• There are no items in your cart

IEC TS 61000-5-9:2009

Current

Current

The latest, up-to-date edition.

Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

08-07-2009

€358.68
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Interaction mechanisms and protection methods
6 Description of overall assessment methodology
Annex A (informative) - Classification of effect
Annex B (informative) - Good measurement practice
Annex C (informative) - Computational electromagnetics
Annex D (informative) - System level assessment - HEMP
Annex E (informative) - System level assessment - HPEM
Annex F (informative) - Limitations
Annex G (informative) - Detailed description of low-level
        techniques
Annex H (informative) - Detailed description of high-level
        test techniques
Annex I (informative) - Data processing and analysis
Bibliography

IEC/TS 61000-5-9:2009(E) is to present a methodology to assess the impact of High-altitude Electromagnetic Pulse (HEMP) and High Power Electromagnetic (HPEM) environments on electronic systems. In this context a system refers to a collection of sub-systems, equipment and components brought together to perform a function. The techniques associated with this methodology and their advantages and disadvantages will be presented along with examples of how the techniques can be applied to evaluate the susceptibility of electronic systems such as those found in installations. This work is closely related to the evaluation of EMC system level susceptibility. The purpose of IEC/TS 61000-5-9:2009 is to provide information on available methods for the assessment of system-level susceptibility as a result of HEMP and HPEM environments. The advantages and disadvantages of the methods will be discussed along with examples of how the techniques should be employed. Typical systems have external connections, wired or wireless, and the assessment of these are included within this specification. IEC/TS 61000-5-9:2009 gives general guidance. It does not cover safety issues nor does it conflict with ITU-T efforts concerning the protection of telecommunications equipment. IEC/TS 61000-5-9:2009 has the status of a basic EMC publication in accordance with IEC Guide 107.

Committee
TC 77/SC 77C
DevelopmentNote
Stability Date: 2018 (11/2017)
DocumentType
Technical Specification
Pages
66
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
DD IEC/TS 61000-5-9:2009 Identical
NEN NPR IEC/TS 61000-5-9 : 2009 Identical

13/30286075 DC : 0 BS EN 61000-4-36 ED 1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-36: TESTING AND MEASUREMENT TECHNIQUES - IEMI IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS
IEC TS 61000-5-8:2009 Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure
PD IEC/TS 61000-5-10:2017 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI
IEC 61000-4-36:2014 Electromagnetic compatibility (EMC) - Part 4-36: Testing and measurement techniques - IEMI immunity test methods for equipment and systems
DD IEC/TS 61000-5-8:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure
BS IEC 61000-4-36:2014 Electromagnetic compatibility (EMC) Testing and measurement techniques. IEMI immunity test methods for equipment and systems
AEP-41 VOL 4 : 2014 NATO IMPLEMENTATION OF UNIFIED PROTECTION AGAINST ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (UE[3]) - VOLUME 4: SUSCEPTIBILITY OF PLATFORMS, SYSTEMS & EQUIPMENT TO E[3]
IEC TS 61000-5-10:2017 Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI

IEC TR 61000-5-3:1999 Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts
IEC GUIDE 107:2014 Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications
IEC 61000-2-10:1998 Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance
IEC TR 61000-1-5:2004 Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems
IEC 61000-2-11:1999 Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments
IEC 61000-5-5:1996 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication
IEC TR 61000-1-3:2002 Electromagnetic compatibility (EMC) - Part 1-3: General - The effects of high-altitude EMP (HEMP) on civil equipment and systems
IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
IEC 61000-4-33:2005 Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters
IEC 61000-6-6:2003 Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment
IEC 61000-4-24:2015 Electromagnetic compatibility (EMC) - Part 4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance
IEC TR 61000-4-35:2009 Electromagnetic compatibility (EMC) - Part 4-35: Testing and measurement techniques - HPEM simulator compendium
IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences
IEC 61000-2-9:1996 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication
IEC TR 61000-4-32:2002 Electromagnetic compatibility (EMC) - Part 4-32: Testing and measurement techniques - High-altitude electromagnetic pulse (HEMP) simulator compendium
IEC 61000-4-23:2016 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
IEC 61000-5-7:2001 Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code)
IEC 61000-2-13:2005 Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted
IEC 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.