SN EN 60601-2-16 : 1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-16: PARTICULAR REQUIREMENTS FOR THE SAFETY OF HAEMODIALYSIS, HAEMODIAFILTRATION AND HAEMOFILTRATION EQUIPMENT
23-11-2021
12-01-2013
Foreword
Introduction
Section 1. General
1 Scope and object
2 Terminology and definitions
3 General requirements
6 Identification, marking and documents
Section 2. Environmental conditions
Section 3. Protection against electric shock hazards
19 Continuous LEAKAGE CURRENT and PATIENT AUXILIARY
CURRENTS
Section 4. Protection against mechanical hazards
Section 5. Protection against hazards from unwanted
or excessive radiation
36 Electromagnetic compatibility
Section 6. Protection against hazards of ignition of
flammable anaesthetic mixtures
Section 7. Protection against excessive temperatures
and other safety hazards
44 Overflow, spillage, leakage, humidity, ingress of
liquids, cleaning, sterilization and disinfection
49 Interruption of the power supply
Section 8. Accuracy of operating data and protection
against hazardous output
51 Protection against hazardous output
Section 9. Abnormal operation and fault conditions;
environmental tests
Section 10. Constructional requirements
54 General
56 Components and general assembly
57 MAINS PARTS, components and layout
Annex L - References - Publications mentioned in this
standard
Annex AA (informative) General guidance and rationale
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Annex ZB (informative) Other international publications
mentioned in this standard with the references
of the relevant European publications
Table 1 - PROTECTIVE SYSTEM inspection times
Defines the minimum safety requirements for single patient haemodialysis, haemodiafiltration and haemofiltration equipment meant to be used either by medical staff or under their supervision, including operation of the equipment by the patient.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 60601-2-16:2015 | Identical |
I.S. EN 60601-2-16:2015 | Identical |
DIN EN 60601-2-16 : 2016 | Identical |
NF EN 60601-2-16 : 2015 | Identical |
BS EN 60601-2-16:2015 | Identical |
UNE-EN 60601-2-16:1999 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.