Human response to vibration — Measuring instrumentation — Part 1: General purpose vibration meters
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
French, English
03-05-2017
ISO 8041-1:2017 specifies the performance specifications and tolerance limits for instruments designed to measure vibration values, for the purpose of assessing human response to vibration. It includes requirements for pattern evaluation, or validation, periodic verification and in situ checks, and the specification of vibration calibrators for in situ checks.
Vibration instruments specified in this document can be single instruments, combinations of instrumentation or computer-based acquisition and analysis systems.
Vibration instruments specified in this document are intended to measure vibration for one or more applications, such as the following:
- hand-transmitted vibration (see ISO 5349‑1);
- whole-body vibration (see ISO 2631‑1, ISO 2631‑2 and ISO 2631‑4);
- low-frequency whole-body vibration in the frequency range from 0,1 Hz to 0,5 Hz (see ISO 2631‑1).
Vibration instruments can be designed for measurement according to one or more of the frequency weightings defined within each of these applications.
Three levels of performance testing are defined in this document:
a) pattern evaluation or validation:
- pattern evaluation, i.e. a full test of the instrument against the specifications defined in this document;
- validation of one-off instruments, i.e. a limited set of tests of an individual vibration measuring system against the relevant specifications defined in this document;
b) periodic verification, i.e. an intermediate set of tests designed to ensure that an instrument remains within the required performance specification;
c) in situ checks, i.e. a minimum level of testing required to indicate that an instrument is likely to be functioning within the required performance specification.
DevelopmentNote |
Supersedes ISO/FDIS 8041-1 and ISO 8041. (05/2017)
|
DocumentType |
Standard
|
Pages |
110
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN ISO 8041-1:2017-10 | Identical |
NF EN ISO 8041-1 : 2017 | Identical |
NEN EN ISO 8041-1 : 2017 | Identical |
NS EN ISO 8041-1 : 2017 | Identical |
I.S. EN ISO 8041-1:2017 | Identical |
PN EN ISO 8041-1 : 2017 | Identical |
UNI EN ISO 8041-1 : 2017 | Identical |
UNE-EN ISO 8041-1:2018 | Identical |
BS EN ISO 8041-1:2017 | Identical |
EN ISO 8041-1:2017 | Identical |
SN EN ISO 8041-1:2017 | Identical |
BS PD ISO/TR 19664 : 2017 | HUMAN RESPONSE TO VIBRATION - GUIDANCE AND TERMINOLOGY FOR INSTRUMENTATION AND EQUIPMENT FOR THE ASSESSMENT OF DAILY VIBRATION EXPOSURE AT THE WORKPLACE ACCORDING TO THE REQUIREMENTS OF HEALTH AND SAFETY |
PD ISO/TR 18570:2017 | Mechanical vibration. Measurement and evaluation of human exposure to hand transmitted vibration. Supplementary method for assessing risk of vascular disorders |
ISO/TR 18570:2017 | Mechanical vibration Measurement and evaluation of human exposure to hand transmitted vibration Supplementary method for assessing risk of vascular disorders |
ISO/TR 19664:2017 | Human response to vibration Guidance and terminology for instrumentation and equipment for the assessment of daily vibration exposure at the workplace according to the requirements of health and safety |
ISO/TS 14837-31:2017 | Mechanical vibration — Ground-borne noise and vibration arising from rail systems — Part 31: Guideline on field measurements for the evaluation of human exposure in buildings |
ISO/TR 19664:2017 | Human response to vibration Guidance and terminology for instrumentation and equipment for the assessment of daily vibration exposure at the workplace according to the requirements of health and safety |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
ISO 10326-1:2016 | Mechanical vibration Laboratory method for evaluating vehicle seat vibration Part 1: Basic requirements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
ISO 2631-4:2001 | Mechanical vibration and shock — Evaluation of human exposure to whole-body vibration — Part 4: Guidelines for the evaluation of the effects of vibration and rotational motion on passenger and crew comfort in fixed-guideway transport systems |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO 2041:2009 | Mechanical vibration, shock and condition monitoring Vocabulary |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
DIN 45662:1996-12 | VIBRATION MEASURING INSTRUMENTATION - FUNDAMENTAL REQUIREMENTS AND VERIFICATION |
ISO 1683:2015 | Acoustics Preferred reference values for acoustical and vibratory levels |
ISO 2631-2:2003 | Mechanical vibration and shock — Evaluation of human exposure to whole-body vibration — Part 2: Vibration in buildings (1 Hz to 80 Hz) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
ISO 2631-1:1997 | Mechanical vibration and shock — Evaluation of human exposure to whole-body vibration — Part 1: General requirements |
ISO 5348:1998 | Mechanical vibration and shock Mechanical mounting of accelerometers |
ISO 5349-1:2001 | Mechanical vibration Measurement and evaluation of human exposure to hand-transmitted vibration Part 1: General requirements |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 5805:1997 | Mechanical vibration and shock — Human exposure — Vocabulary |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.