ISO 13370:2017
Current
The latest, up-to-date edition.
Thermal performance of buildings — Heat transfer via the ground — Calculation methods
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
21-06-2017
ISO 13370:2017 provides methods of calculation of heat transfer coefficients and heat flow rates for building elements in thermal contact with the ground, including slab‐on‐ground floors, suspended floors and basements. It applies to building elements, or parts of them, below a horizontal plane in the bounding walls of the building situated
- at the level of the inside floor surface, for slab‐on‐ground floors, suspended floors and unheated basements;
NOTE 1 In some cases, external dimension systems define the boundary at the lower surface of the floor slab.
- at the level of the external ground surface, for heated basements.
ISO 13370:2017 includes calculation of the steady‐state part of the heat transfer (the annual average rate of heat flow) and the part due to annual periodic variations in temperature (the seasonal variations of the heat flow rate about the annual average). These seasonal variations are obtained on a monthly basis and, except for the application to dynamic simulation programmes in Annex D, ISO 13370:2017 does not apply to shorter periods of time.
NOTE 2 Table 1 in the Introduction shows the relative position of ISO 13370:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
DevelopmentNote |
Supersedes ISO/DIS 13370. (06/2017)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNI EN ISO 13370:2018 | Identical |
BS EN ISO 13370:2017 | Identical |
NEN EN ISO 13370 : 2017 | Identical |
DIN EN ISO 13370:2015-06 (Draft) | Identical |
PN EN ISO 13370 : 2017-09 | Identical |
UNE-EN ISO 13370:2010 | Identical |
DIN EN ISO 13370:2018-03 | Identical |
ONORM EN ISO 13370 : 2018 | Identical |
EN ISO 13370:2017 | Identical |
SS-EN ISO 13370:2017 | Identical |
NS EN ISO 13370 : 2017 | Identical |
I.S. EN ISO 13370:2007 | Identical |
I.S. EN ISO 13370:2017 | Identical |
UNE-EN ISO 13370:2017 | Identical |
SN EN ISO 13370 : 2017 | Identical |
PNE-EN ISO 13370 | Identical |
GOST R ISO 13370 : 2016 | Identical |
UNI EN ISO 13370 : 2008 | Identical |
NF EN ISO 13370 : 2017 | Identical |
PREN ISO 13791 : DRAFT 2010 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - GENERAL CRITERIA AND VALIDATION PROCEDURES |
15/30303583 DC : 0 | BS EN ISO 52018-1 - ENERGY PERFORMANCE OF BUILDINGS - INDICATORS FOR PARTIAL EPB REQUIREMENTS RELATED TO THERMAL ENERGY BALANCE AND FABRIC FEATURES - PART 1: OVERVIEW OF OPTIONS |
I.S. EN ISO 13792:2012 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS (ISO 13792:2012) |
10/30202116 DC : 0 | BS EN ISO 13791 - THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - GENERAL CRITERIA AND VALIDATION PROCEDURES |
I.S. EN ISO 13791:2012 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - GENERAL CRITERIA AND VALIDATION PROCEDURES (ISO 13791:2012) |
ISO 10211:2017 | Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations |
15/30303577 DC : 0 | BS EN ISO 52016-1 - ENERGY PERFORMANCE OF BUILDINGS - CALCULATION OF THE ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND HEATING AND COOLING LOAD IN A BUILDING OR BUILDING ZONE - PART 1: CALCULATION PROCEDURES |
15/30313355 DC : 0 | BS EN ISO 13789 - THERMAL PERFORMANCE OF BUILDINGS - TRANSMISSION AND VENTILATION HEAT TRANSFER COEFFICIENTS - CALCULATION METHOD |
DIN 4108 Beiblatt 2:2006-03 | THERMAL INSULATION AND ENERGY ECONOMY IN BUILDINGS - THERMAL BRIDGES - EXAMPLES FOR PLANNING AND PERFORMANCE |
DIN EN ISO 13788:2013-05 | Hygrothermal performance of building components and building elements - Internal surface temperature to avoid critical surface humidity and interstitial condensation - Calculation methods (ISO 13788:2012) |
PD CEN ISO/TR 52016-2:2017 | Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Explanation and justification of ISO 52016-1 and ISO 52017-1 |
05/30140625 DC : 0 | EN 15377-2 - HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 2: DESIGN, DIMENSIONING AND INSTALLATION |
BS EN 15316-2-1:2007 | Heating systems in buildings. Method for calculation of system energy requirements and system efficiencies Space heating emission systems |
I.S. EN ISO 14683:2017 | THERMAL BRIDGES IN BUILDING CONSTRUCTION - LINEAR THERMAL TRANSMITTANCE - SIMPLIFIED METHODS AND DEFAULT VALUES (ISO 14683:2017) |
I.S. EN 15377-1:2008 | HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 1: DETERMINATION OF THE DESIGN HEATING AND COOLING CAPACITY |
UNI EN 15377-2 : 2008 | HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 2: DESIGN, DIMENSIONING AND INSTALLATION |
EN ISO 10211:2017 | Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2017) |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
I.S. EN ISO 52000-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - OVERARCHING EPB ASSESSMENT - PART 1 - GENERAL FRAMEWORK AND PROCEDURES (ISO 52000-1:2017) |
I.S. EN ISO 10211:2017 | THERMAL BRIDGES IN BUILDING CONSTRUCTION - HEAT FLOWS AND SURFACE TEMPERATURES - DETAILED CALCULATIONS (ISO 10211:2017) |
EN ISO 52016-1:2017 | Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 1: Calculation procedures (ISO 52016-1:2017) |
UNE-EN ISO 6946:2012 | Building components and building elements - Thermal resistance and thermal transmittance - Calculation method (ISO 6946:2007) |
BS EN 12831:2003 | Heating systems in buildings. Method for calculation of the design heat load |
I.S. EN ISO 13788:2012 | HYGROTHERMAL PERFORMANCE OF BUILDING COMPONENTS AND BUILDING ELEMENTS - INTERNAL SURFACE TEMPERATURE TO AVOID CRITICAL SURFACE HUMIDITY AND INTERSTITIAL CONDENSATION - CALCULATION METHODS (ISO 13788:2012) |
DIN EN ISO 13792:2012-08 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS (ISO 13792:2012) |
EN 12831:2003 | Heating systems in buildings - Method for calculation of the design heat load |
EN 12831-1:2017 | Energy performance of buildings - Method for calculation of the design heat load - Part 1: Space heating load, Module M3-3 |
CEN ISO/TR 52016-2:2017 | Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 (ISO/TR 52016-2:2017) |
DIN EN 12831-1:2017-09 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD, MODULE M3-3 |
ISO 14683:2017 | Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values |
BS EN ISO 52016-1:2017 | Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Calculation procedures |
BS EN ISO 10211:2017 | Thermal bridges in building construction. Heat flows and surface temperatures. Detailed calculations |
BS EN ISO 13789:2017 | Thermal performance of buildings. Transmission and ventilation heat transfer coefficients. Calculation method |
15/30303580 DC : DRAFT JAN 2015 | BS EN ISO 52017-1 - ENERGY PERFORMANCE OF BUILDINGS - CALCULATION OF THE DYNAMIC THERMAL BALANCE IN A BUILDING OR BUILDING ZONE - PART 1: GENERIC CALCULATION PROCEDURE |
UNI EN 15377-1 : 2008 | HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 1: DETERMINATION OF THE DESIGN HEATING AND COOLING CAPACITY |
I.S. EN ISO 11855-2:2015 | BUILDING ENVIRONMENT DESIGN - DESIGN, DIMENSIONING, INSTALLATION AND CONTROL OF EMBEDDED RADIANT HEATING AND COOLING SYSTEMS - PART 2: DETERMINATION OF THE DESIGN HEATING AND COOLING CAPACITY (ISO 11855-2:2012) |
I.S. EN 12831-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD, MODULE M3-3 |
S.R. CEN ISO/TR 52019-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - HYGROTHERMAL PERFORMANCE OF BUILDING COMPONENTS AND BUILDING ELEMENTS - PART 2: EXPLANATION AND JUSTIFICATION (ISO/TR 52019-2:2017) |
PD CEN ISO/TR 52019-2:2017 | Energy performance of buildings. Hygrothermal performance of building components and building elements Explanation and justification |
ISO 13789:2017 | Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method |
EN ISO 52000-1:2017 | Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures (ISO 52000-1:2017) |
BS EN ISO 13792:2012 | Thermal performance of buildings. Calculation of internal temperatures of a room in summer without mechanical cooling. Simplified methods |
DIN EN ISO 13790:2008-09 | ENERGY PERFORMANCE OF BUILDINGS - CALCULATION OF ENERGY USE FOR SPACE HEATING AND COOLING |
DIN EN 15316-2-1:2007-10 | HEATING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 2-1: SPACE HEATING EMISSION SYSTEMS |
VDI 2078:2015-06 | Calculation of thermal loads and room temperatures (design cooling load and annual simulation) |
S.R. CEN ISO/TR 52016-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 2: EXPLANATION AND JUSTIFICATION OF ISO 52016-1 AND ISO 52017-1 (ISO/TR 52016-2:2017) |
BS EN 12831-1:2017 | Energy performance of buildings. Method for calculation of the design heat load Space heating load, Module M3-3 |
I.S. EN 15316-2-1:2007 | HEATING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 2-1: SPACE HEATING EMISSION SYSTEMS |
