IEC 62153-4-3:2013
Current
The latest, up-to-date edition.
Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
22-10-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Test methods
6 Test method A: Matched inner circuit
with damping resistor in outer circuit
7 Test method B: Inner circuit with load
resistor and outer circuit without damping
resistor
8 Test method C: (Mismatched)-Short-Short
without damping resistor
Annex A (normative) - Determination of the impedance
of the inner circuit
Annex B (normative) - Impedance matching adapter
Annex C (normative) - Sample preparation for 'milked
on braid' method
Annex D (informative) - Triaxial test set-up depicted
as a T-circuit
Annex E (informative) - Cut-off frequency of the triaxial
set-up for the measurement of the transfer
impedance
Annex F (informative) - Impact of ground loops on low
frequency measurements
Bibliography
IEC 62153-4-3:2013(E) determines the screening effectiveness of a cable shield by applying a well-defined current and voltage to the screen of the cable and measuring the induced voltage in order to determine the surface transfer impedance. This test measures only the magnetic component of the transfer impedance. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- now three different test configurations are described;
- formulas to calculate the maximum frequency up to which the different test configurations can be used are included;
- the effect of ground loops is described.
Committee |
TC 46
|
DevelopmentNote |
Stability date: 2020. (11/2017)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN IEC 62153-4-3 : 2013 | Identical |
BS IEC 62153-4-3:2013 | Identical |
DS IEC 62153-4-3 : 2013 | Identical |
NF EN 62153-4-3 : 2005 PR | Identical |
15/30332390 DC : 0 | BS EN 50117-10-1 - COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
UNE-EN 61400-24:2011 | Wind turbines - Part 24: Lightning protection |
15/30332399 DC : 0 | BS EN 50117-11-2 - COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ |
BS EN 4674-001:2017 | Aerospace series. Electrical cables, installation. Self-wrapping shielding (EMI) protective sleeve Technical specification |
17/30348799 DC : 0 | BS EN 62153-4-8 - METALLIC CABLES AND OTHER PASSIVE COMPONENTS TEST METHODS - PART 4-8: ELECTROMAGNETIC COMPATIBILITY (EMC) - CAPACITIVE COUPLING ADMITTANCE |
I.S. EN 61726:2015 | CABLE ASSEMBLIES, CABLES, CONNECTORS AND PASSIVE MICROWAVE COMPONENTS - SCREENING ATTENUATION MEASUREMENT BY THE REVERBERATION CHAMBER METHOD |
12/30263095 DC : 0 | BS EN 60966-2-7 ED.1 - RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-7: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-47 CONNECTORS |
BS EN 6049-008:2017 | Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Self-wrapping shielded (EMI) protective sleeve with nickel copper braid, flexible post installation operating temperature from -55 °C to 200 °C. Product standard |
IEC 62153-4-16:2016 | Metallic communication cable test methods - Part 4-16: Electromagnetic compatibility (EMC) - Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up |
IEC 62153-4-9:2018 RLV | Metallic communication cable test methods - Part 4 - 9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method |
IEC 62153-4-6:2017 RLV | Metallic cables and other passive components test methods - Part 4-6: Electromagnetic compatibility (EMC) - Surface transfer impedance - Line injection method |
BS IEC 61196-9:2014 | Coaxial communication cables Sectional specification for RF flexible cables |
BS EN 4674-003:2017 | Aerospace series. Electrical cables, installation. Self-wrapping shielding (EMI) protective sleeve Open sleeve. Inside pressurized area. EMI protection 5 kA. Temperature range - 65 °C to 200 °C. Product standard |
15/30334758 DC : 0 | BS IEC 62153-4-16 ED 1.0 - I METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-16: EXTENSION OF THE FREQUENCY RANGE TO HIGHER FREQUENCIES FOR TRANSFER IMPEDANCE AND TO LOWER FREQUENCIES FOR SCREENING ATTENUATION MEASUREMENTS USING THE TRIAXIAL SET-UP |
ISO 14572:2011 | Road vehicles — Round, sheathed, 60 V and 600 V screened and unscreened single- or multi-core cables — Test methods and requirements for basic- and high-performance cables |
17/30348794 DC : 0 | BS EN 62153-4-7+A1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE ZT AND SCREENING ATTENUATION AS OR COUPLING ATTENUATION AC OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD |
