• NFC 14 100 : 2008 AMD 3 2016

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    LOW-VOLTAGE MAINS INSTALLATIONS

    Available format(s): 

    Superseded date:  09-07-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Domaine d'application et objet
    2 Normes et références réglementaires
    3 Définitions
    4 Maîtrise d'ouvrage des travaux de branchements
    5 Conception des branchements
    6 Liaison au réseau
    7 Canalisations collectives
    8 Dérivations individuelles
    9 Appareils de controle et de commande
    10 Circuit de communication du branchement
    11 Vérification et mise en service des installations de
       branchement
    Annexe A - (normative) - Calcul d'une installation collective
    Annexe B - (normative) - Calcul d'un lotissement
    Annexe C - (normative) - Schémas de canalisations
               collectives
    Annexe D - (normative) - Exemples de fixations des
               appareils de controle de commande et de
               protection
    Annexe E - (normative) - Circuit de communication du
               branchement
    Annexe F - (normative) - Conditions pour le fonctionnement
               en schéma TN d'une installation à puissance
               surveillée raccordée à un réseau de distribution
               publique basse tension
    Annexe G - (informative) - Eléments techniques des dossiers
               de branchement
    Annexe H - (informative) - Modèle d'autocontrole d'une
               colonne électrique
    Annexe J - (normative) - Immeubles existants
    Bibliographie

    Abstract - (Show below) - (Hide below)

    Les présentes règles sont applicables aux nouvelles réalisations de branchements à basse tension. Il est rappelé que, conformément à l'arrêté interministériel déterminant les conditions techniques auxquelles doivent satisfaire les distributions d'énergie électrique (1) la classification des ouvrages en domaines de tension est basée sur la valeur nominale de la tension (en valeur efficace pour le courant alternatif). Le domaine de tension basse tension comprend en particulier les ouvrages pour lesquels la valeur nominale de la tension ne dépasse pas 1000 V en courant alternatif, la plus grande des tensions entre deux conducteurs quelconques ou entre un conducteur et la terre ne devant pas dépasser la tension nominale de plus de 10%. Elles ne concernent pas les matériels des domaines haute tension A et B alimentant des postes de transformation quels qu'ils soient. Ces installations font l'objet d'autres règles ou textes (1), (2) et (3). Elles ne concernent pas les branchements électriques temporaires, destinés à la desserte en énergie d'installations ne présentant pas un caractère permanent, ni le caractère de véritable construction (telles que les installations de chantier, de fêtes foraines, de kermesses, de marchés, les installations mobiles de caravanes, de mobile homes, de péniches). Lorsque les conditions d'influences externes (4) sont rigoureuses, par exemple pour les zones particulièrement exposées aux effets de la foudre ou du givre, le gestionnaire du réseau de distribution peut être amené, en accord avec le service du controle de distribution d'énergie électrique, à édicter des prescriptions complémentaires. Les règles du présent document sont applicables également aux installations existant antérieurement mais seulement à l'occasion d'une refonte, d'une extension notable ou de transformations importantes. Dans le cas de transformations peu importantes, l'Annexe J est applicable.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de Classement: C14-100. (02/2002) PR NFC 14 100 September 2007. (09/2007)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFC 11 201 : 1996 AMD 1 2004 PUBLIC ELECTRICAL POWER SYSTEMS
    UTEC 15 722 : 2012 AMD 1 2016 INSTALLATIONS ELECTRIQUES A BASSE TENSION - GUIDE PRATIQUE - INSTALLATIONS D'ALIMENTATION DE VEHICULES ELECTRIQUES OU HYBRIDES RECHARGEABLES PAR SOCLES DE PRISES DE COURANT - EGALEMENT EDITE SOUS LA REFERENCE UTE C17-222
    UTEC 15 712-1 : 2013 INSTALLATIONS ELECTRIQUES A BASSE TENSION - GUIDE PRATIQUE - INSTALLATIONS PHOTOVOLTAIQUES SANS STOCKAGE ET RACCORDEES AU RESEAU PUBLIC DE DISTRIBUTION
    UTEC 15 712 : 2008 PHOTOVOLTAIC INSTALLATIONS
    UTEC 15 900 : 2006 ERECTION AND COEXISTENCE OF POWER AND COMMUNICATION NETWORKS IN RESIDENTIAL, TERTIARY AND ANALOG BUILDINGS
    UTEC 17 202 : 2007 INSTALLATIONS OF TEMPORARY ILLUMINATION BY GARLANDS, LIGHTING DECORATIVE SYSTEMS OR LUMINARIES
    UTEC 90 486 : 2013 TELECOM RISERS (FOR HOME AND HOME OFFICE)
    UTEC 17 222 : 2012 INSTALLATIONS ELECTRIQUES A BASSE TENSION - GUIDE PRATIQUE - INSTALLATIONS D'ALIMENTATION DE VEHICULES ELECTRIQUES OU HYBRIDES RECHARGEABLES PAR SOCLES DE PRISES DE COURANT - EGALEMENT EDITE SOUS LA REFERENCE UTE C15-722
    UTEC 15 400 : 2005 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - CONNECTION OF ELECTRIC GENERATORS IN INSTALLATIONS SUPPLIED BY A PUBLIC DISTRIBUTION NETWORK

    Standards Referencing This Book - (Show below) - (Hide below)

