Section 1 INTRODUCTION
1.1 Scope
1.2 Roof Design Synthesis
1.3 Roof-Mounted Equipment
1.4 Climatic Conditions
1.5 Roofing Material Selection
Section 2 STRUCTURAL DECK
2.1 Functions
2.2 Design Factors
2.3 Precautions for Specific Roof Decks
Section 3 THERMAL INSULATION
3.1 Purposes for Insulation
3.2 Design Factors
3.3 Materials
3.4 Tapered Insulation
3.5 Application Criteria
Section 4 VAPOR CONTROL
4.1 Psychrometrics
4.2 Vapor Control Methods
Section 5 BITUMINOUS BUILT-UP ROOF MEMBRANE
5.1 Material Description
5.2 General Requirements
5.3 Membrane Design Recommendations
Section 6 SINGLE-PLY ROOFING SYSTEMS
6.1 Single-Ply Roofing Description
6.2 Perimeter Anchorage
6.3 Design Requirements/Considerations
6.4 Applicable Details
6.5 Single-Ply Membrane Standards
Section 7 SPRAYED POLYURETHANE FOAM
7.1 Material Description
7.2 Uses
7.3 Design Recommendations
7.4 Application Considerations
7.5 Flashings
7.6 Applicable Details
Section 8 PROTECTED MEMBRANE ROOF SYSTEM
8.1 Description
8.2 General Design Recommendations
8.3 Specific Design Recommendations
8.4 Variations
8.5 Other Considerations
8.6 Applicable Details
Section 9 STEEP ROOFING
9.1 Steep Roofing Description
9.2 Materials
9.3 General Design Requirements
9.4 Underlayments
9.5 Ventilation
9.6 Anchorage Techniques
9.7 Flashings
9.8 Applicable Details
Section 10 REROOFING
10.1 Introduction
10.2 Reroofing
10.3 Premature Failure Preliminary Investigation
10.4 Design Considerations
Section 11 FIRE RESISTANCE
11.1 General
11.2 External Fire Resistance
11.3 Internal Fire Hazards
11.4 Time-Temperature Ratings
11.5 Design Requirements
Section 12 WIND-UPLIFT RESISTANCE
12.1 Wind-Uplift Hazards
12.2 Failure
12.3 Ballasted Systems
12.4 Dead Load
12.5 Mechanical Fasteners
12.6 Design Data
Section 13 BELOW-GRADE WATERPROOFING
13.1 System Description
13.2 Uses
13.3 Precautions
13.4 Design Requirements
13.5 Dampproofing
13.6 Applicable Details
Section 14 PLAZA WATERPROOFING
14.1 System Description
14.2 Planters
14.3 General Requirements
14.4 Applicable Details
TABLES
BIBLIOGRAPHY
REFERENCES
GLOSSARY
Describes the guidelines for design of roofing, LAYOUT 1 and waterproofing systems for building construction.
Committee |
AREA FACR
|
DevelopmentNote |
A NOTICE 1 - Notice of Cancellation/Superseded by MIL STD 3007. (09/2005)
|
DocumentType |
Standard
|
Pages |
94
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Superseded
|
SupersededBy |
MIL HDBK 1028/8 : A | DESIGN OF PEST MANAGEMENT FACILITIES |
MIL-HDBK-1024-1 Base Document:1994 | AVIATION OPERATIONAL AND SUPPORT FACILITIES |
ASTM C 898 : 2001 | Standard Guide for Use of High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane With Separate Wearing Course |
ASTM E 108 : 2017 : REDLINE | Standard Test Methods for Fire Tests of Roof Coverings |
MIL-HDBK-1002-2 Revision A:1996 | LOADS |
ASTM D 4897 : 2001 | Standard Specification for Asphalt-Coated Glass-Fiber Venting Base Sheet Used in Roofing |
MIL-HDBK-1008 Revision C:1997 | FIRE PROTECTION FOR FACILITIES ENGINEERING, DESIGN, AND CONSTRUCTION |
UL 263:14ED 2011-06-21 | Fire Tests of Building Construction and Materials |
ASTM C 726 : 2017 : REDLINE | Standard Specification for Mineral Wool Roof Insulation Board |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.