• IEEE C37.42-2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    SWITCHGEAR DISTRIBUTION CUTOUTS AND FUSE LINKS SPECIFICATIONS

    Available format(s):  Hardcopy, PDF

    Superseded date:  29-01-2010

    Language(s):  English

    Published date:  01-01-2009

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Scope
    2. Referenced standards
    3. Distribution class open, enclosed and open-link
       fuses and cutouts and fuse disconnecting switches
    4. Fuse links for distribution class open, enclosed,
       and open-link fuses and cutouts

    Abstract - (Show below) - (Hide below)

    Sets up specifications for high voltage (above 1000 volts) expulsion type distribution class fuses, cutouts, fuse disconnecting switches, fuse links and associated accessories. All of these devices are intended for use on alternating current distribution systems.

    General Product Information - (Show below) - (Hide below)

    Development Note Redesignated as IEEE C37.42. (03/2010)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
    IEEE DRAFT C37.48 : D5 NOV 96 GUIDE FOR APPLICATION, OPERATION AND MAINTENANCE OF HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES
    IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    IEEE DRAFT C37.48.1 : D13 2000 DRAFT GUIDE FOR THE OPERATION, CLASSIFICATION, APPLICATION AND COORDINATION OF CURRENT-LIMITING FUSES WITH RATED VOLTAGES 1-38 KV
    A-A-55498 Revision F:2017 FUSE LINK, ELECTRICAL, TYPE T (SLOW)
    A-A-55497 Revision F:2017 FUSE LINK, ELECTRICAL, TYPE K (FAST)
    IEEE C37.48-2005 IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    IEEE DRAFT C37.108 : D6 98 DRAFT GUIDE FOR THE PROTECTION OF NETWORK TRANSFORMERS
    CSA C310 : 2009 : R2014 DISTRIBUTION CLASS POLYMERIC CUTOUTS
    NEMA SG 2 : 1993 HIGH VOLTAGE FUSES
    ANSI C37.44 : 1981 AMERICAN NATIONAL STANDARD SPECIFICATIONS FOR DISTRIBUTION OIL CUTOUTS AND FUSE LINKS
    CSA C310 : 2009 DISTRIBUTION CLASS POLYMERIC CUTOUTS
    CSA C310 : 2009 : INC : UPD 2 : 2012 DISTRIBUTION CLASS POLYMERIC CUTOUTS
    CSA C233.1 : 1987 GAPLESS METAL OXIDE SURGE ARRESTERS FOR ALTERNATING CURRENT SYSTEMS
    IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
    IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
    IEEE C37.43-2008 IEEE Standard Specifications for High-Voltage Expulsion, Current-Limiting, and Combination-Type Distribution and Power Class External Fuses, with Rated Voltages from 1 kV through 38 kV, Used for the Protection of Shunt Capacitors
    IEEE 551 : 2006 CALCULATING SHORT-CIRCUIT CURRENTS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C37.48-2005 IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    ASME B18.2.2 : 2015 NUTS FOR GENERAL APPLICATIONS: MACHINE SCREW NUTS, HEX, SQUARE, HEX FLANGE, AND COUPLING NUTS (INCH SERIES)
    IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
    IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses