• NFPA 72A : 1987

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    INSTALLATION, MAINTENANCE, AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS

    Available format(s): 

    Superseded date:  17-08-1990

    Language(s): 

    Published date:  12-01-2013

    Publisher:  National Fire Protection Association

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Chapter 1 Fundamentals
    1.1 Scope
    1.2 Definitions
    Chapter 2 General Requirements
    2.1 Purpose
    2.2 Approval and Acceptance
    2.3 Maintenance and Testing
    2.4 Drills and Periodic Tests
    2.5 Installation and Design
    2.6 Power Supply Sources
    2.7 Monitoring Integrity of Installation Conductors
    2.8 Audible Signal Appliances
    2.9 Capacity of Circuits for Coded Systems
    2.10 Combination Systems
    2.11 Visual Zone Alarm Indication
    2.12 Performance of Initiating Device Circuits
    2.13 Performance of Signaling Line Circuits
    2.14 Performance of Indicating Appliance Circuits
    2.15 Special Requirements for Alarm Signals From a
          Low Power Wireless System
    2.16 Protection of Control Equipment
    Chapter 3 Types of Signaling Services
    3.1 Purpose
    3.2 Manual Fire Alarm Service
    3.3 Guard's Tour Supervisory Service
    3.4 Automatic Fire Detection and Alarm Service
    3.5 Sprinkler System Waterflow Alarm and Supervisory
          Signal Service
    Chapter 4 Referenced Publications
    Appendix A
    Appendix B Referenced Publications
    Index

    Abstract - (Show below) - (Hide below)

    Applies to fire alarm or supervisory signals which are for the protection of life and property.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Fire Protection Association
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFPA 14A : 1989 INSPECTION, TESTING AND MAINTENANCE OF STANDPIPE AND HOSE SYSTEMS
    NFPA 61B : 1989 PREVENTION OF FIRES AND EXPLOSIONS IN GRAIN ELEVATORS AND FACILITIES HANDLING BULK RAW AGRICULTURAL COMMODITIES
    NFPA 72G : 1989 INSTALLATION, MAINTENANCE, AND USE OF NOTIFICATION APPLIANCES FOR PROTECTIVE SIGNALING SYSTEMS
    NFPA 26 : 1988 SUPERVISION OF VALVES CONTROLLING WATER SUPPLIES
    NFPA 72B : 1986 INSTALLATION, MAINTENANCE, AND USE OF AUXILIARY PROTECTIVE SIGNALING SYSTEMS
    NFPA 71 : 1989 INSTALLATION, MAINTENANCE, AND USE OF SIGNALING SYSTEMS FOR CENTRAL STATION SERVICE
    NFPA 231E : 1996 STORAGE OF BALED COTTON
    NFPA 88B : 1997 REPAIR GARAGES
    ANSI A225.1 : 1987 MANUFACTURED HOME INSTALLATIONS
    NFPA 72C : 1986 INSTALLATION, MAINTENANCE, AND USE OF REMOTE STATION PROTECTIVE SIGNALING SYSTEMS
    NFPA 13A : 1987 INSPECTION, TESTING, AND MAINTENANCE OF SPRINKLER SYSTEMS
    NFPA 913 : 1992 HISTORIC SITES AND STRUCTURES
    NFPA 72H : 1988 TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
    NFPA 72F : 1985 INSTALLATION, MAINTENANCE, AND USE OF EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS
    NFPA 903M : 1986 FIRE REPORTING PROPERTY SURVEY MANUAL
    NFPA 81 : 1986 FUR STORAGE, FUMIGATION AND CLEANING
    IEEE 241 : 1990 ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS
    FIPS PUB 31 : 0 GUIDELINES FOR AUTOMATIC DATA PROCESSING PHYSICAL SECURITY AND RISK MANAGEMENT
    NFPA 72D : 1986 INSTALLATION, MAINTENANCE, AND USE OF PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
    NFPA 61D : 1989 PREVENTION OF FIRE AND DUST EXPLOSIONS IN THE MILLING OF AGRICULTURAL COMMODITIES FOR HUMAN CONSUMPTION
    NFPA 61A : 1989 PREVENTION OF FIRE AND DUST EXPLOSIONS IN FACILITIES MANUFACTURING AND HANDLING STARCH
    NFPA 61C : 1989 PREVENTION OF FIRE AND DUST EXPLOSION IN FEED MILLS
    NFPA 74 : 1989 HOUSEHOLD FIRE WARNING EQUIPMENT

    Standards Referencing This Book - (Show below) - (Hide below)

    NFPA 72E : 1990 AUTOMATIC FIRE DETECTORS
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    NFPA 601 : 2015 SECURITY SERVICES IN FIRE LOSS PREVENTION
    NFPA 600 : 2015 INDUSTRIAL FIRE BRIGADES
    NFPA 13 : 2016 INSTALLATION OF SPRINKLER SYSTEMS
    NFPA 72H : 1988 TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
    NFPA 37 : 2018 INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES
    NFPA 602 : 1986 GUARD OPERATIONS IN FIRE LOSS PREVENTION
    NFPA 72G : 1989 INSTALLATION, MAINTENANCE, AND USE OF NOTIFICATION APPLIANCES FOR PROTECTIVE SIGNALING SYSTEMS
    NFPA 20 : 2016 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective