IEEE C62.48 : 2005

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

GUIDE ON INTERACTIONS BETWEEN POWER SYSTEM DISTURBANCES AND SURGE-PROTECTIVE DEVICES

Available format(s)

Hardcopy , PDF

Superseded date

20-04-2021

Superseded by

IEEE C62.41.3-2020

Language(s)

English

Published date

01-01-2005

€78.50
Excluding VAT

1 Overview
  1.1 Scope
  1.2 Purpose
2 Normative references
3 Definitions
4 Power system disturbances
  4.1 Surges
  4.2 Swells
  4.3 Temporary overvoltages
  4.4 Notches
  4.5 Sags
  4.6 Temporary undervoltages
  4.7 Harmonics
  4.8 Noise
  4.9 Voltage magnification
5 Interactions of power system disturbances on SPDs
  5.1 Response to voltage surges
  5.2 Response to swells
  5.3 Response to TOVs
  5.4 Response to notches
  5.5 Response to sags
  5.6 Response to temporary undervoltages
  5.7 Response to harmonics
  5.8 Response to noise
  5.9 Response to voltage magnification
6 Interactions of SPDs on power system disturbances
  6.1 Benefits for downstream and upstream loads
  6.2 Partial loss of power with voltage-switching devices
  6.3 Surge current introduction into a facility
  6.4 Voltage oscillations caused by SPDs
  6.5 Effects of inductance between SPDs
  6.6 SPD failure-mode effects on power systems
  6.7 Effects of SPD peripheral components on power systems
  6.8 Effect of added filter on neutral-ground voltage
Annex A (informative) Bibliography
Annex B (informative) Description of environment
      B.1 The steady-state environment
      B.2 Sources of power system disturbances
Annex C (informative) Glossary

Specifies the effects on SPDs of power system disturbances occurring in these low-voltage ac power circuits. The disturbances are not limited to surges. The effects of the presence and operation of SPDs on the quality of power available to the connected loads are described. The interaction among multiple SPDs on the same circuit is also described.

DevelopmentNote
Supersedes IEEE DRAFT C62.48. (11/2005)
DocumentType
Standard
Pages
30
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

95/210789 DC : DRAFT AUG 1995 IEC 61000-5-6 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5: MITIGATION METHODS AND INSTALLATION GUIDELINES - SECTION 6: MITIGATION OF EXTERNAL INFLUENCES - TECHNICAL REPORT TYPE 2
IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences
IEEE C62.72-2007 IEEE Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power Circuits
PD IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC). Installation and mitigation guidelines Mitigation of external EM influences

IEEE C62.92.4-2014 IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems--Part IV: Distribution
ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.