NF EN 60664-5 : 2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 5: COMPREHENSIVE METHOD FOR DETERMINING CLEARANCES AND CREEPAGE DISTANCES EQUAL TO OR LESS THAN 2 MM
13-06-2015
12-01-2013
AVANT-PROPOS
INTRODUCTION
1 Domaine d'application et objet
2 Références normatives
3 Termes et définitions
4 Principes essentiels du dimensionnement des distances
d'isolement et des lignes de fuite
4.1 Remarques préliminaires
4.2 Principes de base
4.3 Tensions et caractéristiques assignées de tension
4.4 Fréquence
4.5 Durée d'application de la contrainte de tension
4.6 Pollution
4.7 Informations fournies avec le matériel
4.8 Matériau isolant
5 Exigences et procédures de dimensionnement
5.1 Généralités
5.2 Dimensionnement des distances d'isolement
5.3 Dimensionnement des lignes de fuite
5.4 Exigences pour l'isolation solide
6 Essais et mesures
6.1 Essais
6.2 Mesure des lignes de fuite et des distances d'isolement
Annexe A (informative) Dimensionnement pour maintenir la
résistance d'isolement minimale
Annexe B (normative) Essai d'adsorption d'eau
Annexe C (informative) Schémas de dimensionnement
Annexe D (informative) Essai de tension de tenue pour ligne
de fuite dans des conditions humides
Annexe ZA (normative) Références normatives à d'autres
publications internationales avec les publications
européennes correspondantes
Bibliographie
Describes the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearance and the creepage distance are identical and are along the surface of solid insulation.
DevelopmentNote |
Indice de classement: C20-040-5. PR NF EN 60664-5 December 2001. (01/2002) PR NF EN 60664-5 September 2006. (09/2006)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DIN EN 60664-5 : 2008 | Identical |
UNE-EN 60664-5:2008 | Identical |
EN 60664-5:2007 | Identical |
SN EN 60664-5 : 2003 | Identical |
I.S. EN 60664-5:2007 | Identical |
BS EN 60664-5:2003 | Identical |
IEC 60664-5:2007 | Identical |
NBN EN 60664-5 : 2008 | Identical |
NF EN 60664-1 : 2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
NF EN 60664-4 : 2006 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS |
NF EN 60721 3-9 : 93 AMD 1 95 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 9: MICROCLIMATES INSIDE PRODUCTS |
IEC 60721-3-9:1993 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 9: Microclimates inside products |
NF EN 60721 3-7 : 95 AMD 1 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 7: PORTABLE AND NON-STATIONARY USE |
NF EN 60664-1 : 2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
NF EN 60721 3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 3: STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.