• Shopping Cart
    There are no items in your cart

IEEE 1815.1-2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

IEEE Standard for Exchanging Information Between Networks Implementing IEC 61850 and IEEE Std 1815(TM) [Distributed Network Protocol (DNP3)]

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

16-12-2016

Withdrawn date

26-03-2026

€264.29
Excluding VAT

1. Overview
2. Normative references
4. Conceptual architecture
5. Use cases for configuring the gateway
6. Mapping of a device-oriented information
    model to DNP3
7. Mapping of data structure
8. Mapping of abstract communications service
    interface (IEC 61850-7-2:2010)
9. Describing the DNP3/IEC 61850 mapping using
    XML
10. Security Requirements
Annex A (normative) - Leaf level mapping rules and
        conformance table
Annex B (informative) - Recommended implementation
        levels
Annex C (informative) - Recommended mapping of IINs
        to IEC 61850-7-4 ed2.0 [B3]
Annex D (informative) - Time synchronization security
Annex E (informative) - Example XML files
Annex F (informative) - Mapping to NISTIR 7628 [B9]
Annex G (informative) - Bibliography

Defines the standard approach for mapping between IEEE Std 1815 [TM], IEEE Standard for Electric Power Systems Communications - Distributed Network Protocol (DNP3) and IEC 61850, Communication networks and systems for power utility automation.

Committee
Power System Communications and Cybersecurity
DocumentType
Standard
ISBN
978-1-5044-0598-0
Pages
368
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn

EN 61400-25-4:2017 Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile
CEI EN 61400-25-4 : 2009 WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE
I.S. EN 61400-25-4:2017 WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE
IEEE 2030.100-2017 IEEE Recommended Practice for Implementing an IEC 61850-Based Substation Communications, Protection, Monitoring, and Control System

IEC 61850-5:2013 Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models
IEC 61850-7-2:2010 Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
IEC TS 62351-3:2007 Power systems management and associated information exchange - Data and communications security - Part 3: Communication network and system security - Profiles including TCP/IP
IEC TS 62351-6:2007 Power systems management and associated information exchange - Data and communications security - Part 6: Security for IEC 61850
IEC TS 62351-4:2007 Power systems management and associated information exchange - Data and communications security - Part 4: Profiles including MMS
IEC 61850-6:2009 Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
ISO/IEC 8802-3:2000 Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
IEEE 1686-2007 IEEE Standard for Substation Intelligent Electronic Devices (IEDs) Cyber Security Capabilities
IEC TS 62351-5:2013 Power systems management and associated information exchange - Data and communications security - Part 5: Security for IEC 60870-5 and derivatives
IEEE C37.238-2011 IEEE Standard Profile for Use of IEEE 1588 Precision Time Protocol in Power System Applications
IEC TR 61850-90-5:2012 Communication networks and systems for power utility automation - Part 90-5: Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118
IEC 61850-8-1:2011 Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3
IEC 61850-9-2:2011 Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3
IEEE 1686-2013 IEEE Standard for Intelligent Electronic Devices Cyber Security Capabilities
IEC 61850-7-4:2010 Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
IEC 61850-7-3:2010 Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes
IEEE 1815-2012 REDLINE IEEE Standard for Electric Power Systems Communications-Distributed Network Protocol (DNP3)
IEC TS 62351-8:2011 Power systems management and associated information exchange - Data and communications security - Part 8: Role-based access control

€264.29
Excluding VAT