• IEEE C57.123-2010 REDLINE

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    IEEE Guide for Transformer Loss Measurement

    Available format(s):  PDF

    Superseded date:  18-02-2020

    Language(s):  English

    Published date:  03-08-2010

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Overview
    2. Normative references
    3. Transformer no-load losses
    4. Transformer load losses
    5. Advanced measuring systems
    6. Specified tolerances on losses
    7. Traceability and calibration
    8. Grounding, shielding, and safety
    Annex A (informative) - Bibliography

    Abstract - (Show below) - (Hide below)

    Describes background information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, and load losses of power and distribution transformers.

    General Product Information - (Show below) - (Hide below)

    Committee Transformers
    Development Note Supersedes IEEE DRAFT C57.123. (01/2003)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS PD IEC TS 60076-19 : 2013 POWER TRANSFORMERS - PART 19: RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS
    IEEE C57.16-2011 IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors
    IEEE 1377-2012 IEEE Standard for Utility Industry Metering Communication Protocol Application Layer (End Device Data Tables)
    IEC TS 60076-19:2013 Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
    CEI CLC/TR 50462 : 2009 RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS
    CLC/TR 50462:2008 Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
    S.R. CLC/TR 50462:2008 RULES FOR THE DETERMINATION OF UNCERTAINTIES IN THE MEASUREMENT OF THE LOSSES ON POWER TRANSFORMERS AND REACTORS
    IEEE C57.12.90-2015 REDLINE IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE 1052-2018 IEEE Guide for Specification of Transmission Static Synchronous Compensator (STATCOM) Systems

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C57.12.91-2001 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
    IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
    IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.15-2009 REDLINE IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators
    IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    IEEE C57.12.00-2006 IEEE Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.12.91-2011 IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective