Foreword
1 Scope
2 Normative references
3 General
4 Requirements
5 Specification of operating conditions
5.1 Rated operating conditions
5.2 Reference conditions
5.3 Reference values for the measurand, RVM
5.3.1 Reference values for the measurand
RVM for qp><-3,5 m3/h
5.3.2 Reference values for the measurand
RVM for qp>3,5m3/h
6 Tests and measurements
6.1 General
6.2 Test programme
6.3 Uncertainty of test equipment
6.4 Performance test
6.4.1 Flow sensor
6.4.2 Calculator
6.4.3 Temperature sensors
6.4.4 Combined sub-assemblies or complete meter
6.5 Dry heat
6.5.1 Calculator
6.5.2 Flow sensor
6.5.3 Combined sub-assemblies or complete meter
6.6 Cold
6.6.1 Calculator
6.6.2 Flow sensor
6.6.3 Combined sub-assemblies or complete meter
6.7 Static deviations in supply voltage
6.8 Durability test
6.8.1 Flow sensor
6.8.2 Temperature sensors
6.8.3 Combined sub-assemblies or complete meter
6.9 Damp heat cyclic
6.10 Short time mains voltage reduction
6.11 Electrical transients
6.11.1 Fast transients (bursts)
6.11.2 Surge transients
6.12 Electromagnetic field
6.13 Electrostatic discharge
6.14 Static magnetic field (fraud protection)
6.15 Electromagnetic field at mains frequency
6.16 Internal pressure
6.17 Pressure loss
6.18 Electromagnetic emission
6.18.1 Conducted emission on power a.c. lines
6.18.2 Conducted emission on signal and d.c.
power lines
6.18.3 Radiated emission
7 Documentation
This European Standard specifies pattern approval tests for heat meters
Committee |
CTN 82/SC 3
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 1434-4 : 2016 | Identical |
NBN EN 1434-4 : 2015 | Identical |
ONORM EN 1434-4 : 2016 | Identical |
BS EN 1434-4 : 2015 | Identical |
NEN EN 1434-4 : 2015 | Identical |
NS EN 1434-4 : 1997 | Identical |
UNI EN 1434-4 : 2007 | Identical |
I.S. EN 1434-4:2015 | Identical |
NF EN 1434-4 : 2016 | Identical |
EN 1434-4:2015 | Identical |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
OIML D 11 : 2013 | GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO 4064-3:2014 | Water meters for cold potable water and hot water — Part 3: Test report format |
ISO 4064-2:2014 | Water meters for cold potable water and hot water Part 2: Test methods |
EN ISO 4064-2:2017 | Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014) |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
IEC 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
EN 60751:2008 | INDUSTRIAL PLATINUM RESISTANCE THERMOMETERS AND PLATINUM TEMPERATURE SENSORS |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
CEN/TR 16911:2015 | Heat meters - Recommendations for circulation water in industrial and district heating systems and their operation |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 60751:2008 | Industrial platinum resistance thermometers and platinum temperature sensors |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 1434-1:2015 | Heat meters - Part 1: General requirements |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.