• IEC TS 60076-23:2018

    Current The latest, up-to-date edition.

    Power transformers - Part 23: DC magnetic bias suppression devices

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  09-01-2018

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Service conditions
    5 Selection principle
    6 DC current-limiting device
    7 DC current-blocking device
    8 Tests
    9 Packing, transportation and storage requirements
    10 Nameplate specification
    11 Technical documentation requirements
    Annex A (informative) - Generation mechanism of DC
            bias current of power transformers caused by
            HVDC system
    Annex B (informative) - Examples of harmful effects
            of DC bias current
    Annex C (informative) - DC current-limiting device
    Annex D (informative) - DC current-blocking device
    Annex E (informative) - Information needed to calculate
            the DC bias current of transformers
    Annex F (informative) - Methods of calculation of DC
            bias current voltage sources
    Annex G (informative) - Application examples

    Abstract - (Show below) - (Hide below)

    IEC TS 60076-23:2018(E) specifies requirements for devices for the suppression of DC magnetic bias of power transformers and convertor transformers. It includes requirements for service conditions, structures, testing, packing, transport and storage.
    The devices are connected to neutral points of power transformers and converter transformers to suppress DC bias current in the case an HVDC system is operated in monopole ground return mode or bipolar unbalanced mode. In the case of dedicated metallic return HVDC system, the devices are useful to mitigate DC stray current flowing through power transformers and converter transformers during transient conditions such as DC line fault.
    This document applies to DC magnetic bias suppression devices for operation at frequencies of 50 Hz and 60 Hz on power systems having voltages above 110 kV.

    General Product Information - (Show below) - (Hide below)

    Development Note Stability Date: 2020. (01/2018)
    Document Type Technical Specification
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
    IEC 60068-3-3:1991 Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
    IEC 61071:2017 Capacitors for power electronics
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60168:1994+AMD1:1997+AMD2:2000 CSV Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective