IEEE C37.46-2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
IEEE Standard Specifications for High-Voltage (>1000 V) Expulsion and Current-Limiting Power Class Fuses and Fuse Disconnecting Switches
English
29-10-2010
19-10-2021
1. Overview
2. Normative references
3. General rating information
4. Design test requirements
5. Time-current-characteristic requirements for power
class fuse refill units, fuse units, and fuse links
6. Conformance tests
7. Construction requirements
8. Nameplate marking
9. Application, operation, and maintenance guidelines
Annex A (informative) - Bibliography
Describes specifications for high voltage (above 1000 volts) expulsion and current-limiting type power class fuses, and accessories. All of these devices are intended for use on alternating current systems.
| Committee |
Switchgear
|
| DevelopmentNote |
Supersedes ANSI C37.46. (11/2010)
|
| DocumentType |
Standard
|
| Pages |
28
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Superseded
|
| Supersedes |
| IEEE 3004.8-2016 | IEEE Recommended Practice for Motor Protection in Industrial and Commercial Power Systems |
| IEEE C37.96-2012 | IEEE Guide for AC Motor Protection |
| IEEE C37.48.1-2002 | IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38kV |
| MIL-DTL-32483 Base Document:2013 | Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard |
| MIL-DTL-917 Revision F:2014 | Electric Power Equipment, Basic Requirements for |
| IEC TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
| IEEE C37.302-2015 | IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC |
| IEEE C37.45-2007 | IEEE Standard Specifications for High Voltage Distribution Class Enclosed Single-Pole Air Switches with Rated Voltages from 1 through 8.3 kV |
| UFC 3-550-01 : CHANGE 1 | UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION |
| IEEE C37.47-2011 | IEEE Standard Specifications for High-Voltage (>1000 V) Distribution Class Current-Limiting Type Fuses and Fuse Disconnecting Switches |
| PD IEC/TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
| IEEE C37.74-2014 REDLINE | IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV |
| IEEE C37.42-2009 | IEEE Standard Specifications for High-Voltage (> 1000 V) Expulsion-Type Distribution-Class Fuses, Fuse and Disconnecting Cutouts, Fuse Disconnecting Switches, and Fuse Links, and Accessories Used with These Devices |
| IEEE C37.48.1-2011 REDLINE | IEEE Guide for the Application, Operation, and Coordination of High-Voltage (>1000 V) Current-Limiting Fuses |
| IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
| IEEE C37.42-2009 | IEEE Standard Specifications for High-Voltage (> 1000 V) Expulsion-Type Distribution-Class Fuses, Fuse and Disconnecting Cutouts, Fuse Disconnecting Switches, and Fuse Links, and Accessories Used with These Devices |
| IEEE C37.10.1-2000 | IEEE Guide for the Selection of Monitoring for Circuit Breakers |
| IEC 60282-1:2009+AMD1:2014 CSV | High-voltage fuses - Part 1: Current-limiting fuses |
| IEEE C37.48-2005 | IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories |
| IEEE C37.43-2008 | IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors |
| IEEE C37.45-2007 | SPECIFICATIONS FOR DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES |
| IEEE C37.40-2003 | IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories |
| IEEE C37.41-2008 REDLINE | IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices |
| IEEE C37.45-2007 | IEEE Standard Specifications for High Voltage Distribution Class Enclosed Single-Pole Air Switches with Rated Voltages from 1 through 8.3 kV |
| IEEE C37.48.1-2002 | IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38kV |
| IEC 60282-2:2008 | High-voltage fuses - Part 2: Expulsion fuses |
| IEEE C37.47-2011 | DISTRIBUTION FUSE DISCONNECTING SWITCHES, FUSE SUPPORTS, AND CURRENT LIMITING FUSES, SPECIFICATIONS FOR (INCLUDES SUPPLEMENT ANSI C37.47A 1983), |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.