ISO 11542-2:1998
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Plastics Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materials Part 2: Preparation of test specimens and determination of properties
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
19-01-2021
19-11-1998
This part of ISO 11542 specifies the methods of preparation of test specimens and the test methods to be used in determining the properties of PE-UHMW moulding and extrusion materials. Requirements for handling test material and for conditioning both the test material before moulding and the specimens before testing are given here.
Procedures and conditions for the preparation of test specimens and procedures for measuring properties of the materials from which these specimens are made are given. Properties and test methods which are suitable and necessary to characterize PE-UHMW moulding and extrusion materials are listed.
The properties have been selected from the general test methods in ISO 10350-1. Other test methods in wide use for or of particular significance to these moulding and extrusion materials are also included in this part of ISO 11542, as are the designatory properties specified in part 1.
In order to obtain reproducible and comparable test results, it is necessary to use the methods of preparation and conditioning, the specimen dimensions and the test procedures specified herein. Values determined will not necessarily be identical to those obtained using specimens of different dimensions or prepared using different procedures.
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
ONORM EN ISO 11542-2 : 2009 | Identical |
NBN EN ISO 11542-2 : 1999 COR 2008 | Identical |
NEN EN ISO 11542-2 : 1998 C1 2008 | Identical |
NS EN ISO 11542-2 : 1998 AC 2008 | Identical |
I.S. EN ISO 11542-2:1999 | Identical |
PN EN ISO 11542-2 : 2005 AC 2009 | Identical |
SN EN ISO 11542-2 : 1999 CORR 2009 | Identical |
UNI EN ISO 11542-2 : 2001 | Identical |
BS EN ISO 11542-2 : 1999 | Identical |
NF EN ISO 11542-2 : 1999 | Identical |
UNE-EN ISO 11542-2:1999 | Identical |
DIN EN ISO 11542-2:2010-01 | Identical |
BS ISO 5834-4:2005 | Implants for surgery. Ultra-high molecular weight polyethylene Oxidation index measurement method |
17/30360584 DC : 0 | BS ISO 5834-3 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 3: ACCELERATED AGEING METHODS |
ISO 5834-1:2005 | Implants for surgery Ultra-high-molecular-weight polyethylene Part 1: Powder form |
BS EN ISO 15527:2013 | Plastics. Compression-moulded sheets of polyethylene (PEUHMW, PE-HD). Requirements and test methods |
BS ISO 5834-3:2005 | Implants for surgery. Ultra-high-molecular-weight polyethylene Accelerated ageing methods |
I.S. EN ISO 15527:2013 | PLASTICS - COMPRESSION-MOULDED SHEETS OF POLYETHYLENE (PE-UHMW, PE-HD) - REQUIREMENTS AND TEST METHODS (ISO 15527:2010) |
UNE-EN ISO 15527:2014 | Plastics - Compression-moulded sheets of polyethylene (PE-UHMW, PE-HD) - Requirements and test methods (ISO 15527:2010) |
BS EN ISO 23667:2007 | Packaging. Transport packaging for dangerous goods. Rigid plastics and plastics composite IBCs. Compatibility testing |
EN ISO 23667:2007 | Packaging - Transport packaging for dangerous goods - Rigid plastics and plastics composite IBCs - Compatibility testing (ISO 23667:2007) |
BS ISO 5834-2:2011 | Implants for surgery. Ultra-high-molecular-weight polyethylene Moulded forms |
BS ISO 5834-5:2005 | Implants for surgery. Ultra-high molecular weight polyethylene Morphology assessment method |
ISO 5834-5:2005 | Implants for surgery Ultra-high-molecular-weight polyethylene Part 5: Morphology assessment method |
ONORM EN ISO 15527 : 2013 | PLASTICS - COMPRESSION-MOULDED SHEETS OF POLYETHYLENE (PE-UHMW, PE-HD) - REQUIREMENTS AND TEST METHODS (ISO 15527:2010) |
BS ISO 5834-1:2005 | Implants for surgery. Ultra-high-molecular-weight polyethylene Powder form |
I.S. EN ISO 13274:2013 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - PLASTICS COMPATIBILITY TESTING FOR PACKAGING AND IBCS (ISO 13274:2013) |
17/30360578 DC : 0 | BS ISO 5834-1 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 1: POWDER FORM |
DIN ISO 5834-2:2014-02 | IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 2: MOULDED FORMS (ISO 5834-2:2011) |
ASTM F 2759 : 2011 : REDLINE | Standard Guide for Assessment of the Ultra High Molecular Weight Polyethylene (UHMWPE) Used in Orthopedic and Spinal Devices |
DIN EN ISO 23667:2007-10 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - RIGID PLASTICS AND PLASTICS COMPOSITE IBCS - COMPATIBILITY TESTING |
