1 Overview
    1.1 General Scope
    1.2 Description of Fuse Enclosure Packages (FEP)
          Using Expulsion Type Indoor Power Class Fuses
    1.3 Description of Fuse Enclosure Packages (FEP)
          Using Current-Limiting Type Indoor Distribution
          and Power Class Fuses
2 References
    2.1 Referenced American National Standards
    2.2 Other Referenced Standards
3 General Application Guidelines for all Fuse Types
    3.1 Introduction
    3.2 Service conditions
    3.3 Selection of class and type of fuse
    3.4 Clearances and Spacing
    3.5 Fuse Position
    3.6 Noise Level
    3.7 Selection of Fuse Voltage Rating (See clauses
          4.4.2.2. and 4.4.3.2 for specific guidelines
          for Voltage Rating Selection for Capacitor
          Fuses)
    3.8 Selection of Continuous Current Rating (All
          Applications Except Capacitor Fuses and Fuses
          Used In Enclosures - see clauses 4.2, 4.3 and
          4.4)
    3.9 Selection of Interrupting Rating
    3.10 Fuse Coordination Procedure
    3.11 Coordination for Motor Starter Fuses
4 Additional Application Guidelines for Specific
    Devices
    4.1 Current Limiting Fuses
    4.2 Current Limiting Fuses Used in Fuse Enclosure
          Packages
    4.3 Expulsion Fuses in Enclosures
    4.4 External Fuses for Shunt Capacitors
Figure 1 - An example of capacitor case rupture curve
           characteristics
5 Operation Guidelines for Various Fuse Types
    5.1 Use of Nonexpendable Cap on Expendable-Cap
          Cutouts
    5.2 Operating Speed
    5.3 Locking or Latching of Fuses, Blades or Links
          Closed Position
    5.4 Fuseholder Position
    5.5 Voltage Withstand of Blown Fuses
    5.6 Replacement and Handling of Fuses
    5.7 Replacement of Exhaust Control Device
    5.8 Operation of Energized Fuses
    5.9 Storing Spare Fuse Units and Replaceable Parts
6 Additional Operation Guidelines for Specific Devices
    6.1 Capacitor Fuses
    6.2 Liquid-Submerged Expulsion Fuses in Enclosures
7 Maintenance For All Fuse Types
    7.1 Safety Precautions
    7.2 Frequency of Maintenance
    7.3 Inspection of Fuse or Switching Device
    7.4 Inspection of Fuse Links in Distribution
          Cutouts
8 Additional Maintenance Guidelines for Specific
    Devices
    8.1 Capacitor Fuses
    8.2 Liquid-Submerged Expulsion Fuses in Enclosures
    8.3 Distribution Oil Cutouts

Gives information on application, operation and maintenance of high-voltage fuses, distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on alternating-current distribution systems.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy

IEEE C37.46-2010 FOR HIGH VOLTAGE EXPULSION AND CURRENT-LIMITING TYPE POWER CLASS FUSES AND FUSE DISCONNECTING SWITCHES
IEEE C37.42-2009 SWITCHGEAR DISTRIBUTION CUTOUTS AND FUSE LINKS SPECIFICATIONS
IEC 60282-1:2009+AMD1:2014 CSV High-voltage fuses - Part 1: Current-limiting fuses
IEEE 1036-2010 IEEE Guide for the Application of Shunt Power Capacitors
ANSI C37.44 : 1981 AMERICAN NATIONAL STANDARD SPECIFICATIONS FOR DISTRIBUTION OIL CUTOUTS AND FUSE LINKS
IEEE C37.99-2012 IEEE Guide for the Protection of Shunt Capacitor Banks
IEEE C37.45-2007 SPECIFICATIONS FOR DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES
IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
IEEE 18-2012 IEEE Standard for Shunt Power Capacitors
IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses
IEEE C37.47-2011 DISTRIBUTION FUSE DISCONNECTING SWITCHES, FUSE SUPPORTS, AND CURRENT LIMITING FUSES, SPECIFICATIONS FOR (INCLUDES SUPPLEMENT ANSI C37.47A 1983),

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.