PD 7639-2:1994
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Short-circuit current calculation in three-phase a.c. systems Data for electrical equipment for short-circuit current calculations in accordance with BS 7639
Hardcopy , PDF
31-01-2009
English
15-04-1994
Committees responsible
National foreword
Section 1. General
1.1 Scope and object
1.2 Reference documents
Section 2. Data for electrical equipment
2.1 General
2.2 Data on typical synchronous machines
2.3 Data on typical transformers, two-winding, three-
winding and auto-transformers
2.4 Data on typical overhead lines, single and double
circuits
2.5 Data on typical low- and high-voltage cables
2.6 Data on typical asynchronous motors
2.7 Busbars
Tables
1 Information received from National Committees
2 Actual data of typical synchronous generators,
condensers and motors
3A Actual data of typical two-winding transformers
3B Actual data of typical three-winding transformers
3C Actual data of typical autotransformers with and
without tertiary winding
4 Actual data of typical overhead lines (single and
double circuit 50 and 60 Hz) per circuit
5 Actual data of typical electric cables
6 Actual data of typical asynchronous motors
7 Actual data of distribution busbar
Figures
1 Subtransient reactance of synchronous machines
(motors SM, condensers SC, turbogenerators and
salient pole generators) 50 Hz and 60 Hz
2 Rated voltage UrG and rated power factor cos phi rG
of synchronous machines (motors, condensers,
turbogenerators and salient pole generators) 50 Hz
and 60 Hz
3 Unsaturated and saturated synchronous reactances of
two-pole turbogenerators 50 Hz (n = 3 000 /min)
and 60 Hz (n = 3 600 /min)
4 Rated short-circuit voltage ukr of power station
generator transformers (PT) with or without tap-
changer
5 Rated short-circuit voltage ukr of network
transformers
6 Positive-sequence reactance X'(1)L of low-voltage
and medium-voltage overhead lines 50 Hz, Cu or Al
7 Positive-sequence reactance X'(1)L of overhead
lines 50 Hz
8 Type of line
9 Positive-sequence reactance X'(1) of low-voltage
cables Cu or Al, 50 Hz (Germany)
10 Positive-sequence reactance X'(1) of medium-voltage
cables, 50 Hz
11 Low-voltage cables 0,6/1kV, positive-sequence
reactance X'(1) and ratios R(0)/R(1) and X(0)/X(1).
Copper conductors and return circuits a, b, c, d
12 Low-voltage cables 0,6/1kV, positive-sequence
reactance X'(1) and ratios R(0)/R(1) and X(0)/X(1).
Aluminium conductors and return circuits a, b, c, d
13 Low-voltage cables 0,6/1kV, type A, with four
conductors Cu or Al (Germany), R(0)/R(1) and
X(0)/X(1)
14 Low-voltage cables 0,6/1kV, type A, with three and
a half copper conductors (Germany), R(0)/R(1) and
X(0)/X(1)
15 Low-voltage cables 0,6/1kV, type B, with four
conductors Cu or Al and a concentric conductor Cu
(Germany), R(0)/R(1) and X(0)/X(1)
16 Low-voltage cables 0,6/1kV, type B, with three
conductors Cu or Al and a concentric conductor Cu
(Germany), R(0)/R(1) and X(0)/X(1). The concentric
conductor has the same cross-section as the main
conductor
17 Low-voltage cables 0,6/1kV, type B, with three
conductors Cu or Al and a concentric conductor Cu
(Germany), R(0)/R(1) and X(0)/X(1). The concentric
conductor has half the cross-section as the
main conductor
18 Low-voltage cables 0,6/1kV, type C, with three
conductors Cu or Al and aan aluminium sheath
(Germany), R(0)/R(1) and X(0)/X(1)
19 Low-voltage cables 0,6/1kV, type D, with four
conductors Cu or Al and a lead sheath with steel
armouring (Germany), R(0)/R(1) and X(0)/X(1)
20 Low-voltage cables 0,6/1kV, type D, with three and
a half conductors Cu or Al and a lead sheath with
steel armouring (Germany), R(0)/R(1) and X(0)/X(1)
21 Locked-rotor currents ILR/IrM of low-voltage and
medium-voltage asynchronous motors, 50 Hz and 60 Hz
22 Product cos phi rM.eta r of low-voltage and medium-
voltage asynchronous motors, 50 Hz and 60 Hz
Comprises data collected from different countries to be used when necessary for calculating short-circuit currents in accordance with BS 7638:1993 and BS 7639:1994.
Committee |
W/-
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 4727(1971) : LATEST | |
BS 7639:1993 | Short-circuit current calculation in three-phase a.c. systems |
BS 7638:1993 | Application guide for calculation of short-circuit currents in low-voltage radial systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.