I.S. EN ISO 11542-1:2001 | PLASTICS - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE (PE-UHMW) MOULDING AND EXTRUSION MATERIALS - PART 1: DESIGNATION SYSTEM AND BASIS FOR SPECIFICATIONS |
NBR ISO 5834-1 : 2008 | IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR WEIGHT POLYETHYLENE - PART 1: POWDER FORM |
03/317992 DC : DRAFT DEC 2003 | BS ISO 5834-4 - IMPLANTS FOR SURGERY - ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE - PART 4: MEASUREMENT OF OXIDATION INDEX |
I.S. EN ISO 16101:2004 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - PLASTICS COMPATIBILITY TESTING |
11/30237918 DC : 0 | BS EN ISO 13274 - PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - PLASTICS COMPATIBILITY TESTING FOR PACKAGING AND IBCS |
DIN EN ISO 13274:2014-06 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - PLASTICS COMPATIBILITY TESTING FOR PACKAGING AND IBCS (ISO 13274:2013 + COR. 1:2014) |
04/30101822 DC : DRAFT APR 2004 | ISO 5834-1 - IMPLANTS FOR SURGERY - ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE - PART 1: POWDER FORM |
DIN ISO 5834-1:2007-06 | IMPLANTS FOR SURGERY - ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE - PART 1: POWDER FORM |
BS EN ISO 13274:2013 | Packaging. Transport packaging for dangerous goods. Plastics compatibility testing for packaging and IBCs |
EN ISO 15527:2013 | Plastics - Compression-moulded sheets of polyethylene (PE-UHMW, PE-HD) - Requirements and test methods (ISO 15527:2010) |
DIN EN ISO 16101:2004-12 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - PLASTICS COMPATIBILITY TESTING |
ISO 13274:2013 | Packaging — Transport packaging for dangerous goods — Plastics compatibility testing for packaging and IBCs |
ASTM D 6712 : 2017 : REDLINE | Standard Specification for Ultra-High-Molecular-Weight Polyethylene (UHMW-PE) Solid Plastic Shapes |
I.S. EN ISO 23667:2007 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - RIGID PLASTICS AND PLASTICS COMPOSITE IBCS - COMPATIBILITY TESTING |
17/30360587 DC : 0 | BS ISO 5834-4 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 4: OXIDATION INDEX MEASUREMENT METHOD |
04/30031040 DC : 0 | ISO 5834-3 - IMPLANTS FOR SURGERY - ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE - PART 3: ACCELERATED AGEING METHODS |
ISO 5834-2:2011 | Implants for surgery Ultra-high-molecular-weight polyethylene Part 2: Moulded forms |
NF EN ISO 13274 : 2013 | PACKAGING - TRANSPORT PACKAGING FOR DANGEROUS GOODS - PLASTICS COMPATIBILITY TESTING FOR PACKAGING AND IBCS |
04/30099319 DC : DRAFT APR 2004 | ISO 5834-5 - IMPLANTS FOR SURGERY - ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE - PART 5: MORPHOLOGY ASSESSMENT METHOD |
17/30360581 DC : 0 | BS ISO 5834-2 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 2: MOULDED FORMS |
ISO 15527:2010 | Plastics Compression-moulded sheets of polyethylene (PE-UHMW, PE-HD) Requirements and test methods |
DIN EN ISO 15527:2013-05 | PLASTICS - COMPRESSION-MOULDED SHEETS OF POLYETHYLENE (PE-UHMW, PE-HD) - REQUIREMENTS AND TEST METHODS (ISO 15527:2010) |
ASTM F 648 : 2014 : REDLINE | Standard Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants |
ISO 5834-3:2005 | Implants for surgery Ultra-high-molecular-weight polyethylene Part 3: Accelerated ageing methods |
ISO 16770:2004 | Plastics Determination of environmental stress cracking (ESC) of polyethylene Full-notch creep test (FNCT) |
BS EN ISO 16101:2004 | Packaging. Transport packaging for dangerous goods. Plastics compatibility testing |
ISO 23667:2007 | Packaging Transport packaging for dangerous goods Rigid plastics and plastics composite IBCs Compatibility testing |
ISO 11542-1:2001 | Plastics Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materials Part 1: Designation system and basis for specifications |
ISO 16101:2004 | Packaging Transport packaging for dangerous goods Plastics compatibility testing |
UNE-EN ISO 13274:2014 | Packaging - Transport packaging for dangerous goods - Plastics compatibility testing for packaging and IBCs (ISO 13274:2013) |
EN ISO 11542-1:2001 | Plastics - Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materials - Part 1: Designation system and basis for specifications (ISO 11542-1:2001) |
UNI EN ISO 15527 : 2013 | PLASTICS - COMPRESSION-MOULDED SHEETS OF POLYETHYLENE (PE-UHMW, PE-HD) - REQUIREMENTS AND TEST METHODS |
11/30229855 DC : 0 | BS ISO 5834-4 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 4: OXIDATION INDEX MEASUREMENT METHOD |
