• Shopping Cart
    There are no items in your cart

UNE-EN 61000-6-5:2016

Current

Current

The latest, up-to-date edition.

Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian, English

Published date

04-05-2016

€115.20
Excluding VAT

This part of IEC 61000 specifies EMC immunity requirements which apply to electrical and electronic equipment intended for use in power stations and substations, as described below. Immunity requirements for electromagnetic phenomena with spectral contributions in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies or for phenomena where no requirements are specified. This international standard sets immunity test requirements for equipment intended for use in the generation, transmission and distribution of electricity and related telecommunication systems. The electromagnetic environments encompassed by this standard are those which exist at locations " in power stations, and " in high and medium voltage substations. Installations to generate or convert into electrical power inside other industrial facilities are also covered by this standard as long as they, at their primary electrical connection, cannot be directly connected to the LV power network, e.g. where the generator output voltage is medium voltage or higher. NOTE 1 -In general, power stations comprise installations which are mainly built to convert some kind of primary energy into electrical energy. Moreover, these power stations are connected to the medium or high voltage power system directly or via a step-up transformer. Installations which are in addition to other primary functions (like photovoltaic cells or combined heat power systems in private houses and which are connected to the low voltage network) are not covered by this standard. The object of this standard is to define immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges.The immunity test requirements are given on a port-by-port basis, and selected according to the location, with differentiated levels for equipment to be installed in power stations or substations. In special cases, situations will arise where the level of electromagnetic disturbances may exceed the levels specified in this standard; in these instances, special mitigation measures shall be adopted. The immunity requirements are suitable for satisfying the particular needs related to the functions and tasks of equipment and systems, for which reliable operation is required under realistic electromagnetic conditions; in this respect, this standard establishes performance criteria for different functional requirements. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. According to IEC Guide 107, this generic standard shall be considered for the preparation or revision of any EMC standard referring to specific products used in power stations and substations. NOTE 2 -Product standards covering EMC aspects for equipment to be used in power stations or substations are for example IEC 62271-1 (Switchgear and controlgear) or IEC 60255-26 (Measuring relays and protection equipment). Non-electronic high voltage and power equipment (primary system) are excluded from the scope of this standard. Emission requirements are not within the scope of this standard and are covered by relevant product or product-family standards. NOTE 3 -Where no dedicated product or product family standard covering emission requirements exists, the generic standard IEC 61000-6-4 applies.

Committee
CTN 208/SC 77-210
DocumentType
Standard
Pages
50
PublisherName
Asociación Española de Normalización
Status
Current

Standards Relationship
EN 61000-6-5:2015 Identical
IEC 61000-6-5:2015 Identical

IEC 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
IEC 61800-3:2017 Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods
EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61812-1:2011 Time relays for industrial and residential use - Part 1: Requirements and tests
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60870-2-1:1995 Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC TR 61000-5-2:1997 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling
IEC TR 61000-2-5:2017 Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC TR 61000-1-6:2012 Electromagnetic compatibility (EMC) - Part 1-6: General - Guide to the assessment of measurement uncertainty
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences
IEC 60255-1:1967 Electrical relays - Part 1: Instantaneous all-or-nothing relays
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN 61000-4-34:2007/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-34: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS FOR EQUIPMENT WITH MAINS CURRENT MORE THAN 16 A PER PHASE
EN 61000-4-4:2012 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 61000-4-16:2016 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
IEC 60255-26:2013 Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirements
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 61000-4-17:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-17: TESTING AND MEASUREMENT TECHNIQUES - RIPPLE ON D.C. INPUT POWER PORT IMMUNITY TEST
IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
IEC 61000-4-34:2005+AMD1:2009 CSV Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase
EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC TR 61000-5-1:1996 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication
CISPR TR 18-1:2010 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 1: Description of phenomena

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

€115.20
Excluding VAT