• There are no items in your cart

NFC 32 201-3 : 1998 AMD 2 2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON-SHEATHED CABLES FOR FIXED WIRING

Superseded date

01-12-2014

Superseded by

NF EN 50525-2-31 : 2012

Published date

12-01-2013

Sorry this product is not available in your region.

1 Domaine d'application
2 Conducteur à âme rigide pour usage général
  2.1 Désignation
  2.2 Tension assignée
  2.3 Constitution
  2.4 Essais
  2.5 Guide d'emploi
3 Conducteur à âme souple pour usage général
  3.1 Désignation
  3.2 Tension assignée
  3.3 Constitution
  3.4 Essais
  3.5 Guide d'emploi
4 Conducteur à âme massive pour filerie interne
  4.1 Désignation
  4.2 Tension assignée
  4.3 Constitution
  4.4 Essais
  4.5 Guide d'emploi
5 Conducteur à âme souple pour filerie interne
  5.1 Désignation
  5.2 715 Tension assignée
  5.3 Constitution
  5.4 Essais
  5.5 Guide d'emploi
Annexe A (normative) Références normatives
Annexe B (informative) Références informatives
Annexe C - Correspondance entre les documents internationaux
           cités en référence et les documents CENELEC
           et/ou Français à appliquer

Ce document introduit les spécifications particulières applicables aux conducteurs pour installations fixes ayant une enveloppe en polychlorure de vinyle de tension assignée au plus égale à 450/750 V.

DevelopmentNote
PR NFC 32-201-3 March 1999. Indice de classement: C32-201-3. (02/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
HD 21-3 : S3 AMD 2 2008 Identical
IEC 60227-3:1993+AMD1:1997 CSV Identical

NFC 32 340 : 95 XP INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - POLYETHYLENE INSULATED CABLES COVERED WITH POLYVINYL CHLORIDE SHEATH FOR CABLING AND PRECABLING OF HOME ELECTRONIC SYSTEMS
NF EN 61058-2-4 : 2005 SWITCHES FOR APPLIANCES - PART 2-4: PARTICULAR REQUIREMENTS FOR INDEPENDENTLY MOUNTED SWITCHES

NF EN 60719 : 1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
IEC 60228:2004 Conductors of insulated cables
HD 405.1 : S1 AMD 1 TESTS ON ELECTRIC CABLES UNDER FIRE CONDITIONS - TEST ON A SINGLE VERTICAL INSULATED WIRE OR CABLE
IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
IEC 60719:1992 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 32 070 : 2001 AMD 1 2005 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CLASSIFICATION TESTS ON CABLES AND CORDS WITH RESPECT TO THEIR BEHAVIOUR TO FIRE
IEC 60228A:1982 First supplement - Conductors of insulated cables - Guide to the dimensional limits of circular conductors
NFC 32 080 : 1998 AMD 2 2009 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.