ISA TR12.13.03 : 2009
Current
The latest, up-to-date edition.
GUIDE FOR COMBUSTIBLE GAS DETECTION AS A METHOD OF PROTECTION
01-01-2009
Foreword
Abstract
Keywords
Introduction
1 Scope
2 References
3 Definitions
4 Fixed installations with otherwise unsuitable equipment
5 Live equipment maintenance
6 Combustible gas detection systems in adequately ventilated
classified areas
Annex A - A permit for electrical work in classified locations
(example)
Annex B - Examples of actions
Combustible gas detection used for process safety management may also be used to provide protection from explosion or fires by minimizing the possibility of an accumulation of combustible gases reaching ignitable levels.
| DocumentType |
Technical Report
|
| PublisherName |
International Society of Automation
|
| Status |
Current
|
| C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
| NFPA 820 : 2016 | FIRE PROTECTION IN WASTEWATER TREATMENT AND COLLECTION FACILITIES |
| C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
| IEC 61511-1:2016+AMD1:2017 CSV | Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and application programming requirements |
| IEC 61779-6:1999 | Electrical apparatus for the detection and measurement of flammable gases - Part 6: Guide for the selection, installation, use and maintenance of apparatus for the detection and measurement of flammable gases |
| ISA TR12.24.01 : 1998 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS CLASSIFIED AS CLASS 1, ZONE 0, ZONE 1, OR ZONE 2 |
| ISA 84.00.01-1 : 2004 | FUNCTIONAL SAFETY: SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRY SECTOR - PART 1: FRAMEWORK, DEFINITIONS, SYSTEM, HARDWARE AND SOFTWARE REQUIREMENTS |
| IEC 61779-2:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5 % methane in air |
| ISA 12.13.04 : 2007 | PERFORMANCE REQUIREMENTS FOR OPEN PATH COMBUSTIBLE GAS DETECTORS |
| FM 6325 : 2007 | PERFORMANCE REQUIREMENTS FOR OPEN PATH COMBUSTIBLE GAS DETECTORS |
| IEC 61779-4:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 4: Performance requirements for group II apparatus indicating up to 100% lower explosive limit |
| ISA 12.13.01 : 2003 | PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS |
| NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
| NFPA 72 : 2016 | NATIONAL FIRE ALARM AND SIGNALING CODE |
| IEC 61779-3:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100 % methane in air |
| ISA RP12.13.02 : 2003 | INSTALLATION, OPERATION, AND MAINTENANCE OF COMBUSTIBLE GAS DETECTION INSTRUMENTS |
| IEC 61779-5:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100 % gas |
| ISA 60079-0 : 2005 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
| IEC 61779-1:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 1: General requirements and test methods |
| NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.