FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Interaction mechanisms and protection methods
6 Description of overall assessment methodology
Annex A (informative) - Classification of effect
Annex B (informative) - Good measurement practice
Annex C (informative) - Computational electromagnetics
Annex D (informative) - System level assessment - HEMP
Annex E (informative) - System level assessment - HPEM
Annex F (informative) - Limitations
Annex G (informative) - Detailed description of low-level
techniques
Annex H (informative) - Detailed description of high-level
test techniques
Annex I (informative) - Data processing and analysis
Bibliography
IEC/TS 61000-5-9:2009(E) is to present a methodology to assess the impact of High-altitude Electromagnetic Pulse (HEMP) and High Power Electromagnetic (HPEM) environments on electronic systems. In this context a system refers to a collection of sub-systems, equipment and components brought together to perform a function. The techniques associated with this methodology and their advantages and disadvantages will be presented along with examples of how the techniques can be applied to evaluate the susceptibility of electronic systems such as those found in installations. This work is closely related to the evaluation of EMC system level susceptibility. The purpose of IEC/TS 61000-5-9:2009 is to provide information on available methods for the assessment of system-level susceptibility as a result of HEMP and HPEM environments. The advantages and disadvantages of the methods will be discussed along with examples of how the techniques should be employed. Typical systems have external connections, wired or wireless, and the assessment of these are included within this specification. IEC/TS 61000-5-9:2009 gives general guidance. It does not cover safety issues nor does it conflict with ITU-T efforts concerning the protection of telecommunications equipment. IEC/TS 61000-5-9:2009 has the status of a basic EMC publication in accordance with IEC Guide 107.
Committee |
TC 77/SC 77C
|
DevelopmentNote |
Stability Date: 2018 (11/2017)
|
DocumentType |
Technical Specification
|
Pages |
66
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
DD IEC/TS 61000-5-9:2009 | Identical |
NEN NPR IEC/TS 61000-5-9 : 2009 | Identical |
13/30286075 DC : 0 | BS EN 61000-4-36 ED 1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-36: TESTING AND MEASUREMENT TECHNIQUES - IEMI IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
IEC TS 61000-5-8:2009 | Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure |
PD IEC/TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI |
IEC 61000-4-36:2014 | Electromagnetic compatibility (EMC) - Part 4-36: Testing and measurement techniques - IEMI immunity test methods for equipment and systems |
DD IEC/TS 61000-5-8:2009 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure |
BS IEC 61000-4-36:2014 | Electromagnetic compatibility (EMC) Testing and measurement techniques. IEMI immunity test methods for equipment and systems |
AEP-41 VOL 4 : 2014 | NATO IMPLEMENTATION OF UNIFIED PROTECTION AGAINST ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (UE[3]) - VOLUME 4: SUSCEPTIBILITY OF PLATFORMS, SYSTEMS & EQUIPMENT TO E[3] |
IEC TS 61000-5-10:2017 | Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI |
IEC TR 61000-5-3:1999 | Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts |
IEC GUIDE 107:2014 | Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications |
IEC 61000-2-10:1998 | Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance |
IEC TR 61000-1-5:2004 | Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems |
IEC 61000-2-11:1999 | Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments |
IEC 61000-5-5:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication |
IEC TR 61000-1-3:2002 | Electromagnetic compatibility (EMC) - Part 1-3: General - The effects of high-altitude EMP (HEMP) on civil equipment and systems |
IEC 61000-4-25:2001+AMD1:2012 CSV | Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems |
IEC 61000-4-33:2005 | Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters |
IEC 61000-6-6:2003 | Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment |
IEC 61000-4-24:2015 | Electromagnetic compatibility (EMC) - Part 4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance |
IEC TR 61000-4-35:2009 | Electromagnetic compatibility (EMC) - Part 4-35: Testing and measurement techniques - HPEM simulator compendium |
IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences |
IEC 61000-2-9:1996 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication |
IEC TR 61000-4-32:2002 | Electromagnetic compatibility (EMC) - Part 4-32: Testing and measurement techniques - High-altitude electromagnetic pulse (HEMP) simulator compendium |
IEC 61000-4-23:2016 | Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances |
IEC 61000-5-7:2001 | Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code) |
IEC 61000-2-13:2005 | Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted |
IEC 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.