17/30360590 DC : 0 | BS ISO 5834-5 - IMPLANTS FOR SURGERY - ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - PART 5: MORPHOLOGY ASSESSMENT METHOD |
BS ISO 16770:2004 | Plastics. Determination of environmental stress cracking (ESC) of polyethylene. Full-notch creep test (FNCT) |
ISO 5834-4:2005 | Implants for surgery Ultra-high-molecular-weight polyethylene Part 4: Oxidation index measurement method |
BS ISO 15527 : 2010 | PLASTICS - COMPRESSION-MOULDED SHEETS OF POLYETHYLENE (PE-UHMW, PE-HD) - REQUIREMENTS AND TEST METHODS |
BS EN ISO 11542-1:2001 | Plastics. Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materials Designation system and basis for specifications |
EN ISO 16101:2004 | Packaging - Transport packaging for dangerous goods - Plastics compatibility testing (ISO 16101:2004) |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
ISO 75-1:2013 | Plastics Determination of temperature of deflection under load Part 1: General test method |
EN ISO 10350 : 1995 | PLASTICS - ACQUISITION AND PRESENTATION OF COMPARABLE SINGLE-POINT DATA |
EN ISO 8256:2004 | Plastics - Determination of tensile-impact strength (ISO 8256:2004) |
ISO 293:2004 | Plastics — Compression moulding of test specimens of thermoplastic materials |
ISO 3167:2014 | Plastics Multipurpose test specimens |
ISO 527-4:1997 | Plastics Determination of tensile properties Part 4: Test conditions for isotropic and orthotropic fibre-reinforced plastic composites |
IEC 60250:1969 | Recommended methods for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials at power, audio and radio frequencies including metre wavelengths |
EN ISO 527-4:1997 | Plastics - Determination of tensile properties - Part 4: Test conditions for isotropic and orthotopic fibre-reinforced plastic composites (ISO 527-4:1997) |
EN ISO 527-2:2012 | Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:2012) |
EN ISO 75-1:2013 | Plastics - Determination of temperature of deflection under load - Part 1: General test method (ISO 75-1:2013) |
ISO 8256:2004 | Plastics — Determination of tensile-impact strength |
ISO 10350:1993 | Plastics Acquisition and presentation of comparable single-point data |
EN ISO 2818:1996 | Plastics - Preparation of test specimens by machining (ISO 2818:1994) |
EN ISO 527-1:2012 | Plastics - Determination of tensile properties - Part 1: General principles (ISO 527-1:2012) |
ISO 75-2:2013 | Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite |
ISO 1628-3:2010 | Plastics — Determination of the viscosity of polymers in dilute solution using capillary viscometers — Part 3: Polyethylenes and polypropylenes |
ISO 527-2:2012 | Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics |
EN ISO 75-2:2013 | Plastics - Determination of temperature of deflection under load - Part 2: Plastics and ebonite (ISO 75-2:2013) |
ISO 1183:1987 | Plastics Methods for determining the density and relative density of non-cellular plastics |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN ISO 3167:2014 | Plastics - Multipurpose test specimens (ISO 3167:2014) |
IEC 60093:1980 | Methods of test for volume resistivity and surface resistivity of solid electrical insulating materials |
ISO 1210:1992 | Plastics — Determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source |
ISO 3146:2000 | Plastics — Determination of melting behaviour (melting temperature or melting range) of semi-crystalline polymers by capillary tube and polarizing-microscope methods |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
ISO 11542-1:2001 | Plastics Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materials Part 1: Designation system and basis for specifications |
ISO 291:2008 | Plastics Standard atmospheres for conditioning and testing |
ISO 179-1:2010 | Plastics — Determination of Charpy impact properties — Part 1: Non-instrumented impact test |
ISO 62:2008 | Plastics Determination of water absorption |
EN ISO 291:2008 | Plastics - Standard atmospheres for conditioning and testing (ISO 291:2008) |
ISO 4589-2:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 2: Ambient-temperature test |
ISO 2818:1994 | Plastics — Preparation of test specimens by machining |
ISO 899-1:2017 | Plastics — Determination of creep behaviour — Part 1: Tensile creep |
ISO 178:2010 | Plastics Determination of flexural properties |
ISO 4589-1:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 1: General requirements |
ISO 527-1:2012 | Plastics Determination of tensile properties Part 1: General principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.