IEEE DRAFT C37.13.1 : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DEFINITE PURPOSE SWITCHING DEVICES FOR USE IN METAL-ENCLOSED LOW-VOLTAGE POWER CIRCUIT BREAKER SWITCHGEAR
Hardcopy , PDF
English
18-10-2006
1 Overview
1.1 Scope
1.2 Purpose
2 Normative references
3 Definitions
4 Normal service conditions
5 Ratings
5.1 General
5.2 Rated maximum voltage
5.3 Rated power frequency
5.4 Rated continuous current
5.5 Rated short-circuit withstand current
5.6 Rated control voltage
6 Functional components
6.1 Nameplate(s)
6.2 Contact position indicator
6.3 Stored energy indicator (for stored energy type closing
mechanisms only)
6.4 DPS device retention and locking
6.5 Interlocks
6.6 Secondary disconnect devices
6.7 Blocking/Rejection interlocks
7 Temperature limitations and classification of insulating materials
7.1 Temperature limits
7.2 Limits of temperature rise
7.3 Classification of insulating materials
8 Tests
8.1 Design (type) tests
8.2 Production (routine) tests
8.3 Field dielectric test
9 Application Guide
9.1 General
9.2 Application of DPS devices to full-voltage starting
and running duty of three-phase 60 Hz motors
9.3 Application of DPS devices for capacitance switching
9.4 Service conditions affecting DPS device applications
9.5 Repetitive duty operations and normal maintenance
Annex A (informative) Bibliography
Presents requirements for low-voltage (600 V ac and below) definite purpose switching devices (other than power circuit breakers) for use in metal-enclosed, low-voltage, power circuit breaker switchgear described in IEEE Std C37.20.1-2002.
| DocumentType |
Draft
|
| Pages |
21
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Superseded
|
| SupersededBy |
| IEEE C37.20.1-2015 | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
| IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
| UL 248-8:3ED 2011-05-13 | Low-Voltage Fuses - Part 8: Class J Fuses |
| IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
| UL 248-12:3ED 2011-05-13 | Low-Voltage Fuses - Part 12: Class R Fuses |
| IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) (Color Book® Series) |
| IEEE C37.13-2015 REDLINE | IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures |
| UL 248-10:3ED 2011-05-13 | Low-Voltage Fuses - Part 10: Class L Fuses |
| NEMA ICS 1 : 2000(R2015) | INDUSTRIAL CONTROL AND SYSTEMS: GENERAL REQUIREMENTS |
| IEEE C37.16-2009 | IEEE Standard for Preferred Ratings,Related Requirements, and Application Recommendations for Low-Voltage AC (635 V and below)and DC (3200 V and below) Power Circuit Breakers |
| NEMA ICS 2:2008 | Controllers, Contactors and Overload Relays Rated 600 V |
| IEEE C37.17-2012 | IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers |
| IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |