ISO 22201:2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Lifts (elevators) Design and development of programmable electronic systems in safety-related applications for lifts (PESSRAL)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
14-03-2019
05-01-2009
ISO 22201:2009 is applicable to the product family of passenger and goods/passenger lifts used in residential buildings, offices, hospitals, hotels, industrial plants, etc. ISO 22201:2009 covers those aspects that it is necessary to address when programmable electronic systems are used to carry out electric safety functions for lifts (PESSRAL). ISO 22201:2009 is applicable for lift-safety functions that are identified in lift codes, standards or laws that reference ISO 22201:2009 for PESSRAL. The SILs specified in ISO 22201:2009 are understood to be valid for PESSRAL in the context of the referenced lift codes, standards and laws.
ISO 22201:2009 is also applicable for PESSRAL that are new or deviate from those described in ISO 22201:2009.
The requirements of ISO 22201:2009 regarding electrical safety/protective devices are such that it is not necessary to take into consideration the possibility of a failure of an electric safety/protective device complying with all the requirements of the standard.
ISO 22201:2009 does not cover hazards arising from the PES equipment itself, such as electric shock etc.; the concept of fail-safe, which can be of value when the failure modes are well defined and the level of complexity is relatively low; the concept of fail-safe is considered inappropriate because of the full range of complexity of the PESSRAL that are within the scope of ISO 22201:2009; and other relevant requirements necessary for the complete application of a PESSRAL in a lift-safety function, such as the mechanical construction, mounting and labelling of switches, actuators, or sensors that contain the PESSRAL. It is necessary that these requirements be carried out in accordance with the national lift standard that references ISO 22201:2009.
DevelopmentNote |
Supersedes ISO/DIS 22201. (01/2009)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
BS ISO 22201:2009 | Identical |
BS EN IEC 62246-1-1:2018 | Reed switches Generic specification. Blank detail specification |
17/30336631 DC : 0 | BS EN 62246-1-1 - REED SWITCHES - PART 1-1: DETAIL SPECIFICATION - QUALITY ASSESSMENT |
ISO/TS 22559-2:2010 | Safety requirements for lifts (elevators) Part 2: Safety parameters meeting the global essential safety requirements (GESRs) |
EN IEC 62246-1-1:2018 | Reed switches - Part 1-1: Generic specification - Blank detail specification |
I.S. EN IEC 62246-1-1:2018 | REED SWITCHES - PART 1-1: GENERIC SPECIFICATION - BLANK DETAIL SPECIFICATION |
DD ISO/TS 22559-2:2010 | Safety requirements for lifts (elevators) Safety parameters meeting the global essential safety requirements (GESRs) |
ISO/IEC TR 10000-1:1998 | Information technology — Framework and taxonomy of International Standardized Profiles — Part 1: General principles and documentation framework |
ISO 10241:1992 | International terminology standards Preparation and layout |
ISO 690:2010 | Information and documentation Guidelines for bibliographic references and citations to information resources |
IEC 61249-2-1:2005 | Materials for printed boards and other interconnecting structures - Part 2-1: Reinforced base materials, clad and unclad - Phenolic cellulose paper reinforced laminated sheets, economic grade, copper clad |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 62326-1:2002 | Printed boards - Part 1: Generic specification |
ASME A17.1-2016/CSA B44-16 | Safety code for elevators and escalators (Bi-national standard, with ASME A17.1) |
IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
ISO 22200:2009 | Electromagnetic compatibility Product family standard for lifts, escalators and moving walks Immunity |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
ASME A17.1 : 2016 | SAFETY CODE FOR ELEVATORS AND ESCALATORS - INCLUDES REQUIREMENTS FOR ELEVATORS, ESCALATORS, DUMBWAITERS, MOVING WALKS, MATERIAL LIFTS, AND DUMBWAITERS WITH AUTOMATIC TRANSFER DEVICES |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.