Connectors for electrical and electronic equipment - Product requirements - Part 3-126: Rectangular connectors - Detail specification for 5 pole power connector for industrial environments with push-pull locking
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-01-2023
English
09-01-2018
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Technical information
5 Dimensional information
6 Characteristics
7 Test schedule
IEC/PAS 61076-3-126:2018(E) covers rectangular IP65/IP67 connectors with 5 poles for electric power supply up to 16 A. These connectors consist of fixed and free connectors, either rewirable or non- rewirable (for both portions). It uses the general function principles of the push-pull connector housing system described in IEC 61076-3-117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications.
Male connectors have 5 square 1 mm electric contacts, with 16 A rated current. Connectors according this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer.
DevelopmentNote |
Stability Date: 2020. (01/2018)
|
DocumentType |
Miscellaneous Product
|
Pages |
42
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
BS EN IEC 61076-3-126:2023 | Identical |
IEC GUIDE 109:2012 | Environmental aspects - Inclusion in electrotechnical product standards |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60512-11-9:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat |
IEC 60512-11-10:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-10: Climatic tests - Test 11j: Cold |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 61076-3:2008 | Connectors for electronic equipment - Product requirements - Part 3: Rectangular connectors - Sectional specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60512-9-2:2011 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
IEC 60512-13-5:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-5: Mechanical operation tests - Test 13e: Polarizing and keying method |
IEC 60512-8-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 8-1: Static load tests (fixed connectors) - Test 8a: Static load, transverse |
IEC 60512-6-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-3: Dynamic stress tests - Test 6c: Shock |
IEC 60512-15-1:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-1: Connector tests (mechanical) - Test 15a: Contact retention in insert |
IEC 60512-8-2:2011 | Connectors for electronic equipment - Tests and measurements - Part 8-2: Static load tests (fixed connectors) - Test 8b: Static load, axial |
ISO 11469:2016 | Plastics — Generic identification and marking of plastics products |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 60512-6-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-1: Dynamic stress tests - Test 6a: Acceleration, steady state |
IEC 60512-13-2:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-2: Mechanical operation tests - Test 13b: Insertion and withdrawal forces |
IEC 62430:2009 | Environmentally conscious design for electrical and electronic products |
IEC 60512-2-5:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resistance tests - Test 2e: Contact disturbance |
IEC 60512-6-5:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 6: Dynamic stress tests - Section 5: Test 6e: Random vibration |
IEC 60512-14-7:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 14: Sealing tests - Section 7: Test 14g: Impacting water |
IEC 60512-16-5:2008 | Connectors for electronic equipment - Tests and measurements - Part 16-5: Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient contacts) |
IEC 60512-12-5:2006 | Connectors for electronic equipment - Tests and measurements - Part 12-5: Soldering tests - Test 12e: Resistance to soldering heat, soldering iron method |
IEC 60512-2-6:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-6: Electrical continuity and contact resistance tests - Test 2f: Housing (shell) electrical continuity |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60352-1:1997 | Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance |
IEC 60512-2-2:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-2: Electrical continuity and contact resistance tests - Test 2b: Contact resistance - Specified test current method |
IEC 60512-6-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-2: Dynamic stress tests - Test 6b: Bump |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60512-11-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-3: Climatic tests - Test 11c: Damp heat, steady state |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60352-8:2011 | Solderless connections - Part 8: Compression mount connections - General requirements, test methods and practical guidance |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
ISO 128-30:2001 | Technical drawings General principles of presentation Part 30: Basic conventions for views |
IEC 60512-11-1:1995 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 11: Climatic tests - Section 1: Test 11a - Climatic sequence |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60512-5-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-2: Current-carrying capacity tests - Test 5b: Current-temperature derating |
IEC 60512-19-3:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 19: Chemical resistance tests - Section 3: Test 19c - Fluid resistance |
IEC 60512-11-13:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-13: Climatic tests - Test 11n: Gas tightness, solderless wrapped connections |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
IEC 60512-17-3:2010 | Connectors for electronic equipment - Tests and measurements - Part 17-3: Cable clamping tests - Test 17c: Cable clamp resistance to cable pull (tensile) |
IEC 60512-17-4:2010 | Connectors for electronic equipment - Tests and measurements - Part 17-4: Cable clamping tests - Test 17d: Cable clamp resistance to cable torsion |
IEC 60512-12-4:2006 | Connectors for electronic equipment - Tests and measurements - Part 12-4: Soldering tests - Test 12d: Resistance to soldering heat, solder bath method |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
IEC 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60998-2-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
IEC 60512-13-1:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-1: Mechanical operation tests - Test 13a: Engaging and separating forces |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |