• There are no items in your cart

NF EN 61850-7-2 : 2003

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 7-2: BASIC COMMUNICATION STRUCTURE FOR SUBSTATION AND FEEDER EQUIPMENT - ABSTRACT COMMUNICATION SERVICE INTERFACE (ACSI)

Withdrawn date

15-10-2021

Published date

12-01-2013

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 ACSI overview and basic concepts
   5.1 General
   5.2 Overview of basic information models
   5.3 Overview of the other service models
   5.4 Overview of ACSI services
   5.5 Type definitions
6 SERVER class model
   6.1 SERVER class syntax
   6.2 Server class services
7 Application association model
   7.1 Introduction
   7.2 Concept of application associations
   7.3 Access control
   7.4 TWO-PARTY-APPLICATION-ASSOCIATION (TPAA) class model
   7.5 MULTICAST-APPLICATION-ASSOCIATION (MCAA) class
8 LOGICAL-DEVICE class model
   8.1 LOGICAL-DEVICE class definition
   8.2 LOGICAL-DEVICE class services
9 LOGICAL-NODE class mode
   9.1 LOGICAL-NODE class definition
   9.2 LOGICAL-NODE class services
10 DATA class model
   10.1 General
   10.2 DATA class definition
   10.3 Relation of DATA, common DATA, and compatible DATA classes
   10.4 DATA class services
11 DATA-SET class model
   11.1 General
   11.2 DATA-SET class definition
   11.3 DATA-SET class services
12 Substitution model
13 SETTING-GROUP-CONTROL-BLOCK class model
   13.1 General
   13.2 SGCB class definition
   13.3 SGCB class services
14 REPORT-CONTROL-BLOCK and LOG-CONTROL-BLOCK class models
   14.1 Overview
   14.2 REPORT-CONTROL-BLOCK class model
   14.3 LOG-CONTROL-BLOCK class model
15 Generic substation event class model (GSE)
   15.1 Overview
   15.2 GOOSE-CONTROL-BLOCK (GoCB) class
   15.3 Generic substation state event (GSSE) control block (sCB)
16 Transmission of sampled value class model
   16.1 Overview
   16.2 Transmission of sampled values using multicast
   16.3 Transmission of sampled values using unicast
   16.4 Sampled value format
17 CONTROL class model
   17.1 Introduction
   17.2 Control with normal security
   17.3 Control with enhanced security
   17.4 Time-activated operate
   17.5 CONTROL class service definitions
18 Time and time-synchronization model
   18.1 General
   18.2 External information
19 Naming conventions
   19.1 Class naming and class specializations
   19.2 Referencing an instance of a class
   19.3 Scope
20 File transfer
   20.1 File transfer model
   20.2 File services
Annex A (normative) ACSI conformance statement
A.1 General
A.2 ACSI models conformance statement
A.3 ACSI service conformance statement
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Bibliography
Index
Figures
Tables

Applies to ACSI communication in substations and feeder applications. Specifies device models and functions for additional activities, such as: - substation to substation information exchange; - substation to control centre information exchange; - power plant to control centre information exchange; - information exchange for distributed generation, or - information exchange for metering.

DevelopmentNote
Indice de classement: C46-908-7-2 PR NF EN 61850-7-2 July 2001 (07/2001)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Withdrawn
SupersededBy

Standards Relationship
DIN EN 61850-7-2:2011-04 Identical
BS EN 61850-7-2:2010 Identical
SN EN 61850-7-2 : 2003 Identical
I.S. EN 61850-7-2:2010 Identical
EN 61850-7-2:2010 Identical
IEC 61850-7-2:2010 Identical

NF EN 61850-7-4 : 2003 COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 7-4: BASIC COMMUNICATION STRUCTURE FOR SUBSTATION AND FEEDER EQUIPMENT - COMPATIBLE LOGICAL NODE CLASSES AND DATA CLASSES
NF EN 61850-6 : 2004 COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 6: CONFIGURATION DESCRIPTION LANGUAGE FOR COMMUNICATION IN ELECTRICAL SUBSTATIONS RELATED TO IEDS

IEC 61850-5:2013 Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models
IEC 61850-7-1:2011 Communication networks and systems for power utility automation - Part 7-1: Basic communication structure - Principles and models
IEC 61850-8-1:2011 Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3
IEC 61850-7-4:2010 Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
IEC 61850-7-3:2010 Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes

Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.