• MIL HDBK 1028/3 : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MAINTENANCE FACILITIES FOR AMMUNITION, EXPLOSIVES AND TOXINS

    Available format(s):  PDF

    Superseded date:  12-11-2004

    Language(s): 

    Published date: 

    Publisher:  US Military Specs/Standards/Handbooks

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Section 1 INTRODUCTION
            1.1 Scope
            1.2 Cancellation
            1.3 General Structural Requirements
            1.4 Energy Conservation
            1.5 Building Protection
            1.6 Loading Dock Ramp Protection
            1.7 Fire Protection
            1.8 Radio Frequency Interference (RFI) Protection
            1.9 Security
            1.10 Safety
            1.11 Design Review Requirements
    Section 2 GENERAL AMMUNITION MAINTENANCE SHOPS
            2.1 Function
            2.2 Architectural and Structural Requirements
            2.3 Mechanical Requirements
            2.4 Electrical Requirements
            2.5 Explosion-Proof Weight-Handling Equipment
    Section 3 BOMB-TYPE AMMUNITION MAINTENANCE SHOPS
            3.1 Function
            3.2 Architectural and Structural Requirements
            3.3 Mechanical Requirements
            3.4 Electrical Requirements
            3.5 Explosion-Proof Weight-Handling Equipment
    Section 4 PROPELLANT POWDER MAINTENANCE SHOPS
            4.1 Function
            4.2 Architectural and Structural Requirements
            4.3 Mechanical Requirements
            4.4 Electrical Requirements
    Section 5 AIR/UNDERWATER WEAPONS SHOPS
            5.1 Function and Scope
            5.2 Location
            5.3 Architectural and Structural Requirements
            5.4 Mechanical Requirements
            5.5 Otto II Fuel Requirements
            5.6 Electrical Requirements
            5.7 Security
            5.8 Explosion-Proof Weight-Handling Equipment
    Section 6 QUALITY EVALUATION LABORATORY
            6.1 Function
            6.2 Location
            6.3 Layout
            6.4 Architectural and Structural Requirements
            6.5 Mechanical Requirements
            6.6 Electrical Requirements
    FACILITY PLATES
    REFERENCES

    Abstract - (Show below) - (Hide below)

    Presents criteria for ammunition, explosives, and toxins maintenance facilities at naval shore activities.

    General Product Information - (Show below) - (Hide below)

    Committee FACR 5037
    Development Note NOTICE 1 - Notice of Cancellation/Superseded by MIL STD 3007 (11/2004)
    Document Type Standard
    Publisher US Military Specs/Standards/Handbooks
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    NFPA 91 : 2015 EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS
    MIL-STD-704 Revision F:2004 AIRCRAFT ELECTRIC POWER CHARACTERISTICS
    MIL HDBK 1190 : 0 FACILITY PLANNING AND DESIGN GUIDE
    NFPA 33 : 2016 SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS
    MIL P 24441 : B PAINT, EPOXY POLYAMIDE, GENERAL SPECIFICATION FOR
    MIL-HDBK-1006-1 Revision A:1995 POLICY AND PROCEDURES FOR PROJECT DRAWING AND SPECIFICATION PREPARATION
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    MIL-HDBK-1013-1 Revision A:1993 DESIGN GUIDELINES FOR PHYSICAL SECURITY OF FIXED LAND-BASED FACILITIES
    MIL-HDBK-1008 Revision C:1997 FIRE PROTECTION FOR FACILITIES ENGINEERING, DESIGN, AND CONSTRUCTION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective