RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
07-10-2021
12-01-2013
Avant-propos
Introduction
1 Domaine d'application
2 Références normatives
3 Câbles monoconducteurs
4 Essais
Annexe A (informative) Guide précisant les modalités de
sélection des câbles destinés à
l'approbation de type
Annexe B (informative) Bibliographie
Tableau 1 - Prescriptions relatives à la constitution
Tableau 2 - Prescriptions d'essai
Tableau 3 - Prescriptions d'essai de souplesse
Tableau 4 - Classification des essais
Gives requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm[2] to 2,5 mm[2] single core).
DevelopmentNote |
PR NF EN 50306-2 December 2001. Indice de Classement: F63-306-2. (02/2002) Supersedes NFF 63 808. (07/2009)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
BS EN 50306-2:2002 | Identical |
DIN EN 50306-2 : 2003 | Identical |
NEN EN 50306-2 : 2002 | Identical |
I.S. EN 50306-2:2002 | Identical |
EN 50306-2:2002 | Identical |
NBN EN 50306-2 : 2003 | Identical |
NF EN 50306-4 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED |
NF EN 50306-3 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED |
NF EN 50306-1 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS |
NF EN 50306-1 : 2003 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS |
NF EN 50305 : 2002 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - TEST METHODS |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
NF EN 50267-2-2 : 2000 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST ON GAS EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 2-2: PROCEDURES - DETERMINATION OF DEGREE OF ACIDITY OF GASES FOR MATERIALS BY MEASURING PH AND CONDUCTIVITY |
NF EN 50334 : 2001 | MARKING BY INSCRIPTION FOR THE IDENTIFICATION OF CORES OF ELECTRIC CABLES |
NF EN 45545-1 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
NF EN 50267-2-1 : 2000 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST ON GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 2-1: PROCEDURES - DETERMINATION OF THE AMOUNT OF HALOGEN ACID GAS |
NF EN 60684-2 : 2012 | FLEXIBLE INSULATING SLEEVING - PART 2: METHODS OF TEST |
NF EN 50265-2-1 : 1999 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME |
NF EN 10002-1 : 2001 | METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
IEC 60811-2-1:1998+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests |
NF EN 50268-2 : 2000 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: PROCEDURE |
NF EN 60811-2-1 : 99 AMD 1 2002 | INSULATING AND SHEETING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS |
NF EN 60811 1-4 : 96 AMD 2 2002 | INSULATING AND SHEETING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 4: TEST AT LOW TEMPERATURE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.