    NFC 11 201 : 1996 AMD 1 2004 PUBLIC ELECTRICAL POWER SYSTEMS
    NFC 68 102 : 1990 FITTINGS FOR WIRING - PROFILES USED FOR THE LAYING OF CABLES AND CORDS AND THEIR ACCESSORIES - REQUIREMENTS
    NFC 32 321 : 82 AMD 1 93 INSULATED CONDUCTORS AND CABLES FOR INSTALLATIONS - CROSS-LINKED POLYETHYLENE INSULATED RIGID CABLES WITH A PROTECTIVE SHEATH OF POLYVINYL CHLORIDE
    UTEC 12 061 : 1994 INSTALLATIONS SUBJECTED TO STATUTORY REGULATIONS - STATUTORY REGULATIONS ON PRECAUTIONS AGAINST FIRE IN LOFTY BUILDINGS
    NF EN 62056-31 : 2000 ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 31: USE OF LOCAL AREA NETWORKS ON TWISTED PAIR WITH CARRIER SIGNALLING
    NFC 33 210 : 1995 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - CROSS-LINKED POLYETHYLENE INSULATED CABLES COVERED WITH A POLYVINYL CHLORIDE SHEATH - TYPE H1 XDV-A
    UTEC 18 510 : 1988 COLLECTION OF GENERAL PROVISIONS FOR ELECTRICAL SAFETY
    NFC 33 400 : 2001 INSULATED CABLES FOR POWER SYSTEMS - ENERGY-METER INSTRUMENT CABLES
    UTEC 15 755 : 2005 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - ELECTRICAL INSTALLATIONS OF DIFFERENT ORIGINS IN A SAME LOCAL AND THE EXPLOITATIONS OF WHICH ARE PLACED UNDER DIFFERENT RESPONSIBILITIES
    UTEC 12 201 : 2008 STATUTORY REGULATIONS FOR THE PROTECTION AGAINST FIRE AND PANIC IN BUILDINGS OPEN TO THE PUBLIC - ABSTRACTS
    NFC 32 322 : 82 AMD 2 93 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CROSS-LINKED POLYETHYLENE INSULATED CABLES COVERED WITH A POLYVINYL CHLORIDE SHEATH, WITH A METALLIC ARMOUR
    UTEC 44 000 : AMD 87 STATUTORY REGULATIONS FOR INSPECTION OF ELECTRICITY METERS
    NFC 32 323 : 88 AMD 1 99 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS. HALOGEN-FREE 0,6/1 KV CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE, TYPE C1, WITH CROSS-LINKED SYNTHETIC INSULATION AND WITH EXTRUDED SYNTHETIC PROTECTIVE SHEATH
    NF EN 62262 : 2004 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES FOR ELECTRICAL EQUIPMENT AGAINST EXTERNAL MECHANICAL IMPACTS (IK CODES)
    NF EN 61386-22 : 2004 AMD 11 2011 CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 22: PARTICULAR REQUIREMENTS - PLIABLE CONDUIT SYSTEMS
    NFC 32 070 : 2001 AMD 1 2005 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CLASSIFICATION TESTS ON CABLES AND CORDS WITH RESPECT TO THEIR BEHAVIOUR TO FIRE
    NFC 13 100 : 2015 CONSUMER SUBSTATIONS FED BY HV PUBLIC DISTRIBUTION SYSTEM (UP TO 33 KV)
    UTEC 66 400 : 1972 EQUIPMENT FOR OVERHEAD POWER LINES - GALVANIZING OF FERROUS COMPONENTS: REQUIREMENTS
    UTEC 15 520 : 2007 WIRING SYSTEMS - METHODS OF INSTALLATION - CONNECTIONS
    UTEC 15 400 : 2005 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - CONNECTION OF ELECTRIC GENERATORS IN INSTALLATIONS SUPPLIED BY A PUBLIC DISTRIBUTION NETWORK
    NFC 62 411 : 1988 MAINS EQUIPMENT AND SIMILAR APPARATUS - RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS FOR CONSUMER'S CONTROL BOARDS IN LOW VOLTAGE INSTALLATIONS
    UTEC 15 103 : 2004 LOW-VOLTAGE INSTALLATIONS AND CORRESPONDING EQUIPMENT - SELECTION OF ELECTRICAL EQUIPMENT (INCLUDING WIRING SYSTEMS) IN RELATION TO EXTERNAL INFLUENCES
    NFC 62 412 : 83 AMD 2 2016 MAINS EQUIPMENT AND SIMILAR APPARATUS - CIRCUIT BREAKERS FOR CONSUMERS CONTROL BOARD IN LOW VOLTAGE SPECIAL INSTALLATIONS
    NFC 33 209 : 1996 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - BUNDLE ASSEMBLED CORES FOR OVERHEAD SYSTEMS OF RATED VOLTAGE 0,6/1 KV
    NFC 32 310 : 1996 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - FIRE RESISTANT CABLES AND FLEXIBLE CORDS FOR RATED VOLTAGE UP TO AND INCLUDING 0.6/1KV
    NFC 68 104 : 1990 FITTINGS FOR WIRING - PROFILE SYSTEMS USED FOR THE LAYING OF CABLES AND CORDS - REQUIREMENTS
    UTEC 68 118 : 2001 CONDUITS FOR ELECTRICAL PURPOSES - PARTICULAR REQUIREMENTS FOR CONDUIT SYSTEMS FOR ELECTRICAL INSTALLATIONS SITUATED BEFORE THE CUSTOMER BOARD
    NFC 15 100 : 2002 AMD 5 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective