1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES

Determines the requirements for various kinds and colors of electrical insulating sleeving which will shrink to a predetermined size upon applying heat.Includes provisions for demonstration of compliance with requirements through in process inspection and statistical process control. Continuous operating temperatures are in the range -80 deg to +250 deg C (-112 deg to + 482 deg F).

DevelopmentNote
Supersedes MIL DTL 23053 (08/1999)
DocumentType
Standard
PublisherName
SAE International
Status
Superseded
SupersededBy

This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with requirements through in process inspection and statistical process control (see 4.4.3.1). Continuous operating temperature ratings range from -80° to +250°C (-112° to +482°F) (see 6.1).

Standards Relationship
MIL-DTL-23053 Revision E:1996 Identical

SAE AS95234 Connectors, Electrical, Reverse Bayonet, General Specification For
MIL-PRF-32517 Base Document:2015 SPLICE, CONDUCTOR, ELECTRICAL, COAXIAL CABLE, MATCHED IMPEDANCE, GENERAL SPECIFICATION FOR
SAE AS95234A Connectors, Electrical, Reverse Bayonet, General Specification for
MIL-STD-1678-1 Revision D:2016 FIBER OPTIC CABLING SYSTEMS REQUIREMENTS AND MEASUREMENTS - PART 1: DESIGN, INSTALLATION AND MAINTENANCE REQUIREMENTS (PART 1 OF 6 PARTS)
MIL-PRF-39003 Revision N:2016 Capacitor, Fixed, Electrolytic (Solid Electrolyte), Tantalum, Established Reliability, General Specification for
MIL-STD-2003-5 Revision A:2009 ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CONNECTORS)
MIL-DTL-917 Revision F:2014 ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR
SAE ARP4945A Aerospace-Solenoid Valve, Hydraulic, Three Way, Two Position, Direct Acting
I.S. EN 6049-009:2016 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 009: SELF-WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE, POST INSTALLATION, OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
BS EN 6049-009:2016 Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Self-wrapping fire protection sleeve, flexible, post installation, operating temperature from -55 °C to 260 °C. Product standard
MIL-DTL-2726-49 Revision F:2013 RECEPTACLE, OUTLET, TRIPLE, ELECTRICAL, 40 - AMPERE, 450 - VOLT, 60 HERTZ, ALTERNATING CURRENT, 4 - POLE, PORTABLE, PLASTIC GROUNDED (SYMBOL NOS. 765.6, 765.7 AND 765.8)
PD ISO/TR 21891:2017 Aerospace electrical requirements. Sleeves and moulded shapes. Specifications for aircraft use
MIL-DTL-15024-8 Revision A:2014 Plate, Tags and Bands, Band Identification, Cable Assembly, Type K2, Heat Shrinkable Tubing
NASA KSC E 165 : 2009 ELECTRICAL GROUND SUPPORT EQUIPMENT FABRICATION, SPECIFICATION FOR
NASA KSC GP 864 VOL 2A : 2009 ELECTRICAL GROUND SUPPORT EQUIPMENT CABLE HANDBOOK
NASA KSC STD 132 : 2008 POTTING AND MOLDING ELECTRICAL CABLE ASSEMBLY TERMINATIONS, STANDARD FOR
MIL-HDBK-522 Revision A:2016 GUIDELINES FOR INSPECTION OF AIRCRAFT ELECTRICAL WIRING INTERCONNECT SYSTEMS
MIL-STD-2042-5 Revision C:2016 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CONNECTORS AND INTERCONNECTIONS) (PART 5 OF 7 PARTS)
EN 6049-009:2016 Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 009: Self-wrapping fire protection sleeve, flexible, post installation, operating temperature from -55 °C to 260 °C - Product standard
PREN 6049-009 : 200P3 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 009: SELF-WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
12/30275061 DC : 0 BS EN 6049-009 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTIVE SLEEVE IN ARAMID FIBRES - PART 009: SELF WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
SAE AS50881F Wiring Aerospace Vehicle
MIL-PRF-39006 Revision G:2006 CAPACITOR, FIXED, ELECTROLYTIC (NONSOLID ELECTROLYTE), TANTALUM, ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR
SAE AS 5258 : 2012 INSULATING COMPONENT, MOLDED, ELECTRICAL, HEAT SHRINKABLE, CONNECTOR AND CABLE ACCESSORY, SEALING STRAIN RELIEF, GENERAL SPECIFICATION FOR
SAE AS 6224 : 2015 WRAP-AROUND INSULATION REPAIR AND PROTECTION SLEEVE, PERMANENT, ELECTRIC, ENVIRONMENT RESISTANT

MIL-DTL-23053-8 Revision C:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYVINYLIDENE FLUORIDE, SEMI-RIGID, CROSSLINKED
MIL L 7808 : K (1) LUBRICATING OIL, AIRCRAFT TURBINE ENGINE, SYNTHETIC BASE
FED-STD-228 Revision A:2014 TEST METHODS FOR CABLES AND WIRE, INSULATED
MIL-I-23053-3 Revision A:1976 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYVINYL CHLORIDE, SEMI RIGID, CROSSLINKED AND NON CROSSLINKED
MIL-DTL-23053-14 Revision B:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, ETHYLENE-TETRAFLUOROETHYLENE FLUOROPOLYMER, SEMI-RIGID
MIL-DTL-23053-17 Revision B:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLAME RETARDED, MODIFIED POLYOLEFIN, FLEXIBLE, CROSSLINKED
MIL-DTL-23053-10 Revision D:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, SILICONE RUBBER, FLEXIBLE
MIL-DTL-23053-18 Revision B:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, MODIFIED FLUOROPOLYMER, CROSSLINKED
MIL-DTL-23053-7 Revision C:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYETHYLENE TEREPHTHALATE, NON-CROSSLINKED
ASTM G 21 : 2015 : REDLINE Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
MIL L 23699 : E LUBRICATING OIL, AIRCRAFT TURBINE ENGINES, SYNTHETIC BASE
A-A-694 Revision E:2013 Sodium Chloride, Technical
MIL-DTL-23053-13 Revision B:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLUOROELASTOMER FLEXIBLE
MIL T 5624 : R TURBINE FUEL, AVIATION, GRADES JP 4 AND JP 5
MIL-DTL-23053-15 Revision B:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, HEAVY-WALL, COATED, FLEXIBLE, OUTER WALL CROSSLINKED
ASTM D 792 : 2013 : REDLINE Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
MIL-I-23053-2 Revision C:1976 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYVINYL CHLORIDE, FLEXIBLE, CROSSLINKED AND NON CROSSLINKED
MIL I 23053/9 : LATEST INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLUOROSILICONE RUBBER, FLEXIBLE
MIL-DTL-23053-16 Revision B:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, CROSSLINKED, ELASTOMERIC POLYOLEFIN, FLEXIBLE
MIL-DTL-23053-5 Revision C:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, FLEXIBLE, CROSSLINKED
MIL-DTL-23053-11 Revision C:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLUORINATED ETHYLENE PROPYLENE, NON-CROSSLINKED
ASTM D 876 : 2013 : REDLINE Standard Test Methods for Nonrigid Vinyl Chloride Polymer Tubing Used for Electrical Insulation
MIL-A-8243 Revision D:1985 ANTI-ICING AND DEICING-DEFROSTING FLUIDS
MIL-DTL-23053-12 Revision C:1996 INSULATION SLEEVING - ELECTRICAL, HEAT SHRINKABLE, POLYTETRAFLUOROETHYLENE
MIL-DTL-23053-1 Revision C:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, CROSSLINKED CHLORINATED POLYOLEFIN, FLEXIBLE
MIL H 5606 : G HYDRAULIC FLUID, PETROLEUM BASE; AIRCRAFT; MISSILE AND ORDNANCE
MIL F 46162 : D FUEL, DIESEL, REFEREE GRADE
ASTM D 570 : 1998 : R2018 Standard Test Method for Water Absorption of Plastics
MIL-DTL-23053-6 Revision D:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, SEMI-RIGID, CROSSLINKED
MIL-STD-104 Revision C:1986 LIMITS FOR ELECTRICAL INSULATION COLOR
ASTM D 638 : 2014 : REDLINE Standard Test Method for Tensile Properties of Plastics
MIL-DTL-23053-4 Revision D:1996 INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, DUAL-WALL, OUTER WALL CROSSLINKED
ASTM D 2671 : 2013 Standard Test Methods for Heat-Shrinkable Tubing for Electrical Use
ASTM D 374 : 1999 Standard Test Methods for Thickness of Solid Electrical Insulation
ASTM D 746 : 2014 : REDLINE Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.