07/30152672 DC : 0 | BS EN 60966-2-5 - RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 TO 1000 MHZ, IEC 61169-2 CONNECTORS |
BS ISO 14572:2011 | Road vehicles. Round, sheathed, 60 V and 600 V screened and unscreened single- or multi-core cables. Test methods and requirements for basic- and high-performance cables |
10/30196613 DC : 0 | BS ISO 14572 - ROAD VEHICLES - ROUND, SHEATHED, 60 V AND 600 V SCREENED AND UNSCREENED SINGLE- OR MULTI-CORE CABLES - TEST METHODS AND REQUIREMENTS FOR BASIC AND HIGH-PERFORMANCE CABLES |
15/30332369 DC : 0 | BS EN 50117-9-1 - COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
I.S. EN 4674-001:2017 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION |
IEC 61196-9:2014 | Coaxial communication cables - Part 9: Sectional specification for RF flexible cables |
EN 4674-004:2017 | Aerospace series - Electrical cables, installation - Self-wrapping shielding (EMI) protective sleeve - Part 004: Open sleeve - Outside pressurized area - EMI protection 10 kA - Temperature range - 65 °C to 200 °C - Product standard |
BIS IS/IEC 61400-24 : 2010 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
IEC 61196-7:2011 | Coaxial communication cables - Part 7: Sectional specification for cables for BCT cabling in accordance with ISO/IEC 15018 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz |
IEC 61726:2015 | Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method |
15/30332393 DC : 0 | BS EN 50117-10-2 - COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
PD IEC/TR 62153-4-1:2010 | Metallic communication cable test methods Electromagnetic compatibility (EMC). Introduction to electromagnetic (EMC) screening measurements |
15/30322162 DC : 0 | BS EN 4674-003 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
17/30354707 DC : 0 | BS ISO 19642-2 - ROAD VEHICLES - AUTOMOTIVE CABLES - PART 2: TEST METHODS |
15/30332386 DC : 0 | BS EN 50117-9-3 - COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ |
13/30279876 DC : 0 | BS EN 62153-4-15 ED.1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-15: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING TRANSFER IMPEDANCE AND SCREENING ATTENUATION - OR COUPLING ATTENUATION WITH TRIAXIAL CELL |
I.S. EN 4674-004:2017 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 004: OPEN SLEEVE - OUTSIDE PRESSURIZED AREA - EMI PROTECTION 10 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
PREN 4674-001 : DRAFT 2015 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION |
PREN 4674-004 : 200P1 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 004: OPEN SLEEVE - OUTSIDE PRESSURIZED AREA - EMI PROTECTION 10 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
PREN 50117-11-2 : DRAFT 2015 | COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ |
IEC TS 62153-4-1:2014 | Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements |
I.S. EN 62153-4-7:2016 | METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD |
IEC 62153-4-15:2015 | Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell |
EN 62153-4-7:2016/AC:2016-05 | METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD (IEC 62153-4-7:2015/COR1:2016) |
CEI EN 61400-24 : 2011 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
14/30314814 DC : 0 | BS EN 4674-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION |
PREN 50117-10-1 : DRAFT 2015 | COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
15/30332396 DC : 0 | BS EN 50117-11-1 - COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
PREN 50117-10-2 : DRAFT 2015 | COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
13/30283920 DC : 0 | BS EN 62153-4-7 ED.2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE TRANSFER IMPEDANCE Z[T] AND THE SCREENING ATTENUATION A[S] OR THE COUPLING ATTENUATION A[C] OF RF-CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ; TUBE |
IEC 62153-4-5:2006 | Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method |
PREN 50117-9-3 : DRAFT 2015 | COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ |
07/30152678 DC : 0 | BS EN 60966-2-6 - RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 TO 3000 MHZ, IEC 61169-24 CONNECTORS |
BS IEC 62153-4-15:2015 | Metallic Communication Cable test methods Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell |
