INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Summary of published test methods
  4.1 Tests using heated air or electrical heating
      4.1.1 Determination of ignition temperature using a
            hot-air furnace, ISO 871
      4.1.2 Differential scanning calorimetry, ISO 11357
  4.2 Tests using radiant heat
      4.2.1 Heat release rate - Cone calorimeter method,
            ISO 5660-1
      4.2.2 Heat release of insulating liquids, IEC 60695-8-3
      4.2.3 Standard test method for determining material ignition
            and flame spread properties, ASTM E1321
      4.2.4 Determination of the ignition characteristic heat
            flux from a non-contacting flame source,
            IEC 60695-11-11
  4.3 Oxygen index tests
      4.3.1 Oxygen index - Ambient temperature test, ISO 4589-2
      4.3.2 Oxygen index - Elevated temperature test, ISO 4589-3
  4.4 Glowing/hot-wire based test methods
      4.4.1 Glow wire tests, IEC 60695-2-11, -12 & -13
      4.4.2 Hot wire coil ignitability test, IEC 60695-2-20 and
            ANSI/ASTM D3874
  4.5 Flame tests
      4.5.1 Needle flame test, IEC 60695-11-5
      4.5.2 50 W Horizontal and vertical flame test methods,
            IEC 60695-11-10 500 W flame test methods,
            IEC 60695-11-20
      4.5.3 1 kW nominal pre-mixed flame, IEC 60695-11-2
      4.5.4 Vertical and 60 degrees tests for aircraft
            components, FAR 25
  4.6 Tests using an electrical arc
      4.6.1 Tracking index test, IEC 60112
      4.6.2 High-Current Arc Ignition (HAI), UL 746A - Sec. 43
      4.6.3 High-Voltage Arc Resistance to Ignition (HVAR),
            UL 746A - Sec. 44
Annex A (informative) - Applicability of test methods
Bibliography

Gives a summary of test methods that are used to determine the ignitability of electrotechnical products or materials from which they are formed.

Committee
GEL/89
DevelopmentNote
Supersedes 06/30144845 DC. (09/2008)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

IEC/TR 60695-1-21:2008 provides a summary of test methods that are used to determine the ignitability of electrotechnical products or materials from which they are formed. It also includes test methods in which, by design, ignitability is a significant quantifiable characteristic. This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.

Standards Relationship
IEC TR 60695-1-21:2008 Identical

09/30166429 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
BS 8492(2016) : 2016 TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
16/30336629 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
BS 8492:2009 Telecommunications equipment and telecommunications cabling. Code of practice for fire performance and protection

IEC 60695-11-20:2015 Fire hazard testing - Part 11-20: Test flames - 500 W flame test method
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
ISO 4589-3:2017 Plastics — Determination of burning behaviour by oxygen index — Part 3: Elevated-temperature test
ISO 5660-1:2015 Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)
IEC TS 60695-1-20:2008 Fire hazard testing - Part 1-20: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - General guidance
ISO 871:2006 Plastics Determination of ignition temperature using a hot-air furnace
IEC 60695-1-30:2017 Fire hazard testing - Part 1-30: Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines
IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
IEC TS 60695-8-3:2008 Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products
ISO 5660-2:2002 Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement)
ISO 13943:2017 Fire safety — Vocabulary
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 60695-11-2:2017 Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
IEC 60695-2-13:2010+AMD1:2014 CSV Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials
ISO/IEC Guide 51:2014 Safety aspects — Guidelines for their inclusion in standards
IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
IEC TS 60695-11-40:2002 Fire hazard testing - Part 11-40: Test flames - Confirmatory tests - Guidance
IEC TR 62062:2002 Results of the Round Robin series of tests to evaluate proposed amendments to IEC 60112
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
UL 746A:6ED 2012-09-06 Polymeric Materials - Short Term Property Evaluations
IEC TS 60695-11-3:2004 Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods
ISO 4589-2:2017 Plastics — Determination of burning behaviour by oxygen index — Part 2: Ambient-temperature test
IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
IEC TS 60695-11-4:2004 Fire hazard testing - Part 11-4: Test flames - 50 W flame - Apparatus and confirmational test method
IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
ISO 4589-1:2017 Plastics — Determination of burning behaviour by oxygen index — Part 1: General requirements