• There are no items in your cart

UNE-EN 1434-4:2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Heat meters - Part 4: Pattern approval tests

Available format(s)

Hardcopy , PDF

Superseded date

12-06-2019

Language(s)

Spanish, Castilian, English

Published date

06-04-2016

€118.80
Excluding VAT

Foreword
1 Scope
2 Normative references
3 General
4 Requirements
5 Specification of operating conditions
    5.1 Rated operating conditions
    5.2 Reference conditions
    5.3 Reference values for the measurand, RVM
          5.3.1 Reference values for the measurand
                  RVM for qp><-3,5 m3/h
          5.3.2 Reference values for the measurand
                  RVM for qp>3,5m3/h
6 Tests and measurements
    6.1 General
    6.2 Test programme
    6.3 Uncertainty of test equipment
    6.4 Performance test
          6.4.1 Flow sensor
          6.4.2 Calculator
          6.4.3 Temperature sensors
          6.4.4 Combined sub-assemblies or complete meter
    6.5 Dry heat
          6.5.1 Calculator
          6.5.2 Flow sensor
          6.5.3 Combined sub-assemblies or complete meter
    6.6 Cold
          6.6.1 Calculator
          6.6.2 Flow sensor
          6.6.3 Combined sub-assemblies or complete meter
    6.7 Static deviations in supply voltage
    6.8 Durability test
          6.8.1 Flow sensor
          6.8.2 Temperature sensors
          6.8.3 Combined sub-assemblies or complete meter
    6.9 Damp heat cyclic
    6.10 Short time mains voltage reduction
    6.11 Electrical transients
          6.11.1 Fast transients (bursts)
          6.11.2 Surge transients
    6.12 Electromagnetic field
    6.13 Electrostatic discharge
    6.14 Static magnetic field (fraud protection)
    6.15 Electromagnetic field at mains frequency
    6.16 Internal pressure
    6.17 Pressure loss
    6.18 Electromagnetic emission
          6.18.1 Conducted emission on power a.c. lines
          6.18.2 Conducted emission on signal and d.c.
                  power lines
          6.18.3 Radiated emission
7 Documentation

This European Standard specifies pattern approval tests for heat meters

Committee
CTN 82/SC 3
DocumentType
Standard
Pages
58
PublisherName
Asociacion Espanola de Normalizacion
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
SN EN 1434-4 : 2016 Identical
NBN EN 1434-4 : 2015 Identical
ONORM EN 1434-4 : 2016 Identical
BS EN 1434-4 : 2015 Identical
NEN EN 1434-4 : 2015 Identical
NS EN 1434-4 : 1997 Identical
UNI EN 1434-4 : 2007 Identical
I.S. EN 1434-4:2015 Identical
NF EN 1434-4 : 2016 Identical
EN 1434-4:2015 Identical

EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
OIML D 11 : 2013 GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
ISO 4064-3:2014 Water meters for cold potable water and hot water — Part 3: Test report format
ISO 4064-2:2014 Water meters for cold potable water and hot water Part 2: Test methods
EN ISO 4064-2:2017 Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014)
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 60068-3-8:2003 Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
IEC 60068-3-8:2003 Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests
EN 60751:2008 INDUSTRIAL PLATINUM RESISTANCE THERMOMETERS AND PLATINUM TEMPERATURE SENSORS
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
CEN/TR 16911:2015 Heat meters - Recommendations for circulation water in industrial and district heating systems and their operation
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 60751:2008 Industrial platinum resistance thermometers and platinum temperature sensors
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 1434-1:2015 Heat meters - Part 1: General requirements
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.