ISO/TR 5660-3:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 3: Guidance on measurement
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
14-03-2019
English
25-11-2003
Foreword
Introduction
1 Scope
2 Normative references
3 Capability and limitations of the cone calorimeter
4 Calibration of the cone calorimeter
5 Test specimen preparation and presentation
6 Selection of heat flux
7 Ignition protocols
8 Guidance on the testing of non-standard products
9 Composites and layered products
10 Liquids
11 The theory of oxygen consumption calorimetry
12 Start and end of test
13 Recommendations for presentation of data
Annex A (normative) Effect of additives and fillers
Bibliography
ISO/TR 5660-3:2003 examines the limitations of the cone calorimeter as currently used for building products and recommends ways in which some of these may be overcome for other types of products for other application areas. It compiles information from a large body of experience with regard to the use of the instrument into a set of guidelines which will help to standardize the use of the cone calorimeter in this wider scope.
Particular guidance is given on aspects of specimen preparation and on the behaviour, such as melting, spalling and intumescing, of specimens exposed to radiant heat. The relevance of specimen thickness and the use of substrate, and methods of fixing to substrate, are also discussed. Advice is given on approaches to testing a variety of "non standard" products. Recommendations are made on techniques of calibration of the apparatus, selection of appropriate heat flux levels and ignition protocols.
In addition to the guidance given to operators, ISO/TR 5660-3:2003 makes recommendations on presentation of the test results.
DocumentType |
Technical Report
|
Pages |
33
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
12/30211334 DC : 0 | BS ISO 15791-1 - PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO/DIS 15791-1:2012) |
DD IEC/TS 60695-8-3:2008 | Fire hazard testing Heat release. Heat release of insulating liquids used in electrotechnical products |
DD ISO/TS 14934-4:2007 | Fire tests. Calibration of heat flux meters Guidance on the use of heat flux meters in fire tests |
UNI EN ISO 25762 : 2012 | PLASTICS - GUIDANCE ON THE ASSESSMENT OF THE FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED POLYMER COMPOSITES |
BS EN ISO 25762:2012 | Plastics. Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites |
DIN EN ISO 25762:2012-04 | Plastics - Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites (ISO 25762:2009) |
BS ISO 10840:2008 | Plastics. Guidance for the use of standard fire tests |
ISO 10840:2008 | Plastics — Guidance for the use of standard fire tests |
CEI 89-37 : 2014 | FIRE HAZARD TESTING - PART 8-3: HEAT RELEASE - HEAT RELEASE OF INSULATING LIQUIDS USED IN ELECTROTECHNICAL PRODUCTS |
ISO/TS 14934-4:2007 | Fire tests Calibration of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests |
IEC TS 60695-8-3:2008 | Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products |
08/30192184 DC : 0 | ISO 15928-4 - HOUSES - DESCRIPTION OF PERFORMANCE - PART 4: FIRE SAFETY |
ISO/TR 17252:2008 | Fire tests Applicability of reaction to fire tests to fire modelling and fire safety engineering |
I.S. EN ISO 25762:2012 | PLASTICS - GUIDANCE ON THE ASSESSMENT OF THE FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED POLYMER COMPOSITES (ISO 25762:2009) |
ISO 25762:2009 | Plastics Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites |
EN ISO 25762:2012 | Plastics - Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites (ISO 25762:2009) |
08/30154274 DC : DRAFT MAR 2008 | BS ISO 25762 - PLASTICS - GUIDANCE ON THE ASSESSMENT OF FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED COMPOSITES |
BS ISO 25762 : 2009 | PLASTICS - GUIDANCE ON THE ASSESSMENT OF THE FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF FIBRE-REINFORCED POLYMER COMPOSITES |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO/TR 9122-1:1989 | Toxicity testing of fire effluents Part 1: General |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
ISO 5660-2:2002 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement) |
NFPA 264A : 1994 | STANDARD METHOD OF TEST FOR HEAT RELEASE RATES FOR UPHOLSTERED FURNITURE COMPONENTS OR COMPOSITES AND MATTRESSES USING AN OXYGEN CONSUMPTION CALOMETER |
ISO/TS 14934-1:2002 | Fire tests Calibration and use of radiometers and heat flux meters Part 1: General principles |
ISO/TR 3814:1989 | Tests for measuring "reaction-to-fire" of building materials — Their development and application |
ISO 17554:2014 | Reaction to fire tests Mass loss measurement |
ASTM E 1474 : 2014 : REDLINE | Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter |
ISO 554:1976 | Standard atmospheres for conditioning and/or testing — Specifications |
ISO/TR 14697:1997 | Fire tests — Guidance on the choice of substrates for building products |
ISO 13927:2015 | Plastics — Simple heat release test using a conical radiant heater and a thermopile detector |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
ISO 11907-4:1998 | Plastics — Smoke generation — Determination of the corrosivity of fire effluents — Part 4: Dynamic decomposition method using a conical radiant heater |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.