installed cable plant. Single-mode attenuation and optical return loss measurement |
I.S. EN 62614:2010 | FIBRE OPTICS - LAUNCH CONDITION REQUIREMENTS FOR MEASURING MULTIMODE ATTENUATION |
CEI EN 61280-4-1 : 2011 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
13/30279646 DC : 0 | BS EN 61300-3-53 - FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-53: EXAMINATIONS AND MEASUREMENTS - ENCIRCLED ANGULAR FLUX (EAF) MEASUREMENT METHOD BASED ON TWO-DIMENSIONAL FAR FIELD DATA FROM MULTIMODE FIBRE |
13/30286622 DC : 0 | BS EN 60793-1-20 - OPTICAL FIBRES - PART 1-20: MEASUREMENT METHODS AND TEST PROCEDURES - FIBRE GEOMETRY |
I.S. EN 61280-1-4:2010 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 1-4: GENERAL COMMUNICATION SUBSYSTEMS - LIGHT SOURCE ENCIRCLED FLUX MEASUREMENT METHOD |
12/30266214 DC : 0 | ISO/IEC CD 14763-3 - IMPLEMENTATION AND OPERATION OF CPC - PART 3: TESTING OF OPTICAL FIBRE CABLING (2ND EDITION) |
CEI EN 61280-4-2 : 2015 | FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLE-MODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
IEC PAS 62614:2009 | Fibre optics - Launch condition requirements for measuring multimode attenuation |
I.S. EN 62496-2:2017 | OPTICAL CIRCUIT BOARDS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2: GENERAL GUIDANCE FOR DEFINITION OF MEASUREMENT CONDITIONS FOR OPTICAL CHARACTERISTICS OF OPTICAL CIRCUIT BOARDS |
CEI EN 61280-1-4 : 2011 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 1-4: GENERAL COMMUNICATION SUBSYSTEMS - LIGHT SOURCE ENCIRCLED FLUX MEASUREMENT METHOD |
10/30240050 DC : DRAFT DEC 2010 | BS EN 61280-4-2 - FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-2: INSTALLED CABLE PLANT - SINGLEMODE ATTENUATION AND OPTICAL RETURN LOSS MEASUREMENT |
17/30331301 DC : 0 | BS ISO/IEC 14763-3 AMENDMENT 1 - INFORMATION TECHNOLOGY - IMPLEMENTATION AND OPERATION OF CUSTOMER PREMISES CABLING - PART 3: TESTING OF OPTICAL FIBRE CABLING |
BS EN 61300-3-53:2015 | Fibre optic interconnecting devices and passive components. Basic test and measurement procedures Examinations and measurements. Encircled angular flux (EAF) measurement method based on two-dimensional far field data from step index multimode waveguide (including fibre) |
BS EN 61280-4-1:2009 | Fibre optic communication subsystem test procedures Installed cable plant. Multimode attenuation measurement |
CEI EN 61746-2 : 2012 | CALIBRATION OF OPTICAL TIME-DOMAIN REFLECTOMETERS (OTDR) - PART 2: OTDR FOR MULTIMODE FIBRES |
PD IEC/TR 61282-11:2012 | Fibre optic communication system design guides Multimode launch conditions |
15/30326655 DC : 0 | BS EN 61280-4-1 - FIBRE-OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
BS EN 62496-2:2017 | Optical circuit boards. Basic test and measurement procedures General guidance for definition of measurement conditions for optical characteristics of optical circuit boards |
BS EN 62614:2010 | Fibre optics. Launch condition requirements for measuring multimode attenuation |
I.S. EN 61280-4-1:2009 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
IEC 61280-1-4:2009 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
I.S. EN 61746-2:2011 | CALIBRATION OF OPTICAL TIME-DOMAIN REFLECTOMETERS (OTDR) - PART 2: OTDR FOR MULTIMODE FIBRES |
I.S. EN 60793-1-20:2014 | OPTICAL FIBRES - PART 1-20: MEASUREMENT METHODS AND TEST PROCEDURES - FIBRE GEOMETRY |
EN 61746-2:2011/AC:2014 | CALIBRATION OF OPTICAL TIME-DOMAIN REFLECTOMETERS (OTDR) - PART 2: OTDR FOR MULTIMODE FIBRES |
IEC 62614:2010 | Fibre optics - Launch condition requirements for measuring multimode attenuation |
UNE-EN 60793-1-20:2015 | Optical fibres - Part 1-20: Measurement methods and test procedures - Fibre geometry |
IEC 60793-1-20:2014 | Optical fibres - Part 1-20: Measurement methods and test procedures - Fibre geometry |
IEC 61280-4-2:2014 | Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode attenuation and optical return loss measurement |
BS EN 61746-2:2011 | Calibration of optical time-domain reflectometers (OTDR) OTDR for multimode fibres |
17/30315248 DC : 0 | BS EN 62496-2 ED 1.0 - OPTICAL CIRCUIT BOARDS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2: GENERAL GUIDANCE FOR DEFINITION OF MEASUREMENT CONDITIONS FOR OPTICAL CHARACTERISTICS OF OPTICAL CIRCUIT BOARDS |
EN 62496-2:2017 | Optical circuit boards - Basic test and measurement procedures - Part 2: General guidance for definition of measurement conditions for optical characteristics of optical circuit boards |
IEC 61746-2:2010 | Calibration of optical time-domain reflectometers (OTDR) - Part 2: OTDR for multimode fibres |
EN 60793-1-20:2014/AC:2016-03 | OPTICAL FIBRES - PART 1-20: MEASUREMENT METHODS AND TEST PROCEDURES - FIBRE GEOMETRY (IEC 60793-1-20:2014/COR1:2016) |
NF EN 61280-4-1 : 2010 | FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES - PART 4-1: INSTALLED CABLE PLANT - MULTIMODE ATTENUATION MEASUREMENT |
EN 62614 : 2010 | FIBRE OPTICS - LAUNCH CONDITION REQUIREMENTS FOR MEASURING MULTIMODE ATTENUATION |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.