06/30160408 DC : 0 | BS EN 60966-2-4 - RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 TO 3000 MHZ, IEC 61169-2 CONNECTORS |
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors |
BS EN 61726:2000 | Cable assemblies, cables, connectors and passive microwave components. Screening attenuation measurement by the reverberation chamber method |
PREN 4674-003 : 200P2 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
I.S. EN 61400-24:2010 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
EN 6049-008:2017 | Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 008: Self-wrapping shielded (EMI) protective sleeve with nickel copper braid, flexible post installation operating temperature from -55 °C to 200 °C - Product standard |
IEC 62153-4-9:2008 | Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method |
IEC 61196-11:2016 | Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene (PE) dielectric |
IEC TR 62153-4-1:2010 | Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic (EMC) screening measurements |
EN 4674-003:2017 | Aerospace series - Electrical cables, installation - Self-wrapping shielding (EMI) protective sleeve - Part 003: Open sleeve - Inside pressurized area - EMI protection 5 kA - Temperature range - 65 °C to 200 °C - Product standard |
EN 4674-001:2017 | Aerospace series - Electrical cables, installation - Self-wrapping shielding (EMI) protective sleeve - Part 001: Technical specification |
BS IEC 62153-4-6:2017 | Metallic cables and other passive components test methods Electromagnetic compatibility (EMC). Surface transfer impedance. Line injection method |
15/30331400 DC : 0 | BS EN 4674-004 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 004: OPEN SLEEVE - OUTSIDE PRESSURIZED AREA - EMI PROTECTION 10 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
BS EN 62153-4-7 : 2016 | METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD |
BS IEC 62153-4-16:2016 | Metallic communication cable test methods Electromagnetic compatibility (EMC). Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up |
PREN 50117-11-1 : DRAFT 2015 | COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
PREN 50117-9-1 : DRAFT 2015 | COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
15/30332377 DC : 0 | BS EN 50117-9-2 - COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
IEC 61196-5-1:2012 | Coaxial communication cables - Part 5-1: Blank detail specification for CATV trunk and distribution cables |
I.S. EN 4674-003:2017 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
09/30190333 DC : 0 | BS EN 61400-24 - WIND TURBINES - PART 24: LIGHTNING PROTECTION |
BS EN 61400-24:2010 | Wind turbines Lightning protection |
IEC 61196-5:2018 | Coaxial communication cables - Part 5: Sectional specification for CATV trunk and distribution cables |
PREN 50117-9-2 : DRAFT 2015 | COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
PREN 6049-008 : 200P3 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 008: SELF-WRAPPING SHIELDED (EMI) PROTECTIVE SLEEVE WITH NICKEL COPPER BRAID, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
I.S. EN 6049-008:2017 | AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTIVE SLEEVES IN META-ARAMID FIBRES - PART 008: SELF-WRAPPING SHIELDED (EMI) PROTECTIVE SLEEVE WITH NICKEL COPPER BRAID, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD |
UNE-EN 61726:2016 | Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method |
IEC 62153-4-6:2017 | Metallic cables and other passive components test methods - Part 4-6: Electromagnetic compatibility (EMC) - Surface transfer impedance - Line injection method |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEC 62153-4-7:2015 | Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method |
IEC 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
EN 61726:2015 | Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method |
EN 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
CSA IEC 61400-24 : 2012 : R2017 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
CSA IEC 61400-24:2012 | WIND TURBINES - PART 24: LIGHTNING PROTECTION |
IEC 62153-4-8:2006 | Metallic communication cable test methods - Part 4-8: Electromagnetic compatibility (EMC) - Capacitive coupling admittance |
IEC TR 62153-4-1:2010 | Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic (EMC) screening measurements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.