IEEE C37.016-2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Standard for AC High Voltage Circuit Switchers rated 15.5kV through 245kV
11-10-2021
English
06-06-2007
1 Overview
1.1 Scope
1.2 Normative references
2 Usual and unusual service conditions
2.1 Usual service conditions
2.2 Unusual service conditions
3 Definitions
3.1 General definitions
3.2 Definitions relating to gas and vacuum tightness
4 Rating
4.1 Rated maximum voltage (U[r])
4.2 Rated insulation level
4.3 Rated power frequency (f[r])
4.4 Rated continuous current (I[r])
4.5 Rated short-time withstand current (I[k])
4.6 Rated peak withstand current (I[p])
4.7 Rated short-time withstand current duration (t[k])
4.8 Rated control voltage of operating devices and of auxiliary
and control circuits (U[a])
4.9 Rated control frequency of operating devices and auxiliary
circuits
4.10 Rated pressures of compressed gas supply for insulation,
operation, and/or interruption
4.11 Rated primary-bus fault breaking current (I[SF])
4.12 TRV related to the rated primary-bus fault breaking current
4.13 Rated transformer-limited fault breaking current (I[tf])
4.14 Rated TRV related to the transformer-limited fault
breaking current
4.15 Rated short-circuit making current (I[m])
4.16 Rated operating sequence
4.17 Rated load switching current
4.18 Rated capacitive switching currents
4.19 Rated time quantities
4.20 Mechanical operations endurance
4.21 Rated static terminal load
4.22 Rated ice-breaking ability
5 Design and construction
5.1 Requirements for gases in circuit switchers
5.2 Grounding of circuit switchers
5.3 Auxiliary equipment
5.4 Dependent power closing
5.5 Stored energy closing
5.6 Low- and high-pressure interlocking devices
5.7 Nameplates
5.8 Interlocking devices
5.9 Position indication
5.10 Creepage distances
5.11 Gas and vacuum tightness
5.12 Pressurized components
5.13 Disconnect operation
6 Design tests
6.1 General
6.2 Dielectric tests
6.3 Radio interference voltage tests
6.4 Measurement of resistance of main circuit
6.5 Temperature-rise tests
6.6 Short-time withstand current and peak withstand current tests
6.7 Outdoor enclosure performance
6.8 Gas, vacuum and liquid tightness tests
6.9 Electromagnetic compatibility (EMC) tests
6.10 Mechanical and environmental tests
6.11 Test to prove operation under severe ice conditions
6.12 Static terminal load test
6.13 Miscellaneous provisions for making, breaking, and
switching tests
6.14 Test circuits for short-circuit making and breaking tests
6.15 Short-circuit test quantities
6.16 Short-circuit test procedure
6.17 Basic short-circuit test duties
6.18 Single-phase tests
6.19 Capacitive current-switching tests
6.20 Pressurized components containing insulating gases with
absolute pressures greater than 208 kPa
7 Routine tests
7.1 Dielectric test on auxiliary and control circuits
7.2 Measurement of resistance of main circuit
7.3 Tightness test
7.4 Design and visual checks
7.5 Mechanical operating tests
7.6 Porcelain and nonceramic components with absolute
pressures greater than 208 kPa
Annex A (informative) Bibliography
Pertains to ac circuit switchers designed for outdoor installation and for rated power frequencies of 50 Hz and 60 Hz and rated maximum voltages of 15.5 kV through 245 kV.
Committee |
Switchgear
|
DevelopmentNote |
Supersedes IEEE DRAFT C37.016. (10/2007)
|
DocumentType |
Standard
|
Pages |
82
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy |
17/30368300 DC : 0 | BS EN 62271-107 ED.3.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV |
IEEE 1268-2005 | IEEE Guide for Safety in the Installation of Mobile Substation Equipment |
IEEE C37.100.2-2018 | IEEE Standard for Common Requirements for Testing of AC Capacitive Current Switching Devices over 1000 V |
BS EN 62271-107:2012 | High-voltage switchgear and controlgear Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV |
09/30213777 DC : 0 | BS EN 62271-107 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV |
IEEE C37.06-2009 | IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V |
IEEE C37.06.1-2017 | IEEE Recommended Practice for Preferred Ratings for High-Voltage(>1000 volts) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise Times |
CEI EN 62271-107 : 2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV |
UNE-EN 62271-107:2012 | High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV |
I.S. EN 62271-107:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012 (EQV)) |
IEEE C37.10-2011 REDLINE | IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker Failures |
IEC 62271-107:2012 | High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV |
EN 62271-107:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 107: ALTERNATING CURRENT FUSED CIRCUIT-SWITCHERS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-107:2012) |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEEE C37.083-1999 | IEEE Guide for Synthetic Capacitive Current Switching Tests of AC High-Voltage Circuit Breakers |
ASME PV CODE 8 DIV 2 : 2017 | BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 2- ALTERNATIVE RULES |
IEEE C37.90.1-2002 | IEEE Standard Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEEE C37.081-1981 | IEEE Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.011-2005 | IEEE Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers |
IEEE/ANSI C37.06-2000 | American National Standard for AC High-Voltage Circuit Breakers - Rated on a Symmetrical Current Basis - Preferred Ratings and Related Required Capabilities |
IEEE/IEC C37.60-2012 | IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV |
IEEE 4-1995 | IEEE Standard Techniques for High-Voltage Testing |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
ASME PV CODE 8 DIV 1 : 2017 | BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 1 |
NEMA 250 : 2014 | ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM) |
IEC 60427:2000 | Synthetic testing of high-voltage alternating current circuit-breakers |
ASME PV CODE 8 DIV 3 : 2017 | BPVC Section VIII-BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS - ALTERNATIVE RULES FOR CONSTRUCTION OF HIGH PRESSURE VESSELS |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE C37.60-2003 | IEEE Standard Requirements for Overhead, Pad Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV |
IEEE 1247 : 2005 | INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V |
IEEE C37.011-2011 REDLINE | IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers |
ASTM D 2472 : 2015 : REDLINE | Standard Specification for Sulfur Hexafluoride |
IEEE C37.06-2009 | AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
NEMA CC1 : 2009(R2015) | ELECTRIC POWER CONNECTORS FOR SUBSTATIONS |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEEE C37.100-1992 | IEEE Standard Definitions for Power Switchgear |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.