PIP PNE00003 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PROCESS UNIT AND OFFSITES LAYOUT GUIDE
Hardcopy , PDF
21-02-2019
English
01-01-2013
1. Introduction
2. References
3. Definitions
4. General
5. Site Plan Development
6. Accessways, Platforms, Fixed Industrial Stairs,
Fixed Ladders
7. Roadways and Area Paving
8. Piping
9. Buildings
10. Instrument and Electrical Equipment
11. Equipment and Instrument Access
12. Cooling Towers
13. Storage Tanks
14. Gas Processing, Storage and Terminal
Facilities
15. Miscellaneous Considerations
Defines the guidelines for the layout of plot areas, equipment, pipe racks, piping, platforms, roadways, and other miscellaneous items. Should be used as a starting point for the development of plans, electronic models, and working drawings for process units and offsites.
DocumentType |
Standard
|
Pages |
23
|
PublisherName |
Process Industry Practices
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
PIP PNC00005 : 2016 | DESIGN OF ASME B31.3 - METALLIC PIPING SYSTEMS |
PIP PNE00002 : 2019 | PIPING MATERIAL SPECIFICATION SELECTION, DEVELOPMENT, AND APPLICATION GUIDELINES |
PIP CVE02350M : 2012 | ROADWAY DESIGN GUIDE (METRIC) |
PIP CVE02350 : 2012 | ROADWAY DESIGN GUIDE (U.S. CUSTOMARY) |
PIP PLC00005 : 2016 | DESIGN OF ASME B31.8 METALLIC PIPELINE SYSTEMS WITHIN FACILITIES |
PIP CVC01017 : 2011 | PLANT SITE DATA SHEET |
PIP CVC01015 : 2013 | CIVIL DESIGN CRITERIA |
PIP PNE00002 : 2013 | PIPING MATERIAL SPECIFICATION SELECTION, DEVELOPMENT, AND APPLICATION GUIDELINES |
PIP PLC00005:2018 | Design of ASME B31.8 Metallic Pipeline Systems within Facilities |
UFC 4-020-01 : 2008 | UNIFIED FACILITIES CRITERIA - DOD SECURITY ENGINEERING FACILITIES PLANNING MANUAL |
API 500 : 2012 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
NFPA 58 : 2017 | LIQUEFIED PETROLEUM GAS CODE |
CFR 29(PTS1900-1910) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
NFPA 101 : 2018 | LIFE SAFETY CODE |
PIP STE01100 : 2016 | CONSTRUCTABILITY DESIGN GUIDE |
CFR 40(PTS260-265) : JUL 2017 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |
CFR 40(PTS100-135) : JUL 2017 | PROTECTION OF ENVIRONMENT |
API 521 : 2014 | PRESSURE-RELIEVING AND DEPRESSURING SYSTEMS |
ICC 2012 INTERNATIONAL FIRE CODE : 2012 | INTERNATIONAL FIRE CODE |
PIP CVE02350 : 2012 | ROADWAY DESIGN GUIDE (U.S. CUSTOMARY) |
IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |
API 625 : 2010 | TANK SYSTEMS FOR REFRIGERATED LIQUEFIED GAS STORAGE |
API 505 : 1997 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2 |
NFPA 59 : 2018 | UTILITY LP-GAS PLANT CODE |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
ACI 376 : 2011 | CODE REQUIREMENTS FOR DESIGN AND CONSTRUCTION OF CONCRETE STRUCTURES FOR THE CONTAINMENT OF REFRIGERATED LIQUEFIED GASES AND COMMENTARY |
NFPA 59A : 2016 | PRODUCTION, STORAGE, AND HANDLING OF LIQUEFIED NATURAL GAS (LNG) |
NFPA 1 : 2018 | FIRE CODE |
PIP CVE02350M : 2012 | ROADWAY DESIGN GUIDE (METRIC) |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
CFR 28(PTS 0-42) : JUL 2017 | JUDICIAL ADMINISTRATION - DEPARTMENT OF JUSTICE |
API 752 : 2009 | MANAGEMENT OF HAZARDS ASSOCIATED WITH LOCATION OF PROCESS PLANT PERMANENT BUILDINGS |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.