ISO 6980-1:2006
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Nuclear energy — Reference beta-particle radiation — Part 1: Methods of production
Hardcopy , PDF
English, French
07-08-2006
09-04-2025
ISO 6980-1:2006 specifies the requirements for reference beta radiation fields produced by radionuclide sources to be used for the calibration of personal and area dosimeters and dose-rate meters to be used for the determination of the quantities Hp(0,07) and H'(0,07), and for the determination of their response as a function of beta particle energy and angle of incidence. It gives the characteristics of radionuclides that have been used to produce reference beta radiation fields, gives examples of suitable source constructions and describes methods for the measurement of the residual maximum beta particle energy and the dose equivalent rate at a depth of 0,07 mm in the International Commission on Radiation Units and Measurements (ICRU) sphere. The energy range involved lies between 66 keV) and 3,6 MeV and the dose equivalent rates are in the range from about 10-5Sv h-1 to at least 10 Sv h-1. In addition, for some sources variations of the dose equivalent rate as a function of the angle of incidence are given.
ISO 6980-1:2006 proposes two series of beta reference radiation fields from which the radiation necessary for determining the characteristics (calibration and energy and angular dependence of response) of an instrument can be selected.
Series 1 reference radiation fields are produced by radionuclide sources used with beam flattening filters designed to give uniform dose equivalent rates over a large area at a specified distance. The proposed sources of 90Sr + 90Y, 85Kr, 204Tl and 147Pm produce maximum dose equivalent rates of approximately 200 mSv h-1.
Series 2 reference radiation fields are produced without the use of beam-flattening filters, which allows large area planar sources and a range of source-to-calibration plane distances to be used. Close to the sources, only relatively small areas of uniform dose rate are produced but this series has the advantage of extending the energy and dose rate ranges beyond those of series 1. The radionuclides used are those of series 1 with the addition of the radionuclides 14C and 106Ru + 106Rh; these sources produce dose equivalent rates of up to 10 Sv h-1.
| Committee |
ISO/TC 85/SC 2
|
| DevelopmentNote |
Supersedes ISO/DIS 6980-1 (08/2006) Together with ISO 6980-2 and ISO 6980-3, supersedes ISO 6980 (09/2006)
|
| DocumentType |
Standard
|
| Pages |
13
|
| ProductNote |
This standard is also refers to ICRP 60:1991,ICRU 56:1997,ICRU 44:1989,ICRU 31:1979,ICRU 37:1984,ICRU 39:1985,
|
| PublisherName |
International Organization for Standardization
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| IS 17994 : Part 1 : 2022 | Identical |
| NF ISO 6980-1 : 2006 | Identical |
| BS ISO 6980-1:2006 | Identical |
A newer version of this standard is available.