BS EN ISO 11855-2:2015 | Building environment design. Design, dimensioning, installation and control of embedded radiant heating and cooling systems Determination of the design heating and cooling capacity |
UNE-EN ISO 10211:2012 | Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2007) |
05/30134438 DC : DRAFT MAY 2005 | ISO 10211 - THERMAL BRIDGES IN BUILDING CONSTRUCTION - HEAT FLOWS AND SURFACE TEMPERATURES - DETAILED CALCULATIONS |
ISO 12575-1:2012 | Thermal insulation products — Exterior insulating systems for foundations — Part 1: Material specification |
ISO 52017-1:2017 | Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures |
I.S. EN 15377-2:2008 | HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 2: DESIGN, DIMENSIONING AND INSTALLATION |
PREN ISO 13792 : DRAFT 2010 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS |
ISO 52016-1:2017 | Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 1: Calculation procedures |
ISO/TR 52016-2:2017 | Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1 |
ONORM B 8110-3 : 2012 | THERMAL PROTECTION IN BUILDING CONSTRUCTION - PART 3: PREVENTION OF SUMMERLY OVERHEATING |
UNI EN ISO 13788 : 2013 | HYGROTHERMAL PERFORMANCE OF BUILDING COMPONENTS AND BUILDING ELEMENTS - INTERNAL SURFACE TEMPERATURE TO AVOID CRITICAL SURFACE HUMIDITY AND INTERSTITIAL CONDENSATION - CALCULATION METHODS |
UNI EN ISO 13792 : 2012 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS |
UNI EN 12831 : 2006 | HEATING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD |
UNI EN ISO 13790 : 2008 | ENERGY PERFORMANCE OF BUILDINGS - CALCULATION OF ENERGY USE FOR SPACE HEATING AND COOLING |
BS EN ISO 14683:2017 | Thermal bridges in building construction. Linear thermal transmittance. Simplified methods and default values |
BS EN 15377-2:2008 | Heating systems in buildings. Design of embedded water based surface heating and cooling systems Design, dimensioning and installation |
14/30309932 DC : 0 | BS EN 12831-1 - HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD |
15/30313349 DC : 0 | BS EN ISO 10211 - THERMAL BRIDGES IN BUILDING CONSTRUCTION - HEAT FLOWS AND SURFACE TEMPERATURES - DETAILED CALCULATIONS |
I.S. EN ISO 13790:2008 | ENERGY PERFORMANCE OF BUILDINGS - CALCULATION OF ENERGY USE FOR SPACE HEATING AND COOLING |
I.S. EN ISO 52017-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - SENSIBLE AND LATENT HEAT LOADS AND INTERNAL TEMPERATURES - PART 1: GENERIC CALCULATION PROCEDURES (ISO 52017-1:2017) |
UNE-EN ISO 13790:2011 | Energy performance of buildings - Calculation of energy use for space heating and cooling (ISO 13790:2008) |
BS ISO 12575-1:2012 | Thermal insulation. Exterior insulating systems for foundations Material specification |
UNE-EN ISO 13791:2013 | Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - General criteria and validation procedures (ISO 13791:2012) |
05/30134444 DC : DRAFT MAY 2005 | ISO/DIS 13789 - THERMAL PERFORMANCE OF BUILDINGS - TRANSMISSION AND VENTILATION HEAT TRANSFER COEFFICIENTS - CALCULATION METHOD |
EN ISO 11855-2:2015 | Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 2: Determination of the design heating and cooling capacity (ISO 11855-2:2012) |
BS EN ISO 13793:2001 | Thermal performance of buildings. Thermal design of foundations to avoid frost heave |
BS EN ISO 13788:2012 | Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods |
BS EN ISO 13791:2004 | Thermal performance of buildings. Calculation of internal temperatures of a room in summer without mechanical cooling. General criteria and validation procedures |
ISO 11855-2:2012 | Building environment design Design, dimensioning, installation and control of embedded radiant heating and cooling systems Part 2: Determination of the design heating and cooling capacity |
ISO 13788:2012 | Hygrothermal performance of building components and building elements — Internal surface temperature to avoid critical surface humidity and interstitial condensation — Calculation methods |
ISO 13791:2012 | Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling General criteria and validation procedures |
ISO 13790:2008 | Energy performance of buildings Calculation of energy use for space heating and cooling |
ISO/TR 52019-2:2017 | Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification |
UNE-EN ISO 13788:2016 | Hygrothermal performance of building components and building elements - Internal surface temperature to avoid critical surface humidity and interstitial condensation - Calculation methods (ISO 13788:2012, Corrected version 2020-05) |
EN 15377-2:2008 | Heating systems in buildings - Design of embedded water based surface heating and cooling systems - Part 2: Design, dimensioning and installation |
EN ISO 14683:2017 | Thermal bridges in building construction - Linear thermal transmittance - Simplified methods and default values (ISO 14683:2017) |
EN ISO 13792:2012 | Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods (ISO 13792:2012) |
EN ISO 13791:2012 | Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - General criteria and validation procedures (ISO 13791:2012) |
EN 15377-1:2008 | Heating systems in buildings - Design of embedded water based surface heating and cooling systems - Part 1: Determination of the design heating and cooling capacity |
EN ISO 13789:2017 | Thermal performance of buildings - Transmission and ventilation heat transfer coefficients - Calculation method (ISO 13789:2017) |
EN 15316-2-1:2007 | Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 2-1: Space heating emission systems |
EN ISO 13790:2008 | Energy performance of buildings - Calculation of energy use for space heating and cooling (ISO 13790:2008) |
EN ISO 13788:2012 | Hygrothermal performance of building components and building elements - Internal surface temperature to avoid critical surface humidity and interstitial condensation - Calculation methods (ISO 13788:2012, Corrected version 2020-05) |
UNE-EN ISO 13792:2013 | Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling - Simplified methods (ISO 13792:2012) |
BS EN ISO 52017-1:2017 | Energy performance of buildings. Sensible and latent heat loads and internal temperatures Generic calculation procedures |
10/30202119 DC : 0 | BS EN ISO 13792 - THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - SIMPLIFIED METHODS |
05/30134447 DC : DRAFT MAY 2005 | ISO/DIS 14683 - THERMAL BRIDGES IN BUILDING CONSTRUCTION - LINEAR THERMAL TRANSMITTANCE - SIMPLIFIED METHODS AND DEFAULT VALUES |
I.S. EN ISO 13789:2017 | THERMAL PERFORMANCE OF BUILDINGS - TRANSMISSION AND VENTILATION HEAT TRANSFER COEFFICIENTS - CALCULATION METHOD (ISO 13789:2017) |
I.S. EN ISO 52016-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 1: CALCULATION PROCEDURES (ISO 52016-1:2017) |
UNE-EN ISO 11855-2:2016 | Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 2: Determination of the design heating and cooling capacity (ISO 11855-2:2012) |
EN ISO 52017-1:2017 | Energy performance of buildings - Sensible and latent heat loads and internal temperatures - Part 1: Generic calculation procedures (ISO 52017-1:2017) |
ISO 13792:2012 | Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling Simplified methods |
BS EN ISO 13790:2008 | Energy performance of buildings. Calculation of energy use for space heating and cooling |
CEN ISO/TR 52019-2:2017 | Energy performance of buildings - Hygrothermal performance of building components and building elements - Part 2: Explanation and justification (ISO/TR 52019-2:2017) |
DIN EN ISO 13793:2001-06 | THERMAL PERFORMANCE OF BUILDINGS - THERMAL DESIGN OF FOUNDATIONS TO AVOID FROST HEAVE |
DIN EN 15377-1:2009-02 | HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 1: DETERMINATION OF THE DESIGN HEATING AND COOLING CAPACITY |
DIN EN 15377-2:2008-11 | HEATING SYSTEMS IN BUILDINGS - DESIGN OF EMBEDDED WATER BASED SURFACE HEATING AND COOLING SYSTEMS - PART 2: DESIGN, DIMENSIONING AND INSTALLATION |
DIN EN ISO 13791:2012-08 | THERMAL PERFORMANCE OF BUILDINGS - CALCULATION OF INTERNAL TEMPERATURES OF A ROOM IN SUMMER WITHOUT MECHANICAL COOLING - GENERAL CRITERIA AND VALIDATION PROCEDURES (ISO 13791:2012) |
ISO 13789:2017 | Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method |
CEN/TS 16629:2014 | Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards |
ISO 10211:2017 | Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations |
CEN/TS 16628:2014 | Energy Performance of Buildings - Basic Principles for the set of EPB standards |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
ISO/TR 52019-2:2017 | Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
ISO/TR 52000-2:2017 | Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1 |
ISO 6946:2017 | Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
ISO 14683:2017 | Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.