IEEE 776-1992
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Recommended Practice for Inductive Coordination of Electric Supply and Communication Lines
25-03-2019
English
30-11-1992
1 Scope
2 References
3 General
3.1 Inductive interference
3.2 Need for coordination
3.3 Mutual responsibility of parties involved
4 The inductive environment
4.1 Guidelines for an acceptable environment
4.2 Methods of measurement
4.3 Methods of prediction
5 Coordination within the inductive environment
5.1 General coordination methods
5.2 Specific coordination methods
6 Administrative methods and procedures
6.1 Intercompany meetings and contacts
6.2 Mitigation of specific interference cases
7 Bibliography
Annex A Example calculations
A.1 Prediction calculations
A.2 Mitigation calculations
Annex B Decibel, power, and C-message noise
Addresses the inductive environment that exists in the vicinity of electric power and wire-line telecommunications systems and the interfering effect that may be produced. Gives advice for the control or modification of the environment and the susceptibility of the affected systems in order to maintain an acceptable level of interference.
Committee |
Power System Communications and Cybersecurity
|
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
PD IEC/TR 61000-3-6:2008 | Electromagnetic compatibility (EMC) Limits. Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems |
IEEE 487.1-2014 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of On-Grid Isolation Equipment |
IEC TR 62001-2:2016 | High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 2: Performance |
BS IEC 1000-3.6 : 1996 | ELECTROMAGNETIC COMPATIBILITY (EMC) - LIMITS - ASSESSMENT OF EMISSION LIMITS FOR DISTORTING LOADS IN MV AND HV POWER SYSTEMS - BASIC EMC PUBLICATION |
PD IEC/TR 62001-2:2016 | High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Performance |
07/30164322 DC : 0 | BS EN 61000-3-6 ED.2 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-6: ASSESSMENT OF HARMONIC EMISSION LIMITS FOR THE CONNECTION OF DISTORTING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS |
IEEE C62.23-1995 | IEEE Application Guide for Surge Protection of Electric Generating Plants |
CSA C22.3 No. 3 : 1998 | ELECTRICAL COORDINATION |
DD IEC/PAS 62001:2004 | Guide to the specification and design evaluation of a.c. filters for HVDC systems |
IEEE DRAFT 519.1 : D9A 2004 | GUIDE FOR APPLYING HARMONIC LIMITS ON POWER SYSTEMS |
IEEE 1137-1991 | IEEE Guide for the Implementation of Inductive Coordination Mitigation Techniques and Application |
IEC PAS 62001:2004 | Guide to the specification and design evaluation of a.c. filters for HVDC systems |
IEEE 1124 : 2003 | GUIDE FOR ANALYSIS AND DEFINITION OF DC SIDE HARMONIC PERFORMANCE OF HVDC TRANSMISSION SYSTEMS |
IEC TR 61000-3-6:2008 | Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems |
CSA C22.3 No. 3 : 1998 : INC : UPD 2 : 2002 : R2013 | ELECTRICAL COORDINATION |
IEEE DRAFT 1124 : D8 DEC 97 | DRAFT GUIDE FOR ANALYSIS AND DEFINITION OF DC SIDE HARMONIC PERFORMANCE OF HVDC TRANSMISSION SYSTEMS |
CSA C22.3 No. 3 : 1998:R2007 | ELECTRICAL COORDINATION |
IEEE 487-2015 | IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations |
IEEE 487-2007 | IEEE Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply Locations |
CSA C61000.3.6 : 2009 : R2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-6: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF DISTORTING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS |
CSA C61000.3.6 : 2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-6: LIMITS - ASSESSMENT OF EMISSION LIMITS FOR THE CONNECTION OF DISTORTING INSTALLATIONS TO MV, HV AND EHV POWER SYSTEMS |
IEEE 81-1983 | IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System Part 1: Normal Measurements |
IEEE 487-2015 | IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations |
IEEE 81-2012 | IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System |
IEEE 487-1992 | IEEE Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Power Stations |
IEEE 1137-1991 | IEEE Guide for the Implementation of Inductive Coordination Mitigation Techniques and Application |
IEEE 789-1988 | IEEE Standard Performance Requirements for Communications and Control Cables for Application in High Voltage Environments |
IEEE 789-2013 | IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments |
IEEE 367-1987 | IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault |
IEEE 820-1984 | IEEE Standard Telephone Loop Performance Characteristics |
IEEE 367-2012 | IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.