• IEEE DRAFT C57.12.20 : D10C 2004

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    OVERHEAD TYPE DISTRIBUTION TRANSFORMERS, 500 KVA AND SMALLER: HIGH VOLTAGE, 34 500 VOLTS AND BELOW; LOW VOLTAGE, 7970/13 800Y VOLTS AND BELOW

    Available format(s): 

    Withdrawn date:  17-10-2023

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Institute of Electrical & Electronics Engineers

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Overview
      1.1 Scope
      1.2 Purpose
    2 References
    3 Definitions
      3.1 A Fault
      3.2 A Test
      3.3 Back-Up Protection
      3.4 Enclosures
      3.5 Internal Fusible Element
    4 Ratings
      4.1 Kilovolt-Ampere Ratings
      4.2 Voltage Ratings and Tap Ratings
    5 Basic Lightning Impulse Insulation Levels and Dielectric
      Test Levels
      5.1 Basic Lightning Impulse
      5.2 Dielectric Test
    6 Tests
      6.1 General
      6.2 Dielectric Tests
    7 Construction
      7.1 Bushings and Terminals
          7.1.1 Bushings
          7.1.2 Terminals
          7.1.3 Neutral Termination
          7.1.4 Terminal Boards
      7.2 Accessory Equipment
          7.2.1 Tap Changer
          7.2.2 Series-Multiple Connections
          7.2.3 Liquid-Level Marking
          7.2.4 Lifting Lugs
          7.2.5 Relief of Excessive Pressure
          7.2.6 Enclosure Integrity
      7.3 Polarity, Terminal Markings, and Angular Displacement
          7.3.1 Polarity
          7.3.2 Angular Displacement
          7.3.3 Terminal Markings
          7.3.4 Instruction Nameplate
          7.3.5 Kilovolt-Ampere Rating on Tank
          7.3.6 Connections for Shipment by the Manufacturer
      7.4 Oil Preservation
      7.5 Tanks
          7.5.1 Covers and Handholes
          7.5.2 Support Lugs
          7.5.3 Tank Finish
          7.5.4 Tank Grounding Provisions
    8 Storage and Installation
      8.1 Storage
      8.2 Installation
    9 Design Tests for Fault Current Capability of Overhead
      Distribution Transformer Enclosures
      9.1 Objective
      9.2 General Requirements
      9.3 Tests
      9.4 Test Number 1- An Arcing Fault in an Enclosure
          9.4.1 First Fault
          9.4.2 Second Fault
      9.5 Test Number 2- For Enclosures with Internal Fusible Elements
          9.5.1 "A" Fault
          9.5.2 "B" Fault
      9.6 Test Results
    Tables
    Figures
    Annex A (informative) Auxiliary Mounting Devices
    Figure A.1 Support Lug C
    Figure A.2 Type C Adapter Plates
    Figure A.3 T-Crossarm Hangers and Kickers (T1 and K1)
    Figure A.4 T-Crossarm Hangers and Kickers (T2 and K2)
    Figure A.5 Crossarm Hangers
    Annex B (informative) Bibliography

    Abstract - (Show below) - (Hide below)

    Describes certain electrical, dimensional, and mechanical characteristics and safety features of single and three phase, 60-Hz, mineral oil immersed, self-cooled, overhead type distribution transformers 500 kVA and smaller, High Voltages 34 500 volts and below and Low Voltages 7970/13 800Y volts and below.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Document Type Draft
    Publisher Institute of Electrical & Electronics Engineers
    Status Withdrawn

    Standards Referencing This Book - (Show below) - (Hide below)

    NEMA TR1 : 2013 TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS
    NEMA MG 2:2014 Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators
    IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
    IEEE C135.1-1999 IEEE Standard for Zinc-Coated Steel Bolts and Nuts for Overhead Line Construction
    IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
    IEEE C57.12.31-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity
    IEEE C57.12.70-2011 IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers
    IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
    MIL-STD-209 Revision K:2005 LIFTING AND TIEDOWN PROVISIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective