• Shopping Cart
    There are no items in your cart

NF EN 60931-1 : 97 AMD 1 2003

Current

Current

The latest, up-to-date edition.

SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION

Published date

12-01-2013

Sorry this product is not available in your region.

SECTION 1: GÉNÉRALITÉS
1 Domaine d'application et objet
2 Références normatives
3 Définitions
4 Conditions de service
SECTION 2: PRESCRIPTIONS DE QUALITÉ DE QUALITÉ ET ESSAIS
5 Prescriptions relatives aux essais
6 Classification des essais
7 Mesure de la capacité et calcul de la puissance
8 Mesure de la tangente de l'angle de pertes (tan d) du
   condensateur
9 Essais diélectriques entre bornes
10 Essais diélectriques entre bornes et cuve
11 Essai du dispositif interne de décharge
12 Essai d'étanchéité
13 Essai de stabilité thermique
14 Mesure de la tangente de l'angle de pertes (tan d) du
   condensateur à température élevée
15 Essai diélectrique en choc de foudre entre bornes et cuve
16 Essai de décharge
17 Essai de vieillissement
18 Essai d'autorégénération
19 Essai de destructeur
SECTION 3: SURCHARGES
20 Tension maximale admissible
21 Courant maximal admissible
SECTION 4: REGLES DE SÉCURITÉ
22 Dispositif de décharge
23 Connexions à l'enveloppe
24 Protection de l'environnement
25 Autres règles de sécurité
26 Marquage du condensateur unitaire
27 Marquage des batteries
SECTION 6: GUIDE D'INSTALLATION ET D'EXPLOITATION
28 Généralités
29 Choix de la tension assignée
30 Température de service
31 Conditions spéciales de service
32 Surtensions
33 Courants de surcharge
34 Appareils de coupure et de protection et raccordement
35 Choix des lignes de fuite
36 Condensateurs raccordés à des réseaux pourvus de télécommande
   à fréquence acoustique
37 Compatibilité électromagnétique (CEM)
Annexes
A - Définitions, prescriptions et essais supplémentaires
    concernant les condensateurs de puissance pour filtrage en
    courants forts
B - Formules pour les condensateurs et les installations
ZA (normative) - Autres publications internationales citées dans
                 la présente norme avec les références des
                 publications européennes correspondantes

Applies to capacitor units and capacitor banks meant to be used, particularly, for power factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequency 15 Hz to 60 Hz. Coverage includes: voltage tests between terminals and container; maximum permissible voltage; protection of the environment; capacitors connected to systems with audiofrequency remote control.

DevelopmentNote
Indice de Classement: C54-118 (05/2003)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

NF EN 60831-1 : 2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
NF EN 61921 : 2003 POWER CAPACITORS - LOW VOLTAGE POWER FACTOR CORRECTION BANKS

IEC 60252:1993 A.C. motor capacitors
NFC 01 436 : 1990 ELECTROTECHNICAL VOCABULARY - CHAPTER 436: POWER CAPACITORS
IEC 60931-2:1995 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 2: Ageing test and destruction test
ENV 61000-2-2 : 1993 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61048:2006+AMD1:2015 CSV Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements
NF EN 60931-2 : 1996 SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 2: AGEING TEST AND DESTRUCTION TEST
NF EN 61049 : 1993 CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - PERFORMANCE REQUIREMENTS
HD 597 S1:1992/corrigendum:1992 COUPLING CAPACITORS AND CAPACITOR DIVIDERS
NF EN 60831-1 : 2014 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION
NFC 41 101 : 1995 HIGH VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
NFC 54 120 : 1980 CAPACITORS FOR INDUCTIVE HEAT GENERATING PLANTS OPERATING AT FREQUENCIES BETWEEN 40HZ AND 24000HZ - REQUIREMENTS
IEC 61071-1:1991 Power electronic capacitors - Part 1: General
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
NF EN 60269-1 : 2007 AMD 2 2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
HD 207 : 200S1 RECOMMENDATION FOR CAPACITORS FOR INDUCTIVE HEAT GENERATING PLANTS OPERATING AT FREQUENCIES BETWEEN 40 AND 24 000 HZ
IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
NF EN 61048 : 2006 AMD 1 2016 AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS
NF EN 61071-1 : 1997 POWER ELECTRONIC CAPACITORS - PART 1: GENERAL
IEC 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General
NF EN 61000-4-1 : 2007
IEC 60143:1972 Series capacitors for power systems
NF EN 60252 : 1994
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
NF EN 60931-3 : 1997 SHUNT POWER CAPACITORS OF THE NON-SELF HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV
IEC 60831-1:2014 RLV Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation
IEC 60931-3:1996 Shunt capacitors of the non-self-healing type for AC power systems having a rated voltage up to and including 1000 V - Part 3: Internal fuses
IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors
NFC 54 102 : 88 AMD 1 92 SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V-GENERAL PERFORMANCE, TESTING & RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION & OPERATION
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60110:1973 Recommendation for capacitors for inductive heat generating plants operating at frequencies between 40 and 24 000 Hz
NFC 54 110 : 1992 COUPLING CAPACITORS AND CAPACITOR DIVIDERS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.