INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Summary of published test methods
4.1 Tests using heated air or electrical heating
4.1.1 Determination of ignition temperature using a
hot-air furnace, ISO 871
4.1.2 Differential scanning calorimetry, ISO 11357
4.2 Tests using radiant heat
4.2.1 Heat release rate - Cone calorimeter method,
ISO 5660-1
4.2.2 Heat release of insulating liquids, IEC 60695-8-3
4.2.3 Standard test method for determining material ignition
and flame spread properties, ASTM E1321
4.2.4 Determination of the ignition characteristic heat
flux from a non-contacting flame source,
IEC 60695-11-11
4.3 Oxygen index tests
4.3.1 Oxygen index - Ambient temperature test, ISO 4589-2
4.3.2 Oxygen index - Elevated temperature test, ISO 4589-3
4.4 Glowing/hot-wire based test methods
4.4.1 Glow wire tests, IEC 60695-2-11, -12 & -13
4.4.2 Hot wire coil ignitability test, IEC 60695-2-20 and
ANSI/ASTM D3874
4.5 Flame tests
4.5.1 Needle flame test, IEC 60695-11-5
4.5.2 50 W Horizontal and vertical flame test methods,
IEC 60695-11-10 500 W flame test methods,
IEC 60695-11-20
4.5.3 1 kW nominal pre-mixed flame, IEC 60695-11-2
4.5.4 Vertical and 60 degrees tests for aircraft
components, FAR 25
4.6 Tests using an electrical arc
4.6.1 Tracking index test, IEC 60112
4.6.2 High-Current Arc Ignition (HAI), UL 746A - Sec. 43
4.6.3 High-Voltage Arc Resistance to Ignition (HVAR),
UL 746A - Sec. 44
Annex A (informative) - Applicability of test methods
Bibliography
Gives a summary of test methods that are used to determine the ignitability of electrotechnical products or materials from which they are formed.
Committee |
GEL/89
|
DevelopmentNote |
Supersedes 06/30144845 DC. (09/2008)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC/TR 60695-1-21:2008 provides a summary of test methods that are used to determine the ignitability of electrotechnical products or materials from which they are formed. It also includes test methods in which, by design, ignitability is a significant quantifiable characteristic. This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.
Standards | Relationship |
IEC TR 60695-1-21:2008 | Identical |
09/30166429 DC : 0 | BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
BS 8492(2016) : 2016 | TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
16/30336629 DC : 0 | BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
BS 8492:2009 | Telecommunications equipment and telecommunications cabling. Code of practice for fire performance and protection |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
ISO 4589-3:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 3: Elevated-temperature test |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
IEC TS 60695-1-20:2008 | Fire hazard testing - Part 1-20: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - General guidance |
ISO 871:2006 | Plastics Determination of ignition temperature using a hot-air furnace |
IEC 60695-1-30:2017 | Fire hazard testing - Part 1-30: Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
IEC TS 60695-8-3:2008 | Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products |
ISO 5660-2:2002 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement) |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60695-11-2:2017 | Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC TS 60695-11-40:2002 | Fire hazard testing - Part 11-40: Test flames - Confirmatory tests - Guidance |
IEC TR 62062:2002 | Results of the Round Robin series of tests to evaluate proposed amendments to IEC 60112 |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
UL 746A:6ED 2012-09-06 | Polymeric Materials - Short Term Property Evaluations |
IEC TS 60695-11-3:2004 | Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods |
ISO 4589-2:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 2: Ambient-temperature test |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
IEC TS 60695-11-4:2004 | Fire hazard testing - Part 11-4: Test flames - 50 W flame - Apparatus and confirmational test method |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
ISO 4589-1:2017 | Plastics — Determination of burning behaviour by oxygen index — Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.