UNE-EN 15058:2017
Current
The latest, up-to-date edition.
Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
Hardcopy , PDF
Spanish, Castilian, English
29-11-2017
This European Standard specifies the standard reference method (SRM) based on the infra-red (IR) absorption principle. It includes the sampling and the gas conditioning system, and allows the determination of the carbon monoxide CO in flue gases emitted to the atmosphere from ducts and stacks.This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by measuring systems using the IR measurement method. It applies for periodic monitoring and for the calibration or control of automatic measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes. This European Standard specifies criteria for demonstration of equivalence of an alternative method (AM) to the SRM by application of prEN 14793.This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion plants and on a recognized test bench. It has been validated for CO concentrations with sampling periods of 30 min in the range of 0 mg/m3 to 400 mg/m3 for large combustion plants and 0 mg/m3 to 740 mg/m3 for waste and co-incineration. Directive 2010/75/EC lays down emission values which are expressed in mg/m3, on dry basis at a specified value of oxygen and at standard conditions of 273 K and 101,3 kPa.NOTE The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex A.
| Committee |
CTN 77/SC 2
|
| DocumentType |
Standard
|
| Pages |
55
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| NF EN 15058 : 2017 | Identical |
| NEN EN 15058 : 2017 | Identical |
| BS EN 15058:2017 | Identical |
| NBN EN 15058 : 2006 | Identical |
| EN 15058:2017 | Identical |
| DIN EN 15058:2006-09 | Identical |
| I.S. EN 15058:2017 | Identical |
| NS EN 15058 : 2017 | Identical |
| ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
| ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
| EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
| EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
| ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
| EN 14790:2017 | Stationary source emissions - Determination of the water vapour in ducts - Standard reference method |
| EN 15267-4:2017 | Air quality - Certification of automated measuring systems - Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources |
| ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
| EN 14793:2017 | Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.