• IEEE 1234-2007

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    IEEE Guide for Fault Locating Techniques on Shielded Power Cable Systems

    Available format(s):  PDF

    Superseded date:  01-07-2019

    Language(s):  English

    Published date:  12-07-2007

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Overview
      1.1 General
      1.2 Scope
      1.3 Purpose
    2 Normative references
    3 Definitions, acronyms, and abbreviations
      3.1 Definitions
      3.2 Acronyms and abbreviations
    4 Safety
      4.1 Safety practices
      4.2 Responsibility
      4.3 Precautions
      4.4 Grounding
    5 Cable system fault characteristics
      5.1 Radial distribution
      5.2 Network distribution
      5.3 Cable system faults
    6 Cable system fault locating
      6.1 Fault-locating preferences chart
      6.2 Sectionalizing
      6.3 Insulation Resistance
      6.4 Time domain reflectometry
      6.5 Capacitive discharge (thumping)
      6.6 Burning (fault conditioning)
      6.7 Surge arc reflection
      6.8 Burn arc reflection
      6.9 Surge pulse reflection
      6.10 Decay method
      6.11 Bridge techniques
      6.12 Tracing/locating/pinpointing
    Annex A (informative) Bibliography
    Annex B (informative) First response cable system fault
            location in URD
    Annex C (informative) Fault location in network feeders
          C.1 Fault tracing
          C.2 TDR Assisted fault location
    Annex D (informative) Fault location on cable systems with
            concentric neutral corrosion
    Annex E (informative) Recommended minimum of fault-locating tools

    Abstract - (Show below) - (Hide below)

    Applies to medium-voltage distribution cables. Medium-voltage distribution systems generally operate at system voltages above 1 kV and up to 34.5 kV nominal.

    General Product Information - (Show below) - (Hide below)

    Committee Insulated Conductors
    Development Note Supersedes IEEE DRAFT 1234. (12/2007)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE 510-1983 IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    IEEE 80-2013 REDLINE IEEE Guide for Safety in AC Substation Grounding
    IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